CLD134 Chinese Manual Download

You can directly click the link below to download the CLD134 Chinese manual (PDF format) and obtain the complete operation, installation, and maintenance guide.

CLD134 Chinese Manual DownloadDownload CLD134 Chinese Manual.pdf

CLD134 Product Overview

CLD134 is a high-precision conductivity transmitter used for industrial process control, supporting multiple conductivity cell constants and temperature compensation methods. Its compact design is suitable for online conductivity measurement in water treatment, chemical, pharmaceutical, and other industries.

Core Features

  • Wide measuring range: 0.01 µS/cm to 2000 mS/cm, covering ultrapure water to high-concentration acid-base solutions.
  • High protection rating: IP67 protection, suitable for harsh on-site environments.
  • Multiple outputs: 4-20 mA, Modbus RTU, and relay outputs optional.
  • Temperature compensation: Automatic or manual temperature compensation, supporting Pt1000 temperature sensors.

Technical Parameters

The table below lists the main technical specifications of the CLD134 for reference in model selection and engineering configuration.

ParameterSpecification
Measuring range0.01 µS/cm ~ 2000 mS/cm
Accuracy±0.5% of reading
Temperature compensationAutomatic/Manual, Pt1000
Output signal4-20 mA, Modbus RTU, relay
Power supply24 VDC or 100-240 VAC
Protection ratingIP67
Operating temperature-20°C ~ 60°C

Installation Steps

Correct installation is the prerequisite for ensuring the measurement accuracy of the CLD134. Please operate according to the following steps:

  1. Confirm that the installation location has no strong vibration or corrosive gases, and reserve sufficient maintenance space.
  2. Install the conductivity cell on the pipeline or immersion bracket, ensuring the electrode is fully immersed and free of bubbles.
  3. Connect the temperature sensor (Pt1000) to the corresponding terminal, paying attention to polarity.
  4. Connect the power supply and output signal lines according to the wiring diagram, and tighten the cable gland to achieve IP67 protection.
  5. After power-on, enter the menu and set the conductivity cell constant, temperature compensation mode, and output range.

Model Comparison

To meet the needs of different working conditions, the CLD134 provides multiple configuration options. The table below compares the differences among common models.

ModelConductivity cell constantOutputTypical application
CLD134-010.01 cm⁻¹4-20 mAUltrapure water
CLD134-100.1 cm⁻¹4-20 mA + ModbusPure water/drinking water
CLD134-201.0 cm⁻¹4-20 mA + relayGeneral water treatment
CLD134-3010 cm⁻¹Modbus RTUHigh-concentration acid-base

Maintenance and Calibration

Regular maintenance can extend the service life of the CLD134 and maintain measurement accuracy. It is recommended to calibrate every 3-6 months.

  • Use standard conductivity solutions for calibration, and rinse the electrode with deionized water before calibration.
  • Check whether there is dirt or scaling on the electrode surface, and clean it with a soft cloth and diluted acid if necessary.
  • Confirm that the cable seal is not damaged to prevent moisture from entering the transmitter.
  • Record calibration data for traceability and trend analysis.

Frequently Asked Questions

1. What should I do if the measured value fluctuates greatly?

Check whether the electrode is fully immersed and whether there are bubbles, and confirm that the temperature compensation setting is correct. If it still fluctuates, try changing the conductivity cell constant or recalibrating.

2. How do I troubleshoot abnormal output signals?

First confirm whether the power supply voltage is within the rated range, then check whether the output load matches. For 4-20 mA output, ensure that the loop resistance does not exceed the allowable value.

3. What if the manual cannot be opened after download?

Please confirm that a PDF reader has been installed. If the file is damaged, you can download it again or contact technical support.

The above is the download entry and technical key points analysis for the CLD134 Chinese manual. For more detailed wiring diagrams, menu structure, or fault codes, please download the complete PDF manual.