CUS50D Ultrasonic Flowmeter Overview

CUS50D is a high-performance ultrasonic flowmeter, widely used for flow measurement in industrial fields such as water treatment, chemical engineering, and petroleum. Its non-contact measurement method avoids pipeline pressure loss and is suitable for various pipe diameters and media. This Chinese manual is intended to help users correctly install, debug, and maintain the instrument.

CUS50D Chinese Manual PDF Icon

Click the icon above to download the complete CUS50D Chinese Manual.pdf and obtain detailed technical information.

Product Features and Working Principle

Main Features

  • High-precision measurement: Uses the time-difference method principle, with accuracy up to ±1%.
  • No obstruction components: Does not affect the fluid state in the pipeline and has no pressure loss.
  • Wide turndown ratio: Suitable for both low-flow and high-flow scenarios.
  • Multiple outputs: Supports 4-20mA, pulse, and RS485 communication.

Working Principle

The ultrasonic flowmeter uses a pair of sensors to alternately transmit and receive ultrasonic signals, and calculates the fluid flow velocity by using the time difference between downstream and upstream propagation. Combined with the pipeline cross-sectional area, the instantaneous flow rate and cumulative flow are finally obtained.

Technical Parameters

The following are the main technical specifications of the CUS50D for selection reference.

ParameterSpecification
Measurement principleTime-difference method
Accuracy class±1%
Pipe diameter rangeDN15~DN6000
Flow velocity range0~±32 m/s
Output signal4-20mA, pulse, RS485
Power supply24VDC or 220VAC
Protection classIP65 (sensor IP68 optional)

Installation Steps

Correct installation is the key to ensuring measurement accuracy. Please follow the steps below.

  1. Select the installation location: Ensure sufficient straight pipe sections (10D upstream and 5D downstream), and avoid disturbance sources such as pumps and valves.
  2. Prepare the pipe surface: Grind and clean the installation area, removing paint and rust.
  3. Install the sensors: Apply coupling agent, and attach the sensors tightly to the pipe wall and secure them.
  4. Wiring: Connect the power and signal cables according to the manual, and pay attention to grounding the shielding layer.
  5. Parameter setting: Enter parameters such as pipe diameter, wall thickness, and medium to complete calibration.
CUS50D Installation Diagram

Maintenance and Troubleshooting

Daily Maintenance

  • Regularly check whether the sensor coupling agent has dried out, and replenish it in time.
  • Clean dirt on the sensor surface to maintain signal strength.
  • Check whether the wiring terminals are loose to avoid signal interference.

Common Fault Handling

Fault PhenomenonPossible CauseSolution
No signalSensor not connected properly or coupling agent ineffectiveReinstall and apply coupling agent
Large reading fluctuationBubbles in the pipeline or insufficient straight pipe sectionVent air or adjust the installation position
Decreased accuracyIncorrect parameter settingsRe-enter pipeline parameters and calibrate

Download Chinese Manual

For more detailed operating instructions, wiring diagrams, and communication protocols, please download the complete version of the CUS50D Chinese Manual.pdf.

Download CUS50D Chinese Manual Click to download: CUS50D Chinese Manual.pdf