8H1B Flowmeter Spare Parts Overview
The 8H1B series flowmeter is widely used in industrial process measurement, and its spare parts management is crucial for equipment maintenance. This article compiles a list of commonly used spare parts for this series, including intrinsically safe safety barriers, electronic plug-ins, display modules, covers, sealing rings, and cable glands, for reference by engineering technicians and procurement.
Spare Parts Detail Table
The following table lists the order numbers, specifications, and applicable models of main spare parts for the 8H1B series, facilitating quick inquiry and selection.
| Nr | Order Number | Specification | Applicable Model/Description |
|---|---|---|---|
| 47 | 71185785 | Intrinsically safe safety barrier | Promass 100, CNGmass, LPGmass, LNGmass |
| 45 | 71185787 | Safety barrier connection component | Promass 100, CNGmass, LPGmass, LNGmass; includes 2x Connection terminal 4-Pol. |
| 30 | XPD0005- | Electronic plug-in 100 quality | Main electronic module; suffix codes: H, 85, AA, BM, BS, BU, C2, C4, I5, M5, MM, MN, UR, B, L, M, N, R, AA, JM, 68, 69, 70, 71, 72, 73, 74 |
| 39 | 71185788 | T-DAT module | — |
| 50 | XPD0023- | Display module | Promag 100, Promass 100, Prosonic Flow E 100; suffix codes: B, A, B, C, 0, 21 |
| 21 | 71185789 | Aluminum cover | Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass; includes Cover Aluminium, coated. O-Ring 113,90 x 3,53 NBR for cover. |
| 21 | 71185790 | Stainless steel cover | Promass 100, Promag 100, Prosonic Flow 100; includes Cover stainless 1.4301. Gasket EPDM for cover. |
| 21 | 71185793 | Stainless steel cover | Promag/Promass 100, Promag/Promass 500 digital, sensor connection housing; includes cover stainless 1.4301, gasket EPDM for cover. |
| 20 | 71266334 | Aluminum cover assembly, glass window, integrated | Promass 100, Promag 100, Prosonic Flow E 100/E Heat; includes Cover with sight glass Aluminium, coated. O-Ring 113,90 x 3,53 NBR for cover. |
| 20 | 71266335 | Aluminum cover assembly, glass window, integrated | Promass 100, Promag 100, Prosonic Flow 100; includes Cover with sight glass stainless 1.4301. Gasket EPDM for cover. |
| 20 | 71266337 | Aluminum cover assembly, glass window, ultra-compact | Promass 100, Promag 100; includes Cover with sight glass stainless 1.4301. Gasket EPDM for cover. |
| 70 | 71185795 | Aluminum housing sealing ring | Promass 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass; includes O-Ring 113,90 x 3,53 NBR for cover. Gasket EPDM for housing/sensor. |
| 70 | 71185797 | Stainless steel housing sealing ring | Promass 100, Prosonic Flow 100; includes Gasket EPDM for cover. Gasket EPDM for housing/sensor. |
| 70 | 71185799 | Housing sealing ring | Promass 100, Promass 500 digital, sensor connection housing; includes gasket EPDM for cover, gasket EPDM for housing/sensor. |
| 15 | 50098036 | Explosion-proof cable gland | Kit 10 cable glands M20x1.5 Ex |
| 15 | 71069285 | Cable gland assembly | — |
| 15 | 50098041 | Adapter | Kit 10 extension M20x1.5/G 1/2" |
| 15 | 71185802 | Cable gland assembly | Includes 2 x Extension M20x1,5/G1/2" 1.4404. 2 x O-Ring. 2 x Sealing plug G1/2". |
| 15 | 50098042 | Adapter | Kit 10 extension M20x1.5/NPT 1/2" |
| 15 | 71185800 | Cable gland assembly | Includes 2 x Extension M20x1,5/NPT1/2" 1.4404. 2 x O-Ring. 2 x Sealing plug NPT1/2". |
| 12 | 71276494 | Clamp fastening, screw | Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass, Promag/Promass 500, Promag 10, Promag/Promass/Prosonic Flow/t-mass 500 digital, Promag 400/800(C), (C) = generation index C, sensor connection housing; includes cover clamp, screw M4x16. |
| — | XPRFID- | Spare RFID TAG | Includes RFID TAG, fixing wire, crimp sleeve. Suffix codes: AA, BA, CA, IA, MA, UR, 1 |
Key Spare Parts Selection Points
Safety Barrier and Connection Components
- Intrinsically safe safety barrier (Order No. 71185785) is suitable for Promass 100, CNGmass, LPGmass, LNGmass, ensuring the safety of intrinsically safe explosion-proof systems.
- Safety barrier connection component (Order No. 71185787) includes 2 4-pin connection terminals for reliable connection between the safety barrier and the instrument.
Electronic Plug-ins and Display Modules
- Electronic plug-in (XPD0005-) is the main electronic module, and the suffix code must be selected according to the specific model, such as H, 85, AA, etc., to ensure compatibility.
- Display module (XPD0023-) is suitable for Promag 100, Promass 100, Prosonic Flow E 100, and the suffix codes such as B, A, C, etc., must match.
Covers and Sealing Rings
- Aluminum cover (71185789) and stainless steel cover (71185790, 71185793) are suitable for various models, including sealing rings or gaskets, ensuring the protection level.
- Aluminum cover assembly with glass window (71266334, 71266335, 71266337) facilitates observation of the display, available in integrated and ultra-compact types.
- Housing sealing ring (71185795, 71185797, 71185799) is available in aluminum and stainless steel housings, including O-rings and EPDM gaskets, preventing medium leakage.
Cable Glands and Accessories
- Explosion-proof cable gland (50098036) is M20x1.5 Ex, 10 per set, suitable for hazardous areas.
- Adapter (50098041, 50098042) provides G1/2" and NPT1/2" threads for convenient cable entry.
- Cable gland assembly (71185802, 71185800) includes extension, O-ring, and sealing plug, ensuring sealing reliability.
- Clamp fastening screw (71276494) includes cover clamp and M4x16 screw, suitable for various sensor connection housings.
- RFID TAG (XPRFID-) includes fixing wire and crimp sleeve for asset tracking.
Selection and Ordering Recommendations
When ordering, be sure to check the instrument model and suffix code to ensure spare parts compatibility. It is recommended to refer to the original technical manual or consult the supplier for the latest information.
- Confirm the instrument model: such as Promass 100, Promag 100, etc.
- Check the suffix code: the suffix codes of electronic plug-ins and display modules must match.
- Note material requirements: choose aluminum or stainless steel covers and sealing rings according to the environment.
- Explosion-proof areas: use explosion-proof cable glands and intrinsically safe safety barriers.
Correct selection can reduce downtime and improve maintenance efficiency.