You can directly download the CA80AM ammonia nitrogen measurement Chinese manual to obtain complete installation, operation, and maintenance guidance.
Download CA80AM Chinese Manual.pdf
Product Overview
CA80AM is an online analyzer for continuous measurement of ammonia nitrogen concentration in water, widely used in wastewater treatment, surface water monitoring, and industrial process control.
The instrument uses the ammonia gas sensing electrode method or colorimetric method (refer to the manual for details), featuring automatic calibration, automatic cleaning, and fault alarm functions, suitable for long-term unattended operation.
Technical Parameters
The following are the main technical specifications of the CA80AM ammonia nitrogen analyzer for model selection and procurement reference.
| Parameter | Specification |
|---|---|
| Measurement Range | 0.05~1000 mg/L (segmented) |
| Measurement Accuracy | ±2% FS or ±0.05 mg/L |
| Repeatability | ≤1.5% |
| Response Time | T90 ≤ 3 minutes |
| Output Signal | 4-20 mA, RS485 Modbus |
| Protection Rating | IP65 (transmitter) |
| Power Supply | 220V AC ±10%, 50Hz |
Installation and Commissioning
Installation Steps
- Select a flat, vibration-free wall or bracket for mounting the transmitter.
- Connect the sampling tube to the analyzer inlet, ensuring no leakage.
- Connect power and signal cables, ensuring reliable grounding.
- Turn on the power and preheat for 30 minutes.
Commissioning Points
- Use standard solutions for zero calibration and span calibration.
- Set appropriate measurement cycle and cleaning interval.
- Check if the peristaltic pump tube is aged and replace if necessary.
Routine Maintenance and Troubleshooting
Regular maintenance ensures long-term stable operation of the CA80AM. Monthly inspections are recommended.
- Reagent Replacement: Regularly replace ammonia nitrogen reagents as required by the manual to avoid expiration.
- Electrode Cleaning: If using the electrode method, wipe the sensitive membrane with a soft cloth to avoid scratches.
- Tubing Cleaning: Clean the sampling tubing quarterly to prevent blockages.
- Common Faults: For reading drift or frequent alarms, first check reagents and electrodes, then contact the manufacturer.
Precautions
- Be sure to read the CA80AM Ammonia Nitrogen Measurement Manual before operation.
- Reagents are corrosive; wear protective gloves and goggles during operation.
- Dispose of waste reagents and waste liquid in accordance with local environmental regulations.