CLS19 Conductivity Sensor Spare Parts Overview

The CLS19 conductivity sensor is widely used in industrial process measurement. To ensure its long-term stable operation, regular replacement of spare parts is essential. This article lists commonly used spare parts, including cable connectors, calibration solutions, and flow cells, to help you quickly select the right one.

CLS19 spare parts diagram

Spare Parts List and Specifications

The table below summarizes the key spare parts for the CLS19 sensor, including order numbers, specifications, and descriptions.

Order Number Specification Description
50015632 Cable connector Old material number: 117234
50081902 Calibration solution 74.0 µS/cm 500 mL, reference temperature 25°C, NIST standard solution, with temperature table, complies with ISO standards
50081903 Calibration solution 500 mL, reference temperature 25°C, NIST standard solution, with temperature table, complies with ISO standards
50081904 Calibration solution 1.406 mS/cm 500 mL, reference temperature 25°C, NIST standard solution, with temperature table, complies with ISO standards
50081905 Calibration solution 500 mL, reference temperature 25°C, NIST standard solution, with temperature table, complies with ISO standards
50081906 Calibration solution 500 mL, reference temperature 25°C, NIST standard solution, with temperature table, complies with ISO standards
CYA21- Flowfit CYA21 Stainless steel flow cell for analytical panel installation, suitable for power plants and chemical industry, maximum 100°C, 16 bar, includes installation kit

Calibration Solution Selection Guide

Calibration solutions are key to ensuring conductivity measurement accuracy. The following are selection points:

  • Range coverage: Provides multiple concentrations such as 74.0 µS/cm and 1.406 mS/cm to meet different measurement ranges.
  • Standard traceability: All calibration solutions are traceable to NIST standard reference materials to ensure calibration reliability.
  • Temperature compensation: Includes a temperature comparison table to support compliant calibration under ISO standards.
  • Packaging specifications: 500 mL bottles for easy on-site use and storage.
Calibration solution product image

Flowfit CYA21 Flow Cell Features

The Flowfit CYA21 is a stainless steel flow cell designed specifically for analytical panels and suitable for high-temperature and high-pressure environments.

Application Areas

  • Power plant water-steam cycle systems
  • Petrochemical process analysis
  • Bypass installation and online monitoring

Technical Advantages

  • Rugged and durable: Stainless steel construction, corrosion-resistant, suitable for harsh working conditions.
  • High temperature and high pressure: Maximum operating temperature 100°C, pressure 16 bar.
  • Easy installation: Includes installation kit, can be quickly integrated into analytical panels.
  • Bypass suitable: Perfectly suited for bypass installation, convenient for maintenance.
Flowfit CYA21 flow cell

Maintenance and Procurement Recommendations

To ensure long-term stable operation of the CLS19 sensor, it is recommended to regularly inspect and replace spare parts.

  1. Select the appropriate calibration solution according to the measurement range and calibrate regularly.
  2. Check the connection status of the cable connector to avoid signal interference.
  3. The flow cell should be cleaned regularly according to working conditions to prevent blockage.
  4. When purchasing, please verify the order number to ensure compatibility with existing equipment.

For more technical information, please refer to the product manual or contact the supplier.