Nr

Order code

Specification

31

71323009

Power supply assembly

Usage:

Promag/Promass/Prosonic Flow/

t-mass/Teqwave MW 300/500 digital,

Non-haz, Zone 2,

transmitter housing,

electronic compartment.

47

71323013

Main electronics connection board assembly, non-hazardous, 500 digital

Usage:

Promag/Promass/Prosonic Flow/

t-mass/Teqwave MW 500 digital,

transmitter housing,

electronic compartment.

47

71323014

Main electronics connection board assembly, Ex, Promag 500 digital

Usage:

Promag/Prosonic Flow 500 digital,

transmitter housing,

electronic compartment.

36

71434751

Kit ISEM extender, 500 digital, Ex

Usage:

Prosonic Flow 500 digital,

Sensor connection housing.

33

XPD0048-

ISEM electr.mod., Prosonic Flow G 300/500

Usage:

Prosonic Flow G 300/500.

Valid for all approvals.

AA

00

39

71185788

T-DAT module

34

XPD0037-

I/O module

Usage:

Proline 300/500

AA

A1

F1

01

46

71459753

Kit ISEM ribbon cable, 500 digital

Usage:

Prosonic Flow 500 digital,

sensor connection housing.

35

XPD0038-

I/O module

Usage:

Proline 300/500

AA

1A

1C

1D

00

50

XPD0031-

Display module

Usage:

Proline 300/500, DKX001.

BA

A

F

G

00

45

71323077

Terminal assembly

Usage:

transmitter housing Alu/polycarbonate,

connection compartment.

Option A =

HART, PROFIBUS PA, FOUNDATION Fieldbus.

Consists of:

1x connection terminal 2-pole,

1x connection terminal 3-pole,

1x connection terminal 4-pole,

1x connection terminal 6-pole.

45

71327820

Terminal assembly

Usage:

transmitter housing Alu/polycarbonate,

connection compartment.

Option C =

PROFIBUS DP, Modbus RS485.

Consists of:

1x connection terminal 2-pole,

1x connection terminal 3-pole,

1x connection terminal 4-pole,

1x connection terminal 6-pole.

20

71384170

Promag 400/500 cover

Usage:

Prosonic Flow 400, Promag 400(C),

(C) = generation index C,

Promag/Promass/Prosonic Flow/t-mass/

Teqwave MW 500 digital,

transmitter housing Alu.

Consists of:

cover Alu complete included

O-Ring 196.40x3.53 HNBR,

default and -50oC/-58oF,

wire with screw lock 1.5x150.

20

71408508

Cover

Usage:

Prosonic Flow 400,

Promag/Promass/Prosonic Flow/t-mass/

Teqwave MW 500 digital, Promag 800(C),

(C) = generation index C,

transmitter housing polycarbonate.

Consists of:

cover polycarbonate complete,

O-Ring 196.44x3.53 VMQ,

default and -50oC/-58oF,

wire with screw lock 1.5x150.

70

71278078

Cover seal ring

Usage:

Prosonic Flow 400, Promag 400(C),

(C) = generation index C,

Promag/Promass/Prosonic Flow/t-mass/

Teqwave MW 500 digital,

transmitter housing Alu.

Consists of:

10x O-Ring 196.40x3.53 HNBR,

default and -50oC/-58oF.

70

71278077

Cover polycarbonate gasket

Usage:

Prosonic Flow 400,

Promag/Promass/Prosonic Flow/t-mass/

Teqwave MW 500 digital,

Promag 400/800(C),

(C) = generation index C,

transmitter housing polycarbonate.

Consists of:

10x O-Ring 196.44x3.53 VMQ.

24

71228796

Cover assembly

Usage:

Promag 10/500,

Promag/Promass/Prosonic Flow/t-mass/

Teqwave MW 500 digital,

Promag 400/800(C),

(C) = generation index C,

sensor connection housing.

Consists of:

cover Alu,

O-Ring 113.90x3.53 HNBR.

24

71323050

Cover assembly

Usage:

Promass/Prosonic Flow/t-mass 500 digital,

sensor connection housing.

Consists of:

cover Alu,

O-Ring 113.90x3.53 FVMQ, -50oC/-58oF.

73

71323051

Housing seal ring assembly

Usage:

Promass/Prosonic Flow/t-mass 500 digital,

sensor connection housing.

Consists of:

O-Ring 113.90x3.53 HNBR for cover,

gasket EPDM for housing/sensor.

