65F Thermal Gas Mass Flowmeter Spare Parts List Overview

The 65F thermal gas mass flowmeter is a key instrument in industrial gas flow measurement, and its spare parts management directly affects equipment availability and maintenance costs. This spare parts list lists commonly used spare parts and their order numbers and specifications, facilitating quick query and ordering by engineering technicians and procurement personnel.

Spare parts cover power boards, signal processing modules, output modules, display modules, wiring modules, and housing accessories, suitable for compact and remote installations, and include explosion-proof and non-explosion-proof versions. Correct selection ensures compatibility with existing instruments.

Main Spare Parts Categories and Specifications

Power Boards and Fuses

Power boards provide stable operating voltage for the instrument, while fuses are used for overcurrent protection. When selecting, pay attention to supply voltage and explosion-proof requirements.

Order Number Specification Remarks
50098557 Power board 220V = 85-260VAC Non-explosion-proof
50098558 Explosion-proof power board 220V = 85-260VAC Explosion-proof
50098565 Power board 24V = 20-55VAC / 16-62VDC Non-explosion-proof
50098566 Explosion-proof power board Kit P.s.b. 40/8X/65 20-55AC 16-62DC Ex Explosion-proof
50094002 Fuse Kit 10 fuses 250 VAC T800 MA Pack of 10
50094003 Fuse Kit Bus/connec.b.5X/40/8X/65 field hous. For field housing

Signal Processing Modules

Signal processing modules are responsible for amplifying and processing sensor signals, divided into compact and remote types, with explosion-proof and non-explosion-proof versions. Preamplifier modules are used for remote non-explosion-proof sensors.

Order Number Specification Remarks
71008429 Compact explosion-proof signal processing module Kit meas.amplifier t-mass 65 compact Ex Explosion-proof
71008430 Remote explosion-proof signal processing module Kit meas.amplifier t-mass 65 remote Ex Explosion-proof
71008448 Preamplifier module Kit preamplifier 65 remote sens non Ex Non-explosion-proof

Output Modules

Output modules provide current, frequency, and relay outputs to meet different control system interface requirements. Note the difference between explosion-proof and intrinsically safe.

Order Number Specification Remarks
50096757 Explosion-proof current/frequency output module Kit com50/40/80/90 curr/Freq.out Ex Explosion-proof
50098300 Explosion-proof current frequency/2-channel relay output module Kit com 53/83/93/65 curr/freq/2Relay Ex Explosion-proof
50098302 Intrinsically safe passive current/frequency output module Kit com5X/40/8X/93/65 Iout pass/Freq.Exi Intrinsically safe
50098303 Intrinsically safe active current/frequency output module Kit com5X/40/8X/93/65 Iout act/Freq.Exi Intrinsically safe
50104625 Intrinsically safe active current output module Kit com 83/65 2x Iout aktiv Exi Intrinsically safe
50104626 Intrinsically safe passive current output module Kit com 83/65 2x Iout passiv Exi Intrinsically safe
71021742 Communication module
71095035 Input/output board C14 EX 53/55/83/93/65 Explosion-proof
71066579 Input/output board PA Ex 50/53/55/80/83/93/65 Explosion-proof
71021743 ModbusRS485+stat.In 2Interf.Ex communication component 53/83/84/65/8CN/8DF Explosion-proof
50096833 Explosion-proof output base module with 3 interfaces Kit Com53/8X/93/65 curr.out 3 Interf.Ex Explosion-proof
50096834 Current output submodule Kit Sub PCB 53/8X/93/65 current out
50096835 Frequency output submodule Kit Sub PCB 53/8X/93/65 frequency out
50096837 Status input submodule Kit Sub PCB 53/8X/93/65 Status input
50098562 53/53/65 current input submodule 53/55/83/65

Display Modules

Display modules are used for on-site reading and operation. Wall-mounted and field-mounted versions are different; note version compatibility.

Order Number Specification Remarks
50108131 Wall-mounted display module for version 1.06.00 and above Kit disp.50/51/80/90/65 Wall >=V1.06.00 Wall-mounted
50108132 Display module for 50/51/80/65 higher than version 1.06.00 Kit display mod 50/51/80/65 >=V1.06.00 Field

Wiring Modules and Terminals

Wiring modules and terminals ensure reliable electrical connections. Explosion-proof cavity terminal covers are used in hazardous areas.

