TH55 Spare Parts List Overview
The TH55 spare parts list lists commonly used spare parts for industrial temperature instruments, including gaskets, displays, filter ports, etc. Correct selection of spare parts can extend equipment life and reduce downtime.
Main Spare Parts List
| Order Number | Specification | Description |
|---|---|---|
| 52028179 | Gasket | Profile gasket for cover, Stainless steel housing F15 |
| 60017971 | Display | Display LC for TA20J |
| 71043745 | Atmospheric compensation filter port | Consists of: filter plug plastic, Pressure compensation filter, O-ring. Usage: housing F15. Non Ex. |
| 71310423 | Display housing fixing kit (3 pcs) | Pack = 3 piece |
| 51006845 | Cable gland | Cable gland NPT 1/2, D4-8.5, IP68 |
| 51007995 | Mounting bracket | Mounting bracket SS316L, tube 1,5-3" |
| 71386275 | TMT162- | Spare part TMT162 |
| 71044062 | Device package | 2x screws, 1x sealing CDI-connector |
iTEMP Temperature Transmitter Series
The iTEMP series temperature transmitters offer multiple models suitable for different application scenarios. The following are common models and their features.
Spare Part Kits
- TMT142X-HI - Spare part TMT142X
- TMT142X-HL - Spare part TMT142X
- TMT162X-HE - Spare part TMT162X
- TMT162X-HF - Spare part TMT162X
- TMT162X-HI - Spare part TMT162X
- TMT162X-HL - Spare part TMT162X
- TMT142X-DA - Spare part TMT142X
- TMT142X-DB - Spare part TMT142X
- TMT142X-DC - Spare part TMT142X
- TMT162X-DA - Spare part TMT162X
- TMT162X-DB - Spare part TMT162X
- TMT162X-DC - Spare part TMT162X
Accessories
- TMT162A-MA - TMT162A accessories
- TMT162A-MB - TMT162A accessories
- TMT162A-MD - TMT162A accessories
Thermocouples and Enclosures
- TU121- - TC Insert TU121, General Purp, US Style. Spare part. Thermocouple Insert spring loaded. Thermocouple comply with EMF tables of ASTM E-230 and IEC60584. Color codes per ASTM E-230.
- TU401- - Enclosure TU401, US Style
- XPT0004- - Spare Parts Kit Cover TA30R (cover of connecting head)
Terminal Heads
Terminal heads are used to install transmitters, providing protection and connection.
- TA30H- - Terminal Head TA30H. Retainer for terminal block or head transmitter + optional display. Design: explosion proof. Cover: screwed, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing). Protection Ex d/XP: IP66/67 (housing).
- TA30R- - Terminal Head TA30R. Retainer for terminal block or head transmitter + optional display. Cover: screwed, optional window. Material: Stainless Steel 316L. Colour: Steel (no coating). Ambient Temp.: -50...85/130 oC (display/standard). Protection: IP66/68, NEMA4X; IP69K (housing). :: easy wiring through best accessibility. :: compact desing and low weight.
Electronic Modules and Housings
- TMT142E- - Electronic TMT142E
- TMT142G- - Housing TMT142G
- TMT162E- - Electronic TMT162
- TMT162G- - Housing TMT162
Configuