CPS16D Spare Parts List Overview
The CPS16D spare parts list lists commonly used maintenance accessories and consumables for pH measurement systems. These accessories are essential for ensuring electrode performance, extending service life, and ensuring measurement accuracy. Based on the original spare parts list, this article organizes the order numbers, specifications, and uses of key accessories for easy reference by engineering technicians and procurement personnel.
Detailed Explanation of Main Spare Parts
Electrode Protective Caps
- Order Number: 71538217
- Specifications: CPSxx electrode protective caps, 20 pc protective caps for pH sensors
- Usage: Used to protect pH sensor electrodes from damage or contamination.
ORP Calibration Solution
- Order Number: CPY3-
- Specifications: ORP calibration solution CPY3
- Usage: Used for calibration of ORP electrodes to ensure measurement accuracy.
KCl Electrolyte
- Order Number: CPY4-
- Specifications: KCl electrolyte CPY4, For liquid filled electrodes
- Usage: Used for electrolyte replenishment of liquid-junction electrodes to maintain electrode performance.
Sensor Labels
- Order Number: 71038228
- Specifications: 100 sensor clips with printable labels
- Usage: Used for corresponding identification of sensors and measurement loops for easy management.
pH Standard Solutions
- Order Number: CPY20-
- Specifications: pH quality buffer solution, referenced to primary reference material of PTB and standard reference material of NIST. With calibration certificate buffer solution
- Usage: Used for calibration of pH electrodes, providing traceable standard buffer solutions.
Selection and Ordering Guide
Select appropriate spare parts according to measurement requirements to ensure compatibility with existing systems. The following table summarizes key information for quick reference.
| Spare Part Name | Order Number | Specification Description | Usage |
|---|---|---|---|
| Electrode Protective Caps | 71538217 | CPSxx electrode protective caps, 20 pc | Protect pH sensor electrodes |
| ORP Calibration Solution | CPY3- | ORP calibration solution CPY3 | ORP electrode calibration |
| KCl Electrolyte | CPY4- | KCl electrolyte CPY4 | Electrolyte replenishment for liquid-junction electrodes |
| Sensor Labels | 71038228 | 100 sensor clips with printable labels | Sensor identification and loop correspondence |
| pH Standard Solutions | CPY20- | pH quality buffer solution | pH electrode calibration |
Maintenance and Usage Recommendations
- Regularly check whether the electrode protective caps are intact and replace damaged protective caps in time.
- According to usage frequency, regularly calibrate electrodes with ORP calibration solution and pH standard solutions.
- For liquid-junction electrodes, regularly replenish KCl electrolyte to prevent the electrolyte from drying out.
- Use sensor labels to clearly identify the measurement loop corresponding to each sensor to avoid confusion.
Following the above recommendations can effectively improve the reliability and service life of the measurement system.