Order Number Specification Remarks
50094014 Wiring module Kit connec. board In/Output Wall encl Wall-mounted
71008431 Wall-mounted terminal Kit connec. board 65 wall encl. non Ex Non-explosion-proof
71008445 Explosion-proof cavity terminal cover Kit Terminal protective Cover Ex Explosion-proof
50094016 Field-mounted terminal board Field
50094017 Wall-mounted board housing Kit Bus PCB/PCB carr.5X/8X/9X/65 wall Wall-mounted
50094004 Transmitter T-DAT data module Kit T-DAT Transmitter Data Chip
71084176 S-Data module with settings Serialnumber is forceful required Serial number required
50108139 5X/8X/40/65 field-mounted terminal block Kit Termin.Block field hous. 5X/8X/40/65 Field
50108140 5X/8X/9X/65 wall-mounted terminal block Kit Termin.Block Wall encl. 5X/8X/9X/65 Wall-mounted

Housing and Accessories

Housing accessories include blind covers, glass covers, terminal compartment covers, O-rings, cable glands, etc., ensuring protection rating and explosion-proof performance.

Order Number Specification Remarks
50094028 5X/40/8X/65 blind cover Kit Cover 5X/40/8X/65 version blind
50094029 Blind cover Kit Cover 5X/40/8X/93/65 vers. blind Exd Explosion-proof
50094026 5X/40/8X/65 glass cover Kit Cover 5X/40/8X/65 with window
50094027 Cover with glass window Kit Cover 5X/40/8X/93/65 with window Exd Explosion-proof
50094038 Terminal compartment cover 10/5X/40/8X/93/65/92F
71247838 **Service cover, remote type Usage: 10/5X/8X/8DF/8CN/92F/65/400/800 acc. service info SI01351D-1/06 Consists of: Cover Rep.kit for G14, O-Ring 110.00 x 4.50 HNBR, Grease Service kit
50094039 Increased safety terminal compartment cover Kit Cover 5X/40/8X/93/65 Conn.termi.Exe Increased safety
50094040 Flameproof terminal compartment cover Kit Cover 5X/40/8X/93/65 Conn.termi.Exd Flameproof
50094041 Wall-mounted sealing cover Kit Seal cover to Wall enclosure Wall-mounted
50094050 Field-mounted sealing ring Kit 10 Seal cover to field housing Pack of 10
50096840 Cable gland Kit 10 cable glands M20x1,5 Pack of 10
50098036 Explosion-proof cable gland Kit 10 cable glands M20x1.5 Ex Pack of 10, explosion-proof
50098041 Adapter Kit 10 extension M20x1.5/G 1/2" Pack of 10
50098042 Adapter Kit 10 extension M20x1.5/NPT 1/2" Pack of 10
50096839 Circuit board bracket (field/stainless steel housing) Kit Circuit board cpl field/SS-housing
50099102 Cast aluminum/stainless steel housing sleeve
50096838 Display screen (field housing) Kit 2 Screening sheet field housing
50096841 Ground terminal/cover clamp Kit Ground terminal / Cover clamp
71009191 65I/F remote housing gasket Kit housing gaskets 65I/F remote non Ex Non-explosion-proof
71009193 Compact component Kit Part 65I/F fieldhous.compact non Ex Non-explosion-proof
71009192 Remote field-mounted component Kit Part 65I/F fieldhous. Remote non Ex Non-explosion-proof

Selection and Ordering Precautions

Correct selection is key to ensuring compatibility of spare parts with the instrument. Please follow these steps:

  1. Confirm the instrument model and serial number, especially the 65F or 65I series.
  2. Determine the installation type: compact or remote, field-mounted or wall-mounted.
  3. Confirm the explosion-proof grade: explosion-proof, intrinsically safe, or non-explosion-proof.
  4. Check the supply voltage and output signal type.
  5. For spare parts requiring a serial number, such as the S-Data module, be sure to provide the instrument serial number.
  6. Refer to relevant service information (e.g., SI01351D-1/06) to ensure correct replacement.

When ordering, please provide the complete order number and specification description to avoid incorrect shipment. If in doubt, it is recommended to contact the manufacturer or authorized distributor.

Frequently Asked Questions (FAQ)

How to determine if a spare part is suitable for my 65F flowmeter?

Please check the instrument model, installation type, explosion-proof grade, and supply voltage. The specification column in the spare parts list indicates the applicable series, such as "65" or "5X/8X/65".

Can explosion-proof spare parts and non-explosion-proof spare parts be interchanged?

No. Explosion-proof spare parts are specially designed, and non-explosion-proof spare parts cannot be used in hazardous areas, otherwise it may cause safety accidents.

What is the significance of display module version V1.06.00?

The version number indicates software compatibility. Display modules with version V1.06.00 or higher are suitable for corresponding versions of transmitters. When purchasing, confirm the existing version.

What items are included in the service cover kit?

The service cover kit (order number 71247838) includes a G14 service cover, O-ring 110.00 x 4.50 HNBR, and grease. For details, please refer to service information SI01351D-1/06.

Summary

The spare parts list for the 65F thermal gas mass flowmeter provided in this article covers the main spare parts and gives key points for selection and ordering. Correct selection of spare parts can ensure long-term stable operation of the flowmeter and reduce maintenance costs. Users are advised to purchase according to actual working conditions and instrument configuration in conjunction with this list.