Nr

Order number

Specification

34

71108602

I/O module

Non-Ex, Ex.

Current output, 4-20mA HART + 4-20mA

analog.

Usage: FTM50/FTM51/FTM52.

Usage: Promass 200/TB2,

Prosonic Flow 200, Prowirl 200.

34

71164940

I/O module

Non-Ex, Ex.

PROFIBUS PA, FOUNDATION Fieldbus.

PFS=switch output.

Version 2.

Usage: FMP50/FMP51/FMP52/FMP53/

FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/

FMR52/FMR53/FMR54/FMR56/FMR57.

Usage: Promass 200, Prowirl 200,

Promag 200.

71128617

Overvoltage protection

4-20mA HART.

Usage: FMP50/FMP51/FMP52/FMP53/

FMP54/FMP55/FMP56/FMP57,

FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/

FMR57, FMR60/FMR62/FMR67.

Usage: Promass 200, Prosonic Flow 200,

Promag 200, Prowirl 200.

71128619

Overvoltage protection

4-20mA HART, PROFIBUS PA, FOUNDATION

Fieldbus, Imp./Freq./Switch output.

Usage: FMP50/FMP51/FMP52/FMP53/

FMP54/FMP55/FMP56/FMP57,

FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/

FMR57, FMR60/FMR62/FMR67.

Usage: Promass 200, Prosonic Flow 200,

Promag 200, Prowirl 200.

71197334

Transmitter FHX50

Consists of:

electronics, ribbon cable.

Usage: FMP50/FMP51/FMP52/FMP53/

FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/

FMR52/FMR53/FMR54/FMR56/FMR57.

Usage: Promass200, Prowirl 200,

Promag 200, Prosonic Flow 200.

Remote display FHX50 please order with

separate order structure.

71296840

Plug M12, VA

To connect FHX50.

Usage:

FMP50/51/52/53/54/55/56/57,

FMR50/51/52/53/54/56/57.

Not for dust Ex.

Usage: Prowirl 200, Promass 200,

Promag 200, Prosonic Flow 200.

30

XPD0001-

Electronic Promass 200 / TB2

Main electronic module

71206552

Cable

Connection cable, shielded.

Usage: FHX50.

71206554

Cable

Connection cable, shielded.

Usage: FHX50.

71206555

Cable

Connection cable, shielded.

Usage: FHX50.

34

XPD0015-

I/O module, 2-wire, 4-20mA, HART, Ex

Non-Ex, Ex.

1x current output HART.

71206556

Cable

Connection cable, shielded.

Usage: FHX50.

37

71110280

Terminal set 2-wire, I/O module

Consists of:

4x terminal 2-pole, green.

Usage: FMP50/FMP51/FMP52/FMP53/

FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/

FMR52/FMR53/FMR54/FMR56/FMR57,

FMR60/FMR62/FMR67.

Usage: Promass 200/TB2,

Prosonic Flow 200, Promag 200,

Prowirl 200.

34

XPD0016-

I/O module, 2-wire, 4-20mA,HART, PFS, Ex

Non-Ex, Ex.

1x current output HART.

1x PFS= pulse/freq./switch output.

40

XPD0024-

Display module, SD02, push buttons

For housing: GT18, GT19, GT20.

Usage:

FMP50/51/52/53/54/55/56/57,

FMR50/51/52/53/54/56/57,

FMR60/62/67, FHX50.

Promass 200/TB2, Prosonic Flow 200,

t-mass 150, Promag 200, Prowirl 200.

Consists of:

Display SD02, helix cable,

ribbon cable, connector cover.

40

XPD0025-

Display module, SD03, Touch Control

For housing: GT18, GT19, GT20.

Usage:

FMP50/51/52/53/54/55/56/57,

FMR50/51/52/53/54/56/57,

FMR60/62/67, FHX50.

Promass 200/TB2, Prosonic Flow 200,

Promag 200, Prowirl 200.

Consists of:

Display SD03 illuminated, ribbon cable,

connector cover.

20

71110281

Aluminum cover

Material: 316L.

O-ring, EPDM, PTFE coated.

Usage: FMP51/FMP52/FMP54/FMP55/

FMP56/FMP57, FMR51/FMR52/FMR53/

FMR54/FMR57, FMR62/FMR67.

Usage: Promass 200/TB2,

Prosonic Flow 200, Prowirl 200.

20

71110282

Aluminum cover

Material: 316L.

O-ring NBR, PTFE coated.

Usage: FMP51/FMP52/FMP54/FMP55/

FMP56/FMP57, FMR51/FMR52/FMR53/

FMR54/FMR57, FMR62/FMR67, FHX50.

Usage: Promass 200/TB2,

Prosonic Flow 200, Prowirl 200.

25

71110291

Aluminum cover

Material: 316L.

O-ring EPDM, PTFE coated.

Usage: terminal compartment,

not for Ex d/XP,

FMP51/FMP52/FMP54/FMP55/FMP56/FMP57,

FMR51/FMR52/FMR53/FMR54/FMR57,

FMR62/FMR67.

Usage: Promass 200/TB2,

Prosonic Flow 200, Prowirl 200.

25

71110284

Aluminum cover

Material: 316L.

O-ring EPDM /PTFE coated.

