Promag 10D Electromagnetic Flowmeter Spare Parts Overview

Promag 10D is an electromagnetic flowmeter in the Proline series under Endress+Hauser, widely used in industrial flow measurement. This article compiles a list of commonly used spare parts, including order numbers, specifications, and applicable models, to facilitate engineering maintenance and procurement selection.

Spare parts are divided into four major categories by function: electronic modules, terminal components, housing and seals, and installation accessories. Some spare parts are available in HE (harsh environment, harsh environment) versions, suitable for harsh environments.

Electronic Modules and Display Spare Parts

PCB Mainboard

The PCB mainboard is the core component of the transmitter, responsible for signal processing and output. The following models are available:

Order NumberSpecificationRemarks
50104751PCB MainboardStandard
50104752PCB MainboardStandard
71098237PCB MainboardHE = harsh environment
71098239PCB MainboardHE = harsh environment

Fuses

  • 50104749: Fuse, standard
  • 50104750: Fuse, standard

Display Module

  • 50104745: Display module with buttons, for on-site operation and reading

Terminal Components and Sensor Connection

Terminal Module

Order NumberSpecificationRemarks
50104754Terminal ModuleStandard
71098240Terminal ModuleHE = harsh environment

Sensor Terminal Board

The sensor terminal board is used to connect the sensor and transmitter. When selecting, pay attention to the applicable models:

  • 50098018: Applicable to 10/50/51/53/55/400/800
  • 71039497: Applicable to 10/50/53/55, HE = harsh environment

Terminals and Cable Glands

  • 50108138: Terminal, Kit Terminal Block 10/91W
  • 50103658: Cable gland
  • 50096840: Cable gland, Kit 10 cable glands M20x1,5
  • 50098041: Adapter, Kit 10 extension M20x1.5/G 1/2"
  • 50098042: Adapter, Kit 10 extension M20x1.5/NPT 1/2"

Housing, Covers, and Seals

Terminal Compartment Cover and Repair Cover

Order NumberSpecificationApplicable Models/Remarks
50094038Terminal compartment cover10/5X/40/8X/93/65/92F
71247838Repair cover, remote version10/5X/8X/8DF/8CN/92F/65/400/800; includes Cover Rep.kit for G14, O-Ring 110.00 x 4.50 HNBR, Grease; according to service information SI01351D-1/06
50094038Terminal compartment cover10/5X/40/8X/93/65/92F

Meter Cover and Window

  • 50104746: Meter cover with glass window
  • 50104747: Blind cover
  • 50104753: Meter cover seal

Housing Components and Gaskets

Order NumberSpecificationApplicable Models/Sensor
50099102Cast aluminum/stainless steel housing sleeve
50098019Kit parts housing FS Stnd/HT10/50/51/53/55/400/800; Sensor: D/E/H/L/P/S/W
50098020Kit parts housing compact Stnd/HT10/23/50/51/53/55; Sensor: D/E/H/L/P/S/W
50098023Housing gasket kit10/50/51/53/55/400/800; Sensor: D/E/L/P/S/W
50098024Housing gasket kit10/23/50/51/53/55; Sensor: D/E/L/P/S/W

Other Accessories

  • 50104748: Display module bracket
  • 50097147: Ground terminal/cover locking clip, applicable to 10/1YH/23/65/72/73/91W/92F/8FF/8FE/8CM

Installation Accessories and Special Kits

Promag D Installation Kit

  • DKD-: Promag D installation kit, including threaded bolts, centering sleeves, nuts, washers, and a pair of EPDM flange seals. Can be ordered separately as replacement for M1, M2.
  • DK5DD-: Promag D seal kit, one set includes 2 flange seals.

Cable and Transmitter Kits

  • DK5CA-: Promag cable remote version, applicable to 10/50/51/53/55/400/800. 1 set includes 1 coil cable and 1 signal cable.
  • DK5WM-: Transmitter Promag installation kit, applicable to 10/50/51/53/55/800.

Service Interface

  • FXA193-: Service interface FXA193, used to connect the service port of Proline and ToF devices to the RS 232C serial port (9-pin) of a PC. Delivery contents: service interface with RS 232C connection cable (9-pin), FXA "USB" cable, and additional power supply to power FXA193 from the PC USB port.

Selection and Procurement Recommendations

When purchasing spare parts, be sure to verify the instrument model, sensor type, and environmental requirements. If the site has corrosive, humid, or extreme temperature conditions, it is recommended to prioritize HE (harsh environment) version spare parts.

For components such as repair covers, refer to service information SI01351D-1/06 to ensure all necessary parts (such as O-rings and grease) are included.

It is recommended to confirm order numbers with Endress+Hauser authorized distributors or official channels to avoid incompatibility due to model updates.