Nr
Order No.
Specification
F
50098557
Power Board
220V = 85-260VAC
F
71039431
Power Board
HE = harsh environment
220V = 85-260VAC
F
71039431
Power Board
HE = harsh environment
220V = 85-260VAC
F
50098558
Ex Power Board
220V = 85-260VAC
F
71039432
Ex Power Board
HE = harsh environment
220V = 85-260VAC
F
50098565
Power Board
24V = 20-55VAC / 16-62VDC
F
71039434
Power Board
HE = harsh environment
24V = 20-55VAC / 16-62VDC
F
50098566
Ex Power Board
Kit P.s.b. 40/8X/65 20-55AC 16-62DC Ex
F
71039436
Ex Power Board
HE = harsh environment
24V = 20-55VAC / 16-62VDC
7
50094002
Fuse
Kit 10 fuses 250 VAC T800 MA
7
50094003
Fuse
Kit Bus/connec.b.5X/40/8X/65 field hous.
B
50106097
Ex Amplifier Board
Kit meas. amplifier PMASS 83 WEA EX
B
71039409
Ex Amplifier Board
Language: FR, ES, IT, NL, PT, DE, EN
HE = harsh environment
B
50106098
Ex Amplifier Board
Kit meas. amplifier PMASS 83 EES EX
B
71039410
Ex Amplifier Board
Language: SV, FI, NO, RU, PL, CS, EN
HE = harsh environment
B
50106099
Ex Amplifier Board
Kit meas. amplifier PMASS 83 SEA EX
B
71039411
Ex Amplifier Board
Language: JA, ID, EN
HE = harsh environment
B
50108135
Ex Amplifier Board
Kit meas. amplifier Pmass 83 CN EX
B
71039412
Ex Amplifier Board
Language: ZH, EN
HE = harsh environment
B
71261695
Ex Amplifier Board
Language: DE+FR+IT+ES+EN
B
71261696
Ex Amplifier Board
Language: DE+FR+IT+ES+EN
HE = harsh environment
B
71261697
Ex Amplifier Board
Language: RU+NL+PT+CS+EN
B
71261698
Ex Amplifier Board
Language: RU+NL+PT+CS+EN
HE = harsh environment
B
71261699
Ex Amplifier Board
Language: ZH+PL+ID+EN
B
71261700
Ex Amplifier Board
Language: ZH+PL+ID+EN
HE = harsh environment
B
71261701
Amplifier Board
Language: JA+SV+NO+FI+EN
B
71261702
Amplifier Board
Language: JA+SV+NO+FI+EN
HE = harsh environment
C
50098300
Ex Current Frequency/2-Channel Relay Output Module
Kit com 53/83/93/65 curr/freq/2Relay Ex
C
71039475
Input/Output Board
53/55/83
HE = harsh environment
C
50098301
Ex Current/Frequency Output Module
Kit com 53/83/93/65 curr/freq. out Ex
C
71039476
Input/Output Board
53/55/83
HE = harsh environment
C
50098302
Intrinsically Safe Passive Current/Frequency Output Module
Kit com5X/40/8X/93/65 Iout pass/Freq.Exi
C
71039479
Input/Output Board
50/53/8X
HE = harsh environment
C
50098303
Intrinsically Safe Active Current/Frequency Output Module
Kit com5X/40/8X/93/65 Iout act/Freq.Exi
C
71039478
Input/Output Board
50/53/8X
HE = harsh environment
C
71066579
Input/Output Board PA Ex
50/53/55/80/83/93/65
C
71066580
Input/Output Board
HE = harsh environment
C
50101264
Ex Input/Output Board C02
Kit com Pline 53/83/93Found.Fieldbus Ex
C
71095035
Input/Output Board C14 EX
53/55/83/93/65
C
50101264
Ex Input/Output Board C02
Kit com Pline 53/83/93Found.Fieldbus Ex
C
71095035
Input/Output Board C14 EX
53/55/83/93/65
C
71039483
Ex Input/Output Board HE C02
53/55/83
HE = Harsh Environment
C
71095037
Ex Input/Output Board HE C14
53/55/83
HE = Harsh Environment
C
50104625
Intrinsically Safe Active Current Output Module
Kit com 83/65 2x Iout aktiv Exi
C
71039480
Input/Output Board
HE = harsh environment
C
50104626
Intrinsically Safe Passive Current Output Module
Kit com 83/65 2x Iout passiv Exi
C
71039481
Input/Output Board
HE = harsh environment
C
71021742
Communication Module
C
71039484
Input/Output Board
HE = harsh environment
D
71021743
ModbusRS485+stat.In 2Interf.Ex Communication Component
53/83/84/65/8CN/8DF
D
71039485
Input/Output Board
53/83/84/8CN/8DF
