Nr

Order Number

Specification

31

71484378

Kit power supply,100-240VAC/19-30VDC

Usage:

Promag 800(C),

(C) = generation index C,

transmitter housing.

40

71484379

Kit connec. board external power supply

Usage:

Promag 800(C),

(C) = generation index C,

transmitter housing.

41

71484380

Kit connection board I/O-modules, 800(C)

Usage:

Promag 800(C),

(C) = generation index C,

transmitter housing.

30

XPD0055-

Electronic insert, advanced input/output option I, 800(C)

Usage:

Promag 800(C),

(C) = generation index C,

Adv. = Functionality: Transmitter

Advanced.

Consists of:

Main electronic (amplifier and I/O),

Display.

AA

1A

1C

1I

1J

00

78

38

71484382

Kit S+T-DAT, compact, Promag 800(C)

Electronic storage module unprogrammed

Usage:

Promag 800(C),

(C) = generation index C.

Consists of:

S+T-DAT.

30

XPD0056-

Electronic insert, advanced input/output option M, 800(C)

Usage:

Promag 800(C),

(C) = generation index C,

Adv. = Functionality: Transmitter

Advanced.

Consists of:

Main electronic (amplifier and I/O),

Display.

AA

1A

1C

1M

1J

00

78

42

71484383

Kit connection board + S+T-DAT, remote

Electronic storage module unprogrammed

Usage:

Promag 800(C),

(C) = generation index C.

transmitter housing.

Consists of:

S+T-DAT.

30

XPD0057-

Electronic insert, advanced input/output option P, 800(C)

Usage:

Promag 800(C),

(C) = generation index C,

Adv. = Functionality: Transmitter

Advanced.

Consists of:

Main electronic (amplifier and I/O),

Display, Cellular radio module.

AA

1A

1C

1P

1J

00

77

37

71484384

Kit circuit + battery carrier, 800(C)

Usage:

Promag 800(C),

(C) = generation index C,

transmitter housing.

Consists of:

circuit carrier electronic,

support with hinge,

cover to power output,

cover to circuit carrier electronic.

46

71484385

Kit electronic-ribbon cable, 800(C)

Usage:

Promag 800(C),

(C) = generation index C,

transmitter housing.

45

71484386

Kit terminal, power supply

Usage:

Promag 800(C),

(C) = generation index C,

transmitter housing.

Consists of:

1x connecting terminal pluggable 3-Pol.,

2x connecting terminal pluggable 4-Pol.

30

XPD0058-

Electronic, Std., I/O option K, 800(C)

Usage:

Promag 800(C),

(C) = generation index C,

Std. = Functionality: Standard

transmitter.

Consists of:

Main electronics (amplifier and I/O),

Display.

Usage:

Promag 800(C),

(C) = generation index C,

Std. = Functionality: Standard

transmitter.

Consists of:

Main electronics (amplifier and I/O),

Display.

AA

1A

1A

1K

1D

00

78

45

71484387

Kit terminal, external power supply

Usage:

Promag 800(C),

(C) = generation index C,

transmitter housing.

Consists of:

2x connecting terminal pluggable 4-Pol.

30

XPD0059-

Electronic, Std., I/O option N, 800(C)

Usage:

Promag 800(C),

(C) = generation index C,

Std. = Functionality: Standard

transmitter.

Consists of:

Main electronics (amplifier and I/O),

Display.

Usage:

Promag 800(C),

(C) = generation index C,

Std. = Functionality: Standard

transmitter.

Consists of:

Main electronics (amplifier and I/O),

Display.

AA

1A

1A

1N

1D

00

78

83

71496693

Kit antenna complete, Promag 800(C)

Usage:

Promag 800(C),

(C) = generation index C,

transmitter housing.

Consists of:

antenna,

connection cable in the transmitter,

assembly material.

38

71484382

Kit S+T-DAT, compact, Promag 800(C)

Electronic storage module unprogrammed

Usage:

Promag 800(C),

(C) = generation index C.

Consists of:

S+T-DAT.

44

71615503

Terminal board

Usage:

Promag 400(C) sensor L/W non-haz,

Promag 800(C) sensor W non-haz.

(C) = generation index C,

Sensor connection housing.

Consists of: connection board.

20

71408508

Cover

Usage:

Prosonic Flow 400,

Promag/Promass/Prosonic Flow/t-mass/

Teqwave MW 500 digital, Promag 800(C),

(C) = generation index C,

transmitter housing polycarbonate.

Consists of:

cover polycarbonate complete,

O-Ring 196,44x3,53 VMQ,

default and -50oC/-58oF,

wire with screw lock 1,5x150.

70

71278077

Cover seal, polycarbonate

Usage:

Prosonic Flow 400,

Promag/Promass/Prosonic Flow/t-mass/

Teqwave MW 500 digital,

Promag 400/800(C),

(C) = generation index C,

transmitter housing polycarbonate.

Consists of:

10x O-Ring 196,44x3,53 VMQ.

24

71228796

Cover assembly

Usage:

Promag 10/500,

Promag/Promass/Prosonic Flow/t-mass/

Teqwave MW 500 digital,

Promag 400/800(C),

(C) = generation index C,

sensor connection housing.

Consists of:

cover Alu,

O-Ring 113,90x3,53 HNBR.

24

71188176

Cover assembly

Usage:

Promag 10/400/500/800,

Promag 400/800(C),

(C) = generation index C,

sensor connection housing.

Consists of:

cover plastic coated,

O-Ring 91,67 x 3,53 FKM.

24

71188176

Cover assembly

Usage:

Promag 10/400/500/800,

Promag 400/800(C),

(C) = generation index C,

sensor connection housing.

Consists of:

cover plastic coated,

O-Ring 91,67 x 3,53 FKM.

24

71188176

Cover assembly

Usage:

Promag 10/400/500/800,

Promag 400/800(C),

(C) = generation index C,

sensor connection housing.

Consists of:

cover plastic coated,

O-Ring 91,67 x 3,53 FKM.

24

71188176

Cover assembly

Usage:

Promag 10/400/500/800,

Promag 400/800(C),

(C) = generation index C,

sensor connection housing.

Consists of:

cover plastic coated,

O-Ring 91,67 x 3,53 FKM.

72

71188179

Cover seal

Usage:

Promag 10/400/500/800,

Promag 400/800(C),

(C) = generation index C,

sensor connection housing.

Consists of:

10x O-Ring 91,67 x 3,53 FKM.

72

71188179

Cover seal

Usage:

Promag 10/400/500/800,

Promag 400/800(C),

(C) = generation index C,

sensor connection housing.

Consists of:

10x O-Ring 91,67 x 3,53 FKM.

72

71188179

Cover seal

Usage:

Promag 10/400/500/800,

Promag 400/800(C),

(C) = generation index C,

sensor connection housing.

Consists of:

10x O-Ring 91,67 x 3,53 FKM.

72

71188179

Cover seal

Usage:

Promag 10/400/500/800,

Promag 400/800(C),

(C) = generation index C,

sensor connection housing.

Consists of:

10x O-Ring 91,67 x 3,53 FKM.

20

71537405

Kit cover, polycarbonate,800(C) standard

Usage:

Promag 800(C) standard,

(C) = generation index C,

standard = standard transmitter

functionality.

Transmitter housing polycarbonate.

Consists of:

Complete cover polycarbonate,

O-ring 106,00x3,53 VMQ,

3x desiccant.

70

71537406

Kit 10 cover seals,polycarb.,800(C) std.

Usage:

Promag 800(C) standard,

(C) = generation index C,

std. = standard transmitter

functionality.

Transmitter housing polycarbonate.

Consists of:

10x O-ring 106,00x3,53 VMQ.

3x desiccant.

71

71488158

Interface gasket

Usage:

Promag 800(C),

(C) = generation index C,

transmitter housing.

Consists of:

gasket VMQ for interface,

O-Ring 29,87x1,78 HNBR for sensor plug.

71

71488159

Interface gasket

Usage:

Promag 400/800(C),

(C) = generation index C,

transmitter housing polycarbonate.

Consists of:

O-ring 69,44x3,53VMQ for interface,

O-ring 29,87x1,78 HNBR for sensor plug.

71

71488158

Interface gasket

Usage:

Promag 800(C),

(C) = generation index C,

transmitter housing.

Consists of:

gasket VMQ for interface,

O-Ring 29,87x1,78 HNBR for sensor plug.

71

71488159

Interface gasket

Usage:

Promag 400/800(C),

(C) = generation index C,

transmitter housing polycarbonate.

Consists of:

O-ring 69,44x3,53VMQ for interface,

O-ring 29,87x1,78 HNBR for sensor plug.

73

71228798

Housing seal assembly

Usage:

Promag 10/500,

Promag 500 digital,

Promag 400/800(C),

(C) = generation index C,

sensor connection housing.

Consists of:

O-Ring 113,90x3,53 HNBR for cover,

gasket EPDM for

housing/sensor L/P/W,

O-Ring 29,87x1,78 HNBR for sensor plug.

73

71488160

Housing gasket assembly

Usage:

Promag 10/400/800(C),

(C) = generation index C,

sensor connection housing alu.

Consists of:

O-ring 113,90X3,53HNBR for cover,

O-ring 69,44x3,53HNBR for housing/sensor

O-ring 29,87x1,78 HNBR for sensor plug.

73

71228798

Housing seal assembly

Usage:

Promag 10/500,

Promag 500 digital,

Promag 400/800(C),

(C) = generation index C,

sensor connection housing.

Consists of:

O-Ring 113,90x3,53 HNBR for cover,

gasket EPDM for

housing/sensor L/P/W,

O-Ring 29,87x1,78 HNBR for sensor plug.

73

71488160

Housing gasket assembly

Usage:

Promag 10/400/800(C),

(C) = generation index C,

sensor connection housing alu.

Consists of:

O-ring 113,90X3,53HNBR for cover,

O-ring 69,44x3,53HNBR for housing/sensor

O-ring 29,87x1,78 HNBR for sensor plug.

