FTI55 Spare Parts List: Selection Guide for Aluminum Covers, Electronic Inserts, and Sealing Rings

This article summarizes common spare parts for Liquicap M FTI55/FTI56 and other instruments, including housing covers, sealing components, electronic inserts, and installation accessories. Each spare part lists the order number, specification description, and applicable models, making it easy for engineering technicians and procurement personnel to quickly find and select parts.

I. Housing Covers and Sealing Components

Housing covers protect the internal electronic components of the instrument. Depending on the housing material and model, the corresponding cover and sealing ring must be selected. The following is a list of common spare parts.

1.1 Aluminum Covers (with O-ring)

Aluminum covers are suitable for aluminum housings and come standard with EPDM O-rings, providing protection. Different housing sizes and models require different order numbers.

Order Number Specification Applicable Model/Housing
52002698 Aluminum cover, O-ring EPDM Aluminium housing F13, Ex d
52002699 Aluminum cover, O-ring EPDM Aluminium housing F17
52006903 Aluminum cover, O-ring EPDM Liquiphant M/S, Liquicap M, Soliphant M
52007103 Aluminum cover, O-ring EPDM Aluminium housing T13 (terminal compartment)

1.2 Plastic Covers and Stainless Steel Covers

Plastic covers are suitable for polyester housings, and stainless steel covers are suitable for stainless steel housings. Both must be used with the corresponding sealing gaskets.

Order Number Specification Applicable Housing
52025606 Plastic cover, Gasket EPDM Polyester housing
52027000 Stainless steel cover, Gasket 67.5x2.9x1.5 VMQ/PTFE Stainless steel housing F15

1.3 Sealing Components and O-rings

Sealing components are used to seal the housing cover to ensure the protection rating. Different housing materials and sizes require the corresponding seals.

Order Number Specification Applicable Housing
52004137 O-ring, Cover seal set Polyester housing F16
52004277 Sealing set (including 10x O-ring 70.0x3.0 EPDM)
52008495 Sealing set, for cover
52028179 Gasket, Profile gasket for cover Stainless steel housing F15

II. Electronic Inserts

Electronic inserts are the core components of the instrument, responsible for signal processing and output. Different output types and supply voltages require different inserts. The following is a list of common electronic inserts.

Order Number Specification Applicable Model
71025814 19-253VAC, 19-55VDC Liquicap M FTI51/52
71025815 Liquicap M FTI51/52
71025816 Liquicap M FTI51/52
71025819 3-wire PNP Liquicap M FTI51/52
71025820 3-wire Liquicap M FTI51/52
71042887 2-wire FTI51/FTI52/FTI55/FTI56, FTI77
71100895 8/16mA, 11-36VDC FTI51/FTI52/FTI55/FTI56, FTI77

III. Installation Accessories and Process Seals

Installation accessories include separate cables, mounting kits, and sun protection covers. Process seals are used for process connections. Correct selection ensures long-term stable operation of the instrument.

3.1 Separate Cables and Mounting Kits

  • 71084478: Separate cable, length 6m, used to connect the sensor to the separate housing, suitable for FTI51/FTI52/FTI55/FTI56, FTI77.
  • 919806-1000: Mounting kit (2"/pipe 38_V4A), suitable for FMI51/FMI52, FTG20, FTI51/FTI52, FTI55/FTI56, FTI77, FTM50/FTM51/FTM52.

3.2 Sun Protection Covers

Sun protection covers protect the instrument from direct sunlight and extend its service life. The following are two common sun protection covers.

  • 71040497: Suitable for FMI51/FMI52, FTI51/FTI52/FTI55/FTI56, FTI77, FTL50/FTL50H/FTL51/FTL51C/FTL51H, FTL70/FTL71, FTL80/FTL81/FTL85, FTM20/FTM21, FTM50/FTM51/FTM52.
  • 71127760: Suitable for FDR56, FMI21, FMI51/FMI52, FQR56, FTI51/FTI52/FTI55/FTI56, FTI77, FTL50/FTL50H/FTL51/FTL51C/FTL51H, FTL70/FTL71, FTL80/FTL81/FTL85, FTM20/FTM21, FTM50/FTM51/FTM52, FTR20, FTW31/FTW32/FTW33.

3.3 Process Sealing Rings

Process sealing rings are used for process connections G1 and G1-1/2 to ensure leak-free sealing.

Order Number Specification Applicable Process Connection
52014048 Sealing ring, Process gasket G1
52014047 Sealing ring, Process gasket G1-1/2

All the above spare parts are suitable for Liquicap M FTI55/FTI56 and other series instruments. When selecting, please confirm the housing model and process connection specifications. For more information, please refer to the product manual or contact technical support.