HE = Harsh environment
D
50108002
Communication Module
53/55/83/93
D
71039486
Input/Output Board
53/55/83
HE = harsh environment
D
50096833
Ex Output Mother Module with 3 Interfaces
Kit Com53/8X/93/65 curr.out 3 Interf.Ex
D
71039477
Input/Output Board
53/55/8X
HE = harsh environment
D
71105712
Ethernet Input/Output Module
Including Subprint Ethernet
2
50096834
Current Output Submodule
Kit Sub PCB 53/8X/93/65 current out
2
50096834
Current Output Submodule
Kit Sub PCB 53/8X/93/65 current out
2
71039487
Sub Output Board Current Output
53/55/8X
HE = harsh environment
2
71039487
Sub Output Board Current Output
53/55/8X
HE = harsh environment
3
50096835
Frequency Output Submodule
Kit Sub PCB 53/8X/93/65 frequency out
3
50096835
Frequency Output Submodule
Kit Sub PCB 53/8X/93/65 frequency out
3
71039489
Sub Output Board Frequency Output
53/55/80/83
HE = harsh environment
3
71039489
Sub Output Board Frequency Output
53/55/80/83
HE = harsh environment
4
50096837
Status Input Submodule
Kit Sub PCB 53/8X/93/65 Status input
4
71039492
Sub Output Board Status Output
53/55/8X
HE = harsh environment
5
50096836
Relay Output Submodule
Kit Sub PCB Pline53/83/93 Relay out
5
50096836
Relay Output Submodule
Kit Sub PCB Pline53/83/93 Relay out
5
71039491
Sub Output Board Relay Output
53/55/83/84/8CN/8DF
HE = Harsh environment
5
71039491
Sub Output Board Relay Output
53/55/83/84/8CN/8DF
HE = Harsh environment
6
50098562
53/53/65 Current Input Submodule
53/55/83/65
6
71039488
Sub Output Board Current Input
53/55/83
HE = harsh environment
37
71105711
Ethernet Output Sub-board
E
50096754
Display Module
Kit display mod Pline 53/83/84/93
J
50096755
Wall-Mounted Display Module
Kit display mod 53/83/84/93 Wall encl
G
50094016
Field-Mounted Terminal Board
G
71105709
53/83 Ethernet Bus Interface Board
21
50094017
Wall-Mounted Board Housing
Kit Bus PCB/PCB carr.5X/8X/9X/65 wall
H
50099099
5X/8X Stainless Steel Housing Bus Terminal Module
19
50098637
Wall-Mounted Terminal Board
19
71039493
Wall-Mounted Terminal Board HE
HE = harsh environment
18
50094014
Terminal Module
Kit connec. board In/Output Wall encl
A
50098705
Terminal Board
Sensor: A/I/M/F/H/E/S/P/O/X
A
71039494
Sensor Section Terminal Board
Sensor: A/I/M/F/H/E/S/P/O/X
HE = harsh environment
A
50098706
Ex Terminal Board
Sensor: A/I/M/F/H/E/S/P/O/X
A
71039495
Sensor Section Terminal Board
Sensor: A/I/M/F/H/E/S/O/X,
HE = harsh environment
29
50108139
5X/8X/40/65 Field-Mounted Terminal Block
Kit Termin.Block field hous. 5X/8X/40/65
30
50108140
5X/8X/9X/65 Wall-Mounted Terminal Block
Kit Termin.Block Wall encl. 5X/8X/9X/65
1
50094004
Transmitter T-DAT Data Module
Kit T-DAT Transmitter Data Chip
S
71003952
S-Data Module with Settings
Serialnumber is forceful required
17
50099100
5X/8X Stainless Steel Housing Glass Cover
8
50094026
5X/40/8X/65 Glass Cover
Kit Cover 5X/40/8X/65 with window
32
50094027
Cover with Glass Window
Kit Cover 5X/40/8X/93/65 with window Exd
9
50094028
5X/40/8X/65 Blind Cover
Kit Cover 5X/40/8X/65 version blind
33
50094029
Blind Cover
Kit Cover 5X/40/8X/93/65 vers. blind Exd
10
50094038
Terminal Compartment Cover
10/5X/40/8X/93/65/92F
10
50094038
Terminal Compartment Cover
10/5X/40/8X/93/65/92F
34
50094039
Increased Safety Terminal Compartment Cover
Kit Cover 5X/40/8X/93/65 Conn.termi.Exe
35
50094040
Flameproof Terminal Compartment Cover
Kit Cover 5X/40/8X/93/65 Conn.termi.Exd
15
50096840
Cable Gland
Kit 10 cable glands M20x1,5
15
50098036
