FTM52 and Liquiphant M/Soliphant M Spare Parts Overview

This spare parts list applies to FTM52, Liquiphant M, Soliphant M and other series of level instruments. The content covers seals, covers, electronic inserts, cables, and installation accessories, helping engineering technicians and procurement quickly match the required spare parts.

The following sections are organized by spare part category. All order numbers and specifications retain the original data. Please select according to the device model and certification requirements.

Seals and O-rings

Seals are used for sealing between the sensor and housing, and between the cover and housing. Materials include EPDM, VMQ/PTFE, etc. When selecting, pay attention to the housing model and certification requirements.

O-rings and Seal Kits

  • 52004276: O-ring, Gasket sensor/housing F13, suitable for Liquiphant M, Soliphant M
  • 52004137: O-ring, Cover seal set Polyester housing F16
  • 52004277: Seal kit, including 10x O-ring 70.0x3.0 EPDM
  • 52008495: Seal kit, for cover
  • 52028179: Gasket, Profile gasket for cover, stainless steel housing F15

Covers and Sight Glasses

Covers include aluminum covers, stainless steel covers, transparent covers, and sight glass covers, suitable for different housing models and explosion-proof areas. Gasket materials include EPDM, VMQ/PTFE, etc.

Aluminum Covers

  • 52002698: Aluminum cover, O-ring EPDM, for Aluminium housing F13, Ex d
  • 52002699: Aluminum cover, O-ring EPDM, for Aluminium housing F17
  • 52006903: Aluminum cover, O-ring EPDM, for Aluminium housing, suitable for Liquiphant M/S, Liquicap M, Soliphant M
  • 52027693: Aluminum cover, O-ring 70.0x3.0 EPDM, for Aluminium housing F13/F17/F18, not suitable for EEx d
  • 52028271: Aluminum cover, Sight glass: mineral glass, individually tested, EEx d/XP, O-ring EPDM FDA 72.0x3.0, Aluminium housing T13
  • 52007103: Aluminum cover, O-ring EPDM, for terminal compartment, Aluminium housing T13

Stainless Steel Covers and Transparent Covers

  • 52027000: Stainless steel cover, Gasket 67.5x2.9x1.5 VMQ/PTFE, Stainless steel housing F15
  • 52027002: Sight glass cover with gasket, Sight glass: glass, Gasket 67.5x2.9x1.5 VMQ/PTFE, Stainless steel housing F15
  • 52027708: Stainless steel cover, Claw for cover, Gasket 67.5x2.9x1.5 VMQ/PTFE, Stainless steel housing F15, certification 2,3,4,8,D,E, suitable for Soliphant M; certification C,D,E,F,H,J,L,M, suitable for Liquicap M FMI51/FMI52
  • 52027709: Stainless steel cover, Claw for cover, Gasket 67.5x2.9x1.5 VMQ/PTFE, Stainless steel housing F15, certification 2,3,4,8,D,E, suitable for Soliphant M
  • 52025790: Transparent cover, Gasket EPDM, Polyester housing
  • 71185025: Cover, Material: 316L, O-ring 70.0x3.0 FVQM, for stainless steel housing F27, FTL80/FTL81/FTL85, FTM50/FTM51/FTM52

Adapters and Cable Entries

Adapters are used for mechanical connection between the housing and sensor. Cable entry components ensure cable sealing and fixation. Selection must match the housing model and thread specifications.

Adapters

  • 52028204: Adapter, Fixing set, including securing ring 301, adapter disc Alu, screw M3x12, disc 301, suitable for Soliphant M
  • 52004133: Adapter, for Polyester housing F16
  • 52004134: Adapter, for Polyester housing F16
  • 52004135: Adapter, for Polyester housing F16

Cable Entries and Cable Glands

  • 52028180: Cable entry, including adapter M20 > G1/2, 304, gasket EPDM, blind plug G1/2, stainless steel housing F15, suitable for Soliphant M
  • 52028181: Cable entry, including adapter M20 > NPT1/2, 304, gasket EPDM, blind plug NPT1/2, stainless steel housing F15, suitable for Soliphant M
  • 52028182: Cable gland, including cable gland M20, PA, gasket EPDM, stainless steel housing F15, suitable for Soliphant M
  • 52028183: Cable gland, including cable gland M20, metal, for certification 3,4, stainless steel housing F15, suitable for Soliphant M
  • 71435139: M12 plug, 316L, housing side, for M12 screw-in thread, suitable for FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL51B, FTL62, FTL63, FTL64, FTM50, FTM51, FTM52, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B

Electronic Inserts

Electronic inserts provide different power supply methods and output signals, suitable for Soliphant M. Selection depends on supply voltage, output type, and explosion-proof requirements.

