COS61D Dissolved Oxygen Sensor Spare Parts Overview

COS61D is a commonly used model for industrial online dissolved oxygen measurement, and its spare parts and maintenance kits are crucial for ensuring long-term stable operation. Based on the original manufacturer's spare parts list, this article systematically organizes order numbers, specifications, and applicable scenarios for quick reference by engineering technicians and procurement personnel.

COS61D Dissolved Oxygen Sensor

Core Spare Parts and Maintenance Kits

Sensor Membrane Caps and Maintenance Kits

  • 51518598: Sensor membrane cap, suitable for COS61/COS61D, single-piece packaging.
  • COV61-: COV61 maintenance kit, including membrane cap, O-rings, and other maintenance materials, for the COS61/COS61x series.

Protective Caps and Calibration Caps

  • 71495128: Kit COSxx standard protective cap.
  • 71495130: COSxx dissolved oxygen sensor protective cap, suitable for fish farm aquaculture applications.
  • 71495126: COSxx 8.5 mm aperture cage-type dissolved oxygen sensor protective cap.
  • 51518599: COS31/41/51D/61/71 calibration cap.

Cleaning and Maintenance Accessories

  • 71110801: Cleaning head, suitable for COS61/61D, 6/8mm.
  • 71110802: Cleaning head, suitable for COS61/61D, 1/4".
  • 71072583: Cleaning unit, 230V air compressor.
  • 71194623: Output air purification device.

Junction Box and Zero-Point Gel

  • 51500832: Junction box RM, used to extend Memosens/CUS31/41 cables, protection rating IP65, with 2x Pg 13.5.
  • COY8-: Zero-point gel COY8, used for zero-point verification, calibration, and adjustment of oxygen and disinfection sensors, suitable for amperometric and optical sensors, diameters 12, 25, 40mm, can be used in the laboratory or on site.

Spare Parts Selection Reference Table

Order NumberSpecification DescriptionApplicable Model/Remarks
51518598Sensor membrane cap, 1 pieceCOS61, COS61D
COV61-Maintenance kit, including membrane cap, O-rings, etc.COS61/COS61x
71495128Standard protective capCOSxx
71495130Protective cap, fish farm aquaculture applicationCOSxx
71495126Cage-type protective cap, 8.5 mm apertureCOSxx
51518599Calibration capCOS31/41/51D/61/71
71110801Cleaning head, 6/8mmCOS61/61D
71110802Cleaning head, 1/4"COS61/61D
71072583Cleaning unit, 230V air compressor-
71194623Output air purification-
51500832Junction box RM, IP65, 2x Pg 13.5Memosens/CUS31/41
COY8-Zero-point gel, diameter 12/25/40mmOxygen and disinfection sensors

Maintenance and Procurement Recommendations

Regular Maintenance Steps

  1. According to the measurement environment, regularly check whether the membrane cap is contaminated or damaged, and replace 51518598 or the COV61- kit if necessary.
  2. When cleaning the sensor, choose an appropriate cleaning head (71110801 or 71110802) to avoid scratching the membrane surface.
  3. During calibration, use the 51518599 calibration cap to ensure a stable calibration environment.
  4. During zero-point verification, use COY8- zero-point gel and operate according to the instructions.

Procurement Notes

  • Confirm the compatibility between the sensor model and spare parts, e.g., COS61D and COS61 spare parts are interchangeable.
  • Select the protective cap according to the application scenario, e.g., choose 71495130 for fish farm aquaculture.
  • When cable extension is required, choose the 51500832 junction box and pay attention to the protection rating.

Correct selection of spare parts can extend sensor life and reduce downtime. It is recommended to confirm the latest order numbers and inventory with the supplier.