Ex Cable Gland
Kit 10 cable glands M20x1.5 Ex
15
50098036
Ex Cable Gland
Kit 10 cable glands M20x1.5 Ex
15
50098036
Ex Cable Gland
Kit 10 cable glands M20x1.5 Ex
15
50098040
Adapter
15
50098041
Adapter
Kit 10 extension M20x1.5/G 1/2"
15
50098041
Adapter
Kit 10 extension M20x1.5/G 1/2"
15
50098042
Adapter
Kit 10 extension M20x1.5/NPT 1/2"
15
50098042
Adapter
Kit 10 extension M20x1.5/NPT 1/2"
15
50098037
PA Bus Cable Gland
Kit Cable gland Profibus PA
Kit 10 extension M20x1.5/PG13,5
15
50094984
FF Bus Cable Gland
Kit Cable gland Found. Fieldbus
15
71105713
53/83 Ethernet Bus Interface
15
71105713
53/83 Ethernet Bus Interface
12
50096839
Circuit Board Bracket (Field/Stainless Steel Housing)
Kit Circuit board cpl field/SS-housing
14
50099102
Cast Aluminum/Stainless Steel Housing Bushing
36
71008445
Ex Compartment Terminal Cover
Kit Terminal protective Cover Ex
13
50096841
Ground Terminal/Cover Clamp
Kit Ground terminal / Cover clamp
50096838
Display (Field Housing)
Kit 2 Screening sheet field housing
50098636
Display (Wall-Mounted)
16
50099101
Stainless Steel Housing Seal Ring
20
50094041
Wall-Mounted Seal Cover
Kit Seal cover to Wall enclosure
11
50094050
Field-Mounted Seal Ring
Kit 10 Seal cover to field housing
23
50098701
Stainless Steel Housing One-Piece Fitting
Sensor: A/I/M/F/H/S/P
22
50098702
Field Housing One-Piece Fitting
Sensor: A/I/M/F/H/S/P/O
24
50098704
Sensor Housing Seal Ring
Sensor: A/I/M/F/H/E/S/P/C/O/X
28
50093554
10m Cable
Kit cable Promass remote version 10m
28
50093573
20m Cable
Kit cable Promass remote version 20m
28
50098567
Separate Type 10m Ex Cable
28
50098568
Separate Type 20m Ex Cable
83XXX-
**Promass 83 Transmitter 83XXX
Mass Flowmeter
Sensor:
XXX
83F/83M/83A/83I/83S/83P/83H/83E/83X
Version:
XXX
Transmitter only
Approval:
9
Special version, TSP-no. to be spec.
A
Non-hazardous area
B
ATEX II 2GD+ IECEx Z1,21 Ex dia IIC Ex tD A21 Z= Zone
D
ATEX II 2GD+ IECEx Z1,21 Ex deia IIC Ex tD A21 Z= Zone
H
ATEX II 3G EEx n IIC
N
XP FM Cl.I Div.1/CSA Cl.I Div.1, ABCD + Zone 1
R
FM NI Cl.I Div.2/CSA Cl.I Div.2, ABCD + Zone 2
Housing:
1
Compact IP67 NEMA4X, Alu, -40oC/oF T-amb.
2
Compact IP67 NEMA4X, stainless, -40oC/oF T-amb.
3
Remote, wall IP67 NEMA4X,-40oC/oF T-amb. without cable
4
Compact IP67 NEMA 4X, Alu, HE, -40oC/oF T-amb., HE = harsh environment
5
Compact IP67 NEMA4X, stainless, HE -40oC/oF T-amb., HE = harsh environment
6
Remote, wall IP67 NEMA4X, HE, -40oC/oF T-amb. without cable, HE = harsh environment
7
Remote,field IP67 NEMA4X,-40oC/oF T-amb. w/o cable
8
Remote, field IP67 NEMA4X, HE, -40oC/oF T-amb. without cable, HE = harsh environment
9
Special version, TSP-no. to be spec.
A
Compact IP67 NEMA4X, Aluminium
B
Compact IP67 NEMA4X, stainless
C
Remote, wall IP67 NEMA4X, w/o cable
E
Remote IP67, Alu, w/o cable
Cable Entry:
9
Special version, TSP-no. to be spec.
A
Gland M20 (EEx d > thread M20)
B
Thread NPT 1/2
C
Thread G 1/2
K
Bus plug + gland M20
L
Bus plug + thread NPT 1/2
M
Bus plug + thread G 1/2
Q
2 x Bus plug + gland M20
R
2 x Bus plug + thread NPT 1/2
S
2 x Bus plug + thread G 1/2
Power Supply; Display:
4
HART 7; 85-260VAC; Language ZH+PL+ID+EN; 4-line + Touch control
5
HART 7; 20-55VAC /16-62VDC; Language ZH+ PL+ID+EN; 4-line +Touch control
7
85-260VAC; WEA, w/o display, Remote configuration, WEA= language DE+EN+FR+IT+ES+PT+NL
8
20-55VAC / 16-62VDC; WEA, w/o display, Remote configuration, WEA= language DE+EN+FR+IT+ES+PT+NL
9
Special version, TSP-no. to be spec.