Order NumberSpecificationApplicable Model
520264972-wire 19-253VAC, probe circuit, intrinsically safeSoliphant M
520264983-wire PNP 10-55VDC, probe circuit, intrinsically safeSoliphant M
52026499relay DPDT, 19-253VAC/55VDC, probe circuit, intrinsically safeSoliphant M
5202650011-36VDCSoliphant M
520265012-wire PFMSoliphant M
52026502push button (H-L signal)Soliphant M

Cables and Installation Accessories

Cables are used for connection between the sensor and separate housing, length 6m, optional armored type. Installation accessories include mounting sets, removal tools, diagnostic inserts, etc.

Cables

  • 71035208: Cable, Connection sensor > separate housing, length 6m, including housing adapter, cable gland, suitable for separate housing F15/16/17, FTM50/FTM51/FTM52
  • 71035209: Armored cable, Connection sensor > separate housing, length 6m, including protective hose, housing adapter, cable gland, suitable for separate housing F15/16/17, FTM50/FTM51/FTM52
  • 71035210: Cable, Connection sensor > separate housing, length 6m, including housing adapter, cable gland, suitable for separate housing F13/T13, FTM50/FTM51/FTM52
  • 71035211: Armored cable, Connection sensor > separate housing, length 6m, including protective hose, housing adapter, cable gland, suitable for separate housing F13/T13, FTM50/FTM51/FTM52
  • 71035212: Cable, Connection sensor > separate housing, length 6m, including housing adapter, cable gland, suitable for separate housing F13/T13, FTM50/FTM51/FTM52
  • 71035213: Armored cable, Connection sensor > separate housing, length 6m, including protective hose, housing adapter, cable gland, suitable for separate housing F13/T13, FTM50/FTM51/FTM52

Installation and Maintenance Accessories

  • 919806-1000: Mounting set (2"/pipe 38_V4A), suitable for FMI51/FMI52, FTG20, FTI51/FTI52, FTI55/FTI56, FTI77, FTM50/FTM51/FTM52
  • 71026213: Removal tool, suitable for FTM50/FTM51/FTM52, separate housing
  • 71036514: Diagnostic insert, suitable for FTL50/FTL50H/FTL51/FTL51H/FTL51C, FTL70/FTL71, FTL80/FTL81/FTL85, FTM50/FTM51/FTM52
  • 52024632: Cable shortening tool, Rope shortening kit FTM52
  • 71040497: Sunshade cover, suitable for FMI51/FMI52, FTI51/FTI52/FTI55/FTI56, FTI77, FTL50/FTL50H/FTL51/FTL51C/FTL51H, FTL70/FTL71, FTL80/FTL81/FTL85, FTM20/FTM21, FTM50/FTM51/FTM52
  • 71127760: Sunshade cover, suitable for FDR56, FMI21, FMI51/FMI52, FQR56, FTI51/FTI52/FTI55/FTI56, FTI77, FTL50/FTL50H/FTL51/FTL51C/FTL51H, FTL70/FTL71, FTL80/FTL81/FTL85, FTM20/FTM21, FTM50/FTM51/FTM52, FTR20, FTW31/FTW32/FTW33

FTM52 Sensor and Selection Codes

FTM52X- indicates an FTM52 sensor with process connection, optional extension cable, material 316L. Selection codes include 1,2,3,4,6,7,8,A,C,D,E,F,G,H,T,X,Y,Z,AF,AG,AH,AR,B3,BS,BT,GG,GJ,GK,GX,KF,KG,KH,TD,YY, etc. For specific meanings, please refer to the product catalog.

Selection code example: 2,9,B,C,F,G,Y,A,D,E,G,H,Y,1,3,5,7,Y,1,A,Y,A,Y, etc., used for custom sensor configuration.

Notes on Spare Parts Selection

  • Confirm the device model and housing code (e.g., F13, F15, F16, F17, T13, etc.).
  • Pay attention to explosion-proof certification requirements (e.g., Ex d, EEx d, XP) and select corresponding spare parts.
  • Seal material must be compatible with process media and environmental conditions.
  • Electronic inserts must match the supply voltage and output signal type.
  • Cable length and type (standard/armored) should be selected according to installation distance.

For a complete spare parts list or technical data, please refer to the original manufacturer's catalog or contact the supplier.