73

71323052

Housing seal ring assembly

Usage:

Promass/Prosonic Flow/t-mass 500 digital,

sensor connection housing.

Consists of:

O-Ring 113.90x3.53 FVMQ for cover,

-50oC/-58oF,

gasket FVMQ for housing/sensor,

-50oC/-58oF.

24

71323063

Cover assembly

Usage:

Promag/Promass 500,

Promag/Promass/Prosonic Flow/t-mass

500 digital, sensor connection housing.

Consists of:

cover cast,

O-Ring 120.2x3.53 HNBR.

24

71323064

Cover assembly

Usage:

Promass 500,

Promass/Prosonic Flow/t-mass 500 digital,

sensor connection housing.

Consists of:

cover cast,

O-Ring 120.2x3.53 FVMQ, -50oC/-58oF.

73

71323065

Housing seal ring assembly

Usage:

Promass 500,

Promass/Prosonic Flow/t-mass 500 digital,

sensor connection housing.

Consists of:

O-Ring 120.2x3.53 HNBR for cover,

O-Ring 88.50x3.53 HNBR for housing/sensor

73

71323066

Housing seal ring assembly

Usage:

Promass 500,

Promass/Prosonic Flow/t-mass 500 digital,

sensor connection housing.

Consists of:

O-Ring 120.2x3.53 FVMQ for cover,

-50oC/-58oF,

O-Ring 88.50x3.53 FVMQ for hous./sensor,

-50oC/-58oF.

13

71276494

Clamp fastening, screw

Usage: Promass 100, Promag 100,

Prosonic Flow E 100/E Heat,

CNGmass, LPGmass, LNGmass,

Promag/Promass 500, Promag 10,

Promag/Promass/Prosonic Flow/t-mass/

Teqwave MW 500 digital,

Promag 400/800(C),

(C) = generation index C,

sensor connection housing.

Consists of:

cover clamp, screw M4x16.

71450719

Adapter M12, RJ45, L= 80mm (suitable for t-mass F 300/50

Usage:

Proline 300/500.

82

71228792

Display protection cover

Usage:

Prosonic Flow 400, Promag 400(C),

(C) = generation index C,

Promag/Promass/Prosonic Flow/t-mass/

Teqwave MW 500 digital,

transmitter housing Alu.

Consists of:

display protection 1.4301,

installation material.

87

71343504

Protective housing assembly

Usage:

Promag/Promass/Prosonic Flow/t-mass/

Teqwave MW 400/800/500 digital,

transmitter housing.

Consists of:

weather protection cover 4404.

71346427

Pipe mounting assembly

For Product:

Promag 500 digital

Promass 500 digital

t-mass 500 digital

Prosonic Flow 500 digital

Teqwave MW 500 digital

Prosonic Flow 400

71351317

Wireless receiver for extended distance

Consists of:

Connection cable in the transmitter,

Ex cable entry for antenna,

1.5m cable,

antenna,

angle with union nut.

9X5BXX-

Transmitter ultrasonic flowmeter Flow 500, 9X5BXX

With an integrated web server.

AA

BJ

BL

BN

BS

C6

CN

CS

CZ

GJ

GL

GN

GR

GS

JD

JJ

KN

MJ

ML

MN

MS

NJ

NL

NN

NS

UJ

UL

UN

UR

US

9

I

99

BA

MA

9

A

B

D

E

F

H

I

J

9

A

B

D

E

F

H

I

J

9

A

B

D

E

H

I

J

9

F

G

9

A

9

A

D

9

A

B

E

F

J

L

6

9

A

B

C

D

AA

00

99

00

99

A2

AA

AB

AC

AD

AE

AF

AG

AH

AI

AJ

AK

AL

AM

AQ

AR

AT

I7

I9

JP

K9

L9

LA

N9

NB

P7

P9

PB

PV

73

74

76

78

Z1

Z2

DK9012-

Prosonic Flow 500, sensor cable

Connection Cable

between Sensor Junction

Housing and Transmitter for Remote

Devices of Proline 500.

AA

BJ

BL

BN

BS

C6

CN

CS

CZ

GJ

GL

GN

GR

GS

JJ

KN

MJ

ML

MN

MS

NJ

NL

NN

NS

UJ

UL

UN

UR

US

A

9

A

L

9

B

E

F

J

L

GA

00

JP

K9

XPRFID-

Spare RFID TAG

Consists of:

RFID TAG, fixing wire, crimp sleeve.

AA

BA

CA

IA

KA

MA

NA

UA

UR

1