CLS50 Spare Parts List Overview

This article provides a spare parts list and calibration solution selection guide for the Endress+Hauser CLS50 conductivity sensor, suitable for engineering maintenance and procurement. All spare parts are listed with order numbers and specifications for quick lookup.

CLS50 Spare Parts List

CLS50 Seals and O-rings

Seals are key to ensuring long-term stable operation of the sensor, and different materials are suitable for different media.

  • 71086368: CLS50 CHEMRAZ O-ring, chemical corrosion resistant.
  • 71086369: Kit CLS50 >20081001: VITON O-ring, suitable for general industrial applications.
  • 71086372: PTFE seal ring CLS50 DN50, high temperature and strong corrosion resistant.
  • 71086374: Kit CLS50 ANSI+JIS >20081001: PTFE gasket, compatible with multiple flange standards.
CLS50 Seals

CLS50 Flanges and Accessories

Flanges and cable accessories ensure stable sensor installation and reliable signal transmission.

Order Number Specification
51500525CLS50 DN50 SS flange
51500527Flange
51500934Flange
51500935Flange
51500936Flange
51500937Flange
51500753Cable accessory CLS50/52
CLS50 Flanges

Conductivity Calibration Solution Selection

Calibration solutions are used for precise calibration of conductivity measurement systems, compliant with ISO standards and referencing NIST SRM.

Calibration Solution Specifications and Order Numbers

Order Number Conductivity Value Description
5008190274.0 µS/cm500 ml, reference temperature 25°C, NIST SRM, with temperature table
50081903Not specified500 ml, reference temperature 25°C, NIST SRM, with temperature table
500819041.406 mS/cm500 ml, reference temperature 25°C, NIST SRM, with temperature table
50081905Not specified500 ml, reference temperature 25°C, NIST SRM, with temperature table
50081906Not specified500 ml, reference temperature 25°C, NIST SRM, with temperature table

Note: Some calibration solutions do not specify the exact conductivity value; please confirm the required range when selecting.

Conductivity Calibration Solutions

Selection and Ordering Recommendations

Select the appropriate seal material and flange standard according to actual working conditions, and regularly calibrate the sensor with calibration solutions.

  1. Confirm the sensor model and production date (e.g., >20081001).
  2. Select the O-ring material (CHEMRAZ, VITON, or PTFE) based on medium corrosiveness.
  3. Verify the flange standard (DN50, ANSI, JIS).
  4. Select the calibration solution conductivity value according to the measurement range.

For a complete spare parts list or technical consultation, please contact us.