Nr
Order number
Specification
34
71108602
I/O module
Non-Ex, Ex.
Current output, 4-20mA HART + 4-20mA
analog.
Usage: FTM50/FTM51/FTM52.
Usage: Promass 200/TB2,
Prosonic Flow 200, Prowirl 200.
34
71164940
I/O module
Non-Ex, Ex.
PROFIBUS PA, FOUNDATION Fieldbus.
PFS=switch output.
Version 2.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57.
Usage: Promass 200, Prowirl 200,
Promag 200.
71128617
Overvoltage protection
4-20mA HART.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57,
FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/
FMR57, FMR60/FMR62/FMR67.
Usage: Promass 200, Prosonic Flow 200,
Promag 200, Prowirl 200.
71128619
Overvoltage protection
4-20mA HART, PROFIBUS PA, FOUNDATION
Fieldbus, Imp./Freq./Switch output.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57,
FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/
FMR57, FMR60/FMR62/FMR67.
Usage: Promass 200, Prosonic Flow 200,
Promag 200, Prowirl 200.
71197334
Transmitter FHX50
Consists of:
electronics, ribbon cable.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57.
Usage: Promass200, Prowirl 200,
Promag 200, Prosonic Flow 200.
Remote display FHX50 please order with
separate order structure.
71296840
Plug M12, VA
To connect FHX50.
Usage:
FMP50/51/52/53/54/55/56/57,
FMR50/51/52/53/54/56/57.
Not for dust Ex.
Usage: Prowirl 200, Promass 200,
Promag 200, Prosonic Flow 200.
30
XPD0001-
Electronic Promass 200 / TB2
Main electronic module
71206552
Cable
Connection cable, shielded.
Usage: FHX50.
71206554
Cable
Connection cable, shielded.
Usage: FHX50.
71206555
Cable
Connection cable, shielded.
Usage: FHX50.
34
XPD0015-
I/O module, 2-wire, 4-20mA, HART, Ex
Non-Ex, Ex.
1x current output HART.
71206556
Cable
Connection cable, shielded.
Usage: FHX50.
37
71110280
Terminal set 2-wire, I/O module
Consists of:
4x terminal 2-pole, green.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57,
FMR60/FMR62/FMR67.
Usage: Promass 200/TB2,
Prosonic Flow 200, Promag 200,
Prowirl 200.
34
XPD0016-
I/O module, 2-wire, 4-20mA,HART, PFS, Ex
Non-Ex, Ex.
1x current output HART.
1x PFS= pulse/freq./switch output.
40
XPD0024-
Display module, SD02, push buttons
For housing: GT18, GT19, GT20.
Usage:
FMP50/51/52/53/54/55/56/57,
FMR50/51/52/53/54/56/57,
FMR60/62/67, FHX50.
Promass 200/TB2, Prosonic Flow 200,
t-mass 150, Promag 200, Prowirl 200.
Consists of:
Display SD02, helix cable,
ribbon cable, connector cover.
40
XPD0025-
Display module, SD03, Touch Control
For housing: GT18, GT19, GT20.
Usage:
FMP50/51/52/53/54/55/56/57,
FMR50/51/52/53/54/56/57,
FMR60/62/67, FHX50.
Promass 200/TB2, Prosonic Flow 200,
Promag 200, Prowirl 200.
Consists of:
Display SD03 illuminated, ribbon cable,
connector cover.
20
71110281
Aluminum cover
Material: 316L.
O-ring, EPDM, PTFE coated.
Usage: FMP51/FMP52/FMP54/FMP55/
FMP56/FMP57, FMR51/FMR52/FMR53/
FMR54/FMR57, FMR62/FMR67.
Usage: Promass 200/TB2,
Prosonic Flow 200, Prowirl 200.
20
71110282
Aluminum cover
Material: 316L.
O-ring NBR, PTFE coated.
Usage: FMP51/FMP52/FMP54/FMP55/
FMP56/FMP57, FMR51/FMR52/FMR53/
FMR54/FMR57, FMR62/FMR67, FHX50.
Usage: Promass 200/TB2,
Prosonic Flow 200, Prowirl 200.
25
71110291
Aluminum cover
Material: 316L.
O-ring EPDM, PTFE coated.
Usage: terminal compartment,
not for Ex d/XP,
FMP51/FMP52/FMP54/FMP55/FMP56/FMP57,
FMR51/FMR52/FMR53/FMR54/FMR57,
FMR62/FMR67.
Usage: Promass 200/TB2,
Prosonic Flow 200, Prowirl 200.
25
71110284
Aluminum cover
Material: 316L.