Usage: terminal compartment Ex d/XP,

FMP51/FMP52/FMP54/FMP55/FMP56/FMP57,

FMR51/FMR52/FMR53/FMR54/FMR57,

FMR62/FMR67.

Usage: Promass 200/TB2,

Prosonic Flow 200, Prowirl 200.

25

71185516

Cover

Material: 316L.

O-ring EPDM, PTFE coated.

Usage: terminal compartment,

for overvoltage protection,

not for Ex d/XP,

FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/

FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/

FMP54/FMP56/FMP57, FMR62/FMR67.

Usage: Promass 200, Prosonic Flow 200,

Prowirl 200.

20

71110299

Aluminum cover

Material: aluminium, coated.

O-ring EPDM, PTFE coated.

Usage: FMP50/FMP51/FMP52/FMP53/

FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/

FMR52/FMR53/FMR54/FMR56/FMR57,

FMR60/FMR62/FMR67.

Usage: Promass 200/TB2,

Prosonic Flow 200, Promag 200,

Prowirl 200.

20

71110297

Aluminum cover

Material: aluminium, coated.

O-ring EPDM, PTFE coated.

Usage: FMP50/FMP51/FMP52/FMP53/

FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/

FMR52/FMR53/FMR54/FMR56/FMR57,

FMR60/FMR62/FMR67.

Usage: Promass 200/TB2,

Prosonic Flow 200, Promag 200,

Prowirl 200.

25

71110301

Aluminum cover

Material: aluminium, coated.

O-ring EPDM, PTFE coated.

Usage: terminal compartment,

not for Ex d/XP,

FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/

FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/

FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.

Usage: Promass 200/TB2,

Prosonic Flow 200, Promag 200,

Prowirl 200.

25

71110302

Aluminum cover

Material: aluminium, coated.

O-ring EPDM, PTFE coated.

Usage: terminal compartment Ex d/XP,

FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/

FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/

FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.

Usage: Promass 200/TB2,

Prosonic Flow 200, Promag 200,

Prowirl 200.

25

71185517

Aluminum cover

Material: aluminium.

O-ring EPDM, PTFE coated.

Usage: terminal compartment,

for overvoltage protection,

not for Ex d/XP,

FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/

FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/

FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.

Usage: Promass 200, Prosonic Flow 200,

Promag 200, Prowirl 200.

15

50103658

Cable gland

15

50098036

Ex cable gland

Kit 10 cable glands M20x1.5 Ex

15

71069285

Cable gland kit

15

50098041

Adapter

Kit 10 extension M20x1.5/G 1/2"

15

71115505

M20x1.5/G 1/2" adapter

15

50098042

Adapter

Kit 10 extension M20x1.5/NPT 1/2"

15

71115509

M20x1,5/NPT1/2" adapter

15

50098037

PA bus cable gland

Kit Cable gland Profibus PA

Kit 10 extension M20x1.5/PG13,5

15

50094984

FF bus cable gland

Kit Cable gland Found. Fieldbus

65

71110303

Housing seal kit

Consists of:

O-ring 88.5x3.53 EPDM/PTFE,

cover electronics compartment,

housing GT19.

O-Ring 88.5x3.53 NBR,

cover electronics compartment,

housing GT18, GT20.

O-ring 91.67x3.53 EPDM/PTFE,

cover terminal compartment,

housing GT19.

O-Ring 91.67x3.53 NBR,

cover terminal compartment,

housing GT18, GT20.

O-ring 50.39x3.53 EPDM/PTFE,

housing/sensor.

FMP50/FMP51/FMP52/FMP53/

FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/

FMR52/FMR53/FMR54/FMR56/FMR57,

FMR60/FMR62/FMR67.

Usage: Promass 200/TB2,

Prosonic Flow 200, Promag 200,

Prowirl 200.

19

71115174

Housing filter plug (304)

Consists of:

2x filter plug metall 316L.

1x pressure compensation filter.

Usage: FMP50/FMP51/FMP52/FMP53/

FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/

FMR52/FMR53/FMR54/FMR56/FMR57,

FMR62/FMR67.

Usage: Promass 200/TB2,

Prosonic Flow 200, Prowirl 200.

19

71115175

Housing filter plug (brass/nickel)

Consists of:

2x filter plug brass nickel,

pressure compensation filter.

Usage: FMP50/FMP51/FMP52/FMP53/

FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/

FMR52/FMR53/FMR54/FMR56/FMR57,

FMR60/FMR62/FMR67.

Usage: Promass 200/TB2,

Prosonic Flow 200, Promag 200,

Prowirl 200.

17

71115176

Housing mounting clamp

Usage: housing GT18/GT19/GT20,

FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/

FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/

FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.

Usage: Promass 200/TB2,

Prosonic Flow 200, Promag 200,

Prowirl 200.

71162242

Cover|GT18/GT19/GT20,316L

Usage: FMP50/FMP51/FMP52/FMP53/

FMP54/FMP55/FMP56/FMP57,

FMR50/FMR51/FMR52/FMR53/FMR54/

FMR56/FMR57, FMR60/FMR62/FMR67.

Usage: Promass 200/TB2,

Prosonic Flow 200, Promag 200, Prowirl

200.

8X2BXX-

Transmitter Promass 200, 8X2BXX,