FMR67 Product Overview
FMR67 is a radar level transmitter used for continuous measurement of liquid, slurry, and solid powder levels. It adopts 80GHz frequency-modulated continuous wave technology and is suitable for high-temperature, high-pressure, and corrosive working conditions.
The instrument is typically used in the chemical, petroleum, water treatment, and food industries, with a measuring range of up to 30 meters and an accuracy of ±2mm.
Core Features
- High-frequency 80GHz: Small beam angle, suitable for installation in narrow containers.
- Non-contact measurement: Not affected by medium density or viscosity.
- Diverse process connections: Supports threaded, flanged, and sanitary connections.
- Output signals: 4-20mA HART, PROFIBUS PA, Modbus, etc.
Technical Parameters and Selection
During selection, it is necessary to confirm the process temperature, pressure, dielectric constant, and explosion-proof rating. The table below lists the key parameters of the FMR67 for procurement and design reference.
Main Technical Parameters
| Parameter | Value |
|---|---|
| Measuring principle | Frequency-modulated continuous wave radar |
| Frequency | 80 GHz |
| Measuring range | 0.2 ~ 30 m |
| Accuracy | ±2 mm |
| Process temperature | -40 ~ +200°C |
| Process pressure | -1 ~ +40 bar |
| Protection class | IP66/IP68 |
| Explosion-proof certification | Ex ia IIC T6 Ga |
Selection Steps
- Confirm the medium dielectric constant (εr≥1.8).
- Determine the process connection size and type.
- Select the output signal and power supply.
- Check the explosion-proof and protection ratings.
- Refer to the FMR67 Chinese manual to confirm the installation spacing.
Installation and Commissioning Points
Correct installation can avoid false echoes. It is recommended to install the instrument vertically on the top of the container and keep the distance from the tank wall greater than the beam radius.
Installation Precautions
- Avoid installing directly above the feed inlet.
- There must be no protrusions on the flange sealing surface.
- For stirred containers, install a still pipe or waveguide.
- Outdoor installation requires a sunshade.
Commissioning Process
- After power-on, wait for the instrument self-test to complete.
- Connect via HART communicator or commissioning software.
- Enter the empty tank and full tank calibration values.
- Observe the echo curve and suppress interference echoes.
- Save the parameters and record them.
Common Problems and Maintenance
Regularly check the antenna for scaling. Use a soft cloth and neutral cleaner when cleaning. If the measured value jumps, first check the power supply and grounding.
- No signal: Check the fuse and wiring polarity.
- Value too high: There may be multiple echoes; adjust the threshold.
- Value too low: Antenna contamination or change in dielectric constant.
For more details, please refer to the fault code table in the FMR67 Chinese manual.