O-ring EPDM /PTFE coated.
Usage: terminal compartment Ex d/XP,
FMP51/FMP52/FMP54/FMP55/FMP56/FMP57,
FMR51/FMR52/FMR53/FMR54/FMR57,
FMR62/FMR67.
Usage: Promass 200/TB2,
Prosonic Flow 200, Prowirl 200.
25
71185516
Cover
Material: 316L.
O-ring EPDM, PTFE coated.
Usage: terminal compartment,
for overvoltage protection,
not for Ex d/XP,
FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/
FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/
FMP54/FMP56/FMP57, FMR62/FMR67.
Usage: Promass 200, Prosonic Flow 200,
Prowirl 200.
20
71110299
Aluminum cover
Material: aluminium, coated.
O-ring EPDM, PTFE coated.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57,
FMR60/FMR62/FMR67.
Usage: Promass 200/TB2,
Prosonic Flow 200, Promag 200,
Prowirl 200.
20
71110297
Aluminum cover
Material: aluminium, coated.
O-ring EPDM, PTFE coated.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57,
FMR60/FMR62/FMR67.
Usage: Promass 200/TB2,
Prosonic Flow 200, Promag 200,
Prowirl 200.
25
71110301
Aluminum cover
Material: aluminium, coated.
O-ring EPDM, PTFE coated.
Usage: terminal compartment,
not for Ex d/XP,
FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/
FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/
FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.
Usage: Promass 200/TB2,
Prosonic Flow 200, Promag 200,
Prowirl 200.
25
71110302
Aluminum cover
Material: aluminium, coated.
O-ring EPDM, PTFE coated.
Usage: terminal compartment Ex d/XP,
FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/
FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/
FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.
Usage: Promass 200/TB2,
Prosonic Flow 200, Promag 200,
Prowirl 200.
25
71185517
Aluminum cover
Material: aluminium.
O-ring EPDM, PTFE coated.
Usage: terminal compartment,
for overvoltage protection,
not for Ex d/XP,
FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/
FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/
FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.
Usage: Promass 200, Prosonic Flow 200,
Promag 200, Prowirl 200.
15
50103658
Cable gland
15
50098036
Ex cable gland
Kit 10 cable glands M20x1.5 Ex
15
71069285
Cable gland kit
15
50098041
Adapter
Kit 10 extension M20x1.5/G 1/2"
15
71115505
M20x1.5/G 1/2" adapter
15
50098042
Adapter
Kit 10 extension M20x1.5/NPT 1/2"
15
71115509
M20x1,5/NPT1/2" adapter
15
50098037
PA bus cable gland
Kit Cable gland Profibus PA
Kit 10 extension M20x1.5/PG13,5
15
50094984
FF bus cable gland
Kit Cable gland Found. Fieldbus
65
71110303
Housing seal kit
Consists of:
O-ring 88.5x3.53 EPDM/PTFE,
cover electronics compartment,
housing GT19.
O-Ring 88.5x3.53 NBR,
cover electronics compartment,
housing GT18, GT20.
O-ring 91.67x3.53 EPDM/PTFE,
cover terminal compartment,
housing GT19.
O-Ring 91.67x3.53 NBR,
cover terminal compartment,
housing GT18, GT20.
O-ring 50.39x3.53 EPDM/PTFE,
housing/sensor.
FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57,
FMR60/FMR62/FMR67.
Usage: Promass 200/TB2,
Prosonic Flow 200, Promag 200,
Prowirl 200.
19
71115174
Housing filter plug (304)
Consists of:
2x filter plug metall 316L.
1x pressure compensation filter.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57,
FMR62/FMR67.
Usage: Promass 200/TB2,
Prosonic Flow 200, Prowirl 200.
19
71115175
Housing filter plug (brass/nickel)
Consists of:
2x filter plug brass nickel,
pressure compensation filter.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57,
FMR60/FMR62/FMR67.
Usage: Promass 200/TB2,
Prosonic Flow 200, Promag 200,
Prowirl 200.
17
71115176
Housing mounting clamp
Usage: housing GT18/GT19/GT20,
FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/
FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/
FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.
Usage: Promass 200/TB2,
Prosonic Flow 200, Promag 200,
Prowirl 200.
71162242
Cover|GT18/GT19/GT20,316L
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57,
FMR50/FMR51/FMR52/FMR53/FMR54/
FMR56/FMR57, FMR60/FMR62/FMR67.
Usage: Promass 200/TB2,
Prosonic Flow 200, Promag 200, Prowirl
200.
8X2BXX-
Transmitter Promass 200, 8X2BXX,