13

71276494

Clamp fastening, screws

Usage: Promass 100, Promag 100,

Prosonic Flow E 100/E Heat,

CNGmass, LPGmass, LNGmass,

Promag/Promass 500, Promag 10,

Promag/Promass/Prosonic Flow/t-mass/

Teqwave MW 500 digital,

Promag 400/800(C),

(C) = generation index C,

sensor connection housing.

Consists of:

cover clamp, screw M4x16.

71555753

Kit sealing, transm./sensor, alu, cast

Usage:

Transmitter housing alu, cast:

Promag 300, 500.

Sensor housing alu, cast:

300/500/800, 500 digital.

(C) = generation index C.

Consists of:

3x securing clamps,

3x sealing screws M4x16.

71279174

Sealing ring

Usage:

Sensor housing polycarbonate:

Promag 400(C), 500, 800.

(C) = generation index C.

Consists of:

Sealing ring 1.4404.

71279174

Sealing ring

Usage:

Sensor housing polycarbonate:

Promag 400(C), 500, 800.

(C) = generation index C.

Consists of:

Sealing ring 1.4404.

71279174

Sealing ring

Usage:

Sensor housing polycarbonate:

Promag 400(C), 500, 800.

(C) = generation index C.

Consists of:

Sealing ring 1.4404.

71279174

Sealing ring

Usage:

Sensor housing polycarbonate:

Promag 400(C), 500, 800.

(C) = generation index C.

Consists of:

Sealing ring 1.4404.

71183755

Silicone IP68, Promag 400/800

Consists of:

Cartridge Silicone caoutchouc Silgel612.

Mixing tube for cartridge.

71

71488158

Interface gasket

Usage:

Promag 800(C),

(C) = generation index C,

transmitter housing.

Consists of:

gasket VMQ for interface,

O-Ring 29,87x1,78 HNBR for sensor plug.

71183755

Silicone IP68, Promag 400/800

Consists of:

Cartridge Silicone caoutchouc Silgel612.

Mixing tube for cartridge.

71183755

Silicone IP68, Promag 400/800

Consists of:

Cartridge Silicone caoutchouc Silgel612.

Mixing tube for cartridge.

71183755

Silicone IP68, Promag 400/800

Consists of:

Cartridge Silicone caoutchouc Silgel612.

Mixing tube for cartridge.

71183755

Silicone IP68, Promag 400/800

Consists of:

Cartridge Silicone caoutchouc Silgel612.

Mixing tube for cartridge.

71504536

Set battery housing, Promag 800

Usage:

External battery housing w/o Battery

Promag W 800

Transmitter Advanced

71343504

Protective housing assembly

Usage:

Promag/Promass/Prosonic Flow/t-mass/

Teqwave MW 400/800/500 digital,

transmitter housing.

Consists of:

weather protection cover 4404.

71504534

Set display protection round, Promag 800

Usage:

Promag W 800

Standard transmitter

71504535

Cable, Modbus, 3x pulse, 5m

Usage:

Connection cable for Promag W 800

Standard transmiter

MIL_DTL-2648 plug.

49

DK5016-

Battery assembly, Promag W 800 (5W8C)

A

C

A

B

C

D

5X8CXX-

Transmitter Promag 800, 5X8CXX

Battery powered Transmitter

incl. Display, data logger

AA

CP

GR

UR

9

A

C

9

H

K

Q

S

9

I

K

M

N

P

9

D

J

9

M

N

0

1

2

3

6

7

9

9

A

B

C

D

E

A1

I7

I9

N9

NC

PB

PC

PG

PI

PJ

PK

PW

R9

77

78

Z1

Z2

DK5015-

Pressure capsule, Promag 800

Usage:

Promag W 800

Transmitter Advanced

8C

99

PI

PJ

DK5CA-

Cable DK5CA for Promag 10/50/51/53/55 remote version

10/50/51/53/55/400/800

1 kit includes 1 coil cable and

1 signal cable

1

2

3

6

7

A

DK5005-

Transmitter mounting kit 400

Usage:

Promag 400/800,

transmitter advanced.

B

DK5GD-

Grounding ring DK5GD

Includes 1 grounding disc/protection

disc

1FA

1FB

1HA

1HB

1ZA

1ZB

25A

25B

2FA

2FB

2HA

2HB

32A

32B

3FA

3FB

3HA

3HB

3SA

3SB

40A

40B

4FA

4FB

4HA

4HB

50A

50B

5HA

5HB

65A

65B

6HA

6HB

7FA

7HA

80A

80B

8HA

RHA

T0A

T2A

V0A

9

E

H

U

5

7

9

A

B

C

D

E

L

M

P

T

U

DK5GC-

Grounding cable DK5GC

A kit includes 2 cables

1F

1H

1Z

25

2F

2H

32

3F

3H

40

50

65

80

0

5

7

A

B

C

D

L

M

T

U

XPRFID-

Spare RFID TAG

Consists of:

RFID TAG, fixing wire, crimp sleeve.

AA

CA

UR

1