A
85-260VAC; WEA, 4-line + Touch control WEA= language DE+EN+FR+IT+ES+PT+NL
B
20-55VAC / 16-62VDC; WEA, 4-line + Touch control, WEA= language DE+EN+FR+IT+ES+PT+NL
C
85-260VAC; SEA, 4-line + Touch control SEA= language JA+ID+EN
D
20-55VAC / 16-62VDC; SEA, 4-line + Touch control, SEA= language JA+ID+EN
E
85-260VAC; EES, 4-line + Touch control EES= language SV+FI+NO+RU+PL+CS+EN
F
20-55VAC / 16-62VDC; EES, 4-line + Touch control, EES= language SV+FI+NO+RU+PL+CS+EN
G
85-260VAC; CN, 4-line + Touch control, CN= language ZH + EN
H
20-55VAC / 16-62VDC; CN, 4-line + Touch control, CN= language ZH + EN
P
HART 7; 85-260VAC; Language DE+FR+IT+ES+ EN; 4-line + Touch control
Q
HART 7; 20-55VAC /16-62VDC; Language DE+ FR+IT+ES+EN; 4-line +Touch control
R
HART 7; 85-260VAC; Language RU+NL+PT+CS+ EN; 4-line + Touch control
S
HART 7; 20-55VAC /16-62VDC; Language RU+ NL+PT+CS+EN; 4-line +Touch control
T
HART 7; 85-260VAC;Language JA+SV+NO+FI+ EN; 4-line + Touch control
U
HART 7; 20-55VAC /16-62VDC; Language JA+ SV+NO+FI+EN; 4-line +Touch control
Adjustment; Software Feature
9
Special version, TSP-no. to be spec.
A
Default liquid; Basic version
B
Default gas; Basic version
C
Default liquid; Concentration measurement
D
Default gas; Advanced diagnostics
E
Default liquid; Advanced diagnostics
J
Default liquid; Batching
K
Default gas; Batching
L
Default liquid; Batching + Concentration measurement
N
Default liquid; Batching + Advanced diagnostics
R
Default liquid; Advanced diagnostics + Concentration measurement
T
Default liquid; Batching + Diagnostics+ Concentration measurement
Output; Input:
0
4-20mA SIL HART + 2x 20mA + stat.In modules exchangeable
2
4-20mA SIL HART + freq.+relay+20mA out modules exchangeable
3
4-20mA SIL HART + relay + 20mA, (1x out, 1x in), modules exchangeable
4
4-20mA SIL HART + freq.+relay+20mA in, modules exchangeable
5
4-20mA SIL HART + freq.+20mA in+stat.In modules exchangeable
6
4-20mA SIL HART + stat.In + 20mA, (1x out, 1x in), modules exchangeable
7
Modbus RS485 + 2x relay + stat.In, modules exchangeable
9
Special version, TSP-no. to be spec.
A
4-20mA SIL HART + frequency
B
4-20mA SIL HART + freq. + 2x relay
C
4-20mA SIL HART + freq. + 2x relay M= modules exchangeable
D
4-20mA SIL HART + freq.+ relay+stat.In modules exchangeable
E
4-20mA SIL HART + 20mA+ relay+stat.In modules exchangeable
F
PROFIBUS PA, Ex-i
G
FOUNDATION Fieldbus, Ex-i
H
PROFIBUS PA
I
EtherNet/IP
J
PROFIBUS DP
K
FOUNDATION Fieldbus
L
4-20mA SIL HART + 2x relay + stat.In modules exchangeable
M
4-20mA SIL HART + 2x freq. + stat.In modules exchangeable
N
Modbus RS485 + 20mA +freq.+stat.In modules exchangeable
P
PROFIBUS DP + 20mA + freq.+ stat.In modules exchangeable
Q
Modbus RS485 + stat.In
R
4-20mA SIL HART + 0/4-20mA, active Ex-i
S
4-20mA SIL HART active + freq., Ex-i, freq. = passive
T
4-20mA SIL HART passive + freq., Ex-i, freq. = passive
U
4-20mA SIL HART + 0/4-20mA, passive Ex-i
V
PROFIBUS DP + 2x relay + stat.In modules exchangeable
W
4-20mA SIL HART + 2x 20mA + relay, modules exchangeable
>>Marking:
Z1
Tagging (TAG), see additional spec.
Z2
Bus address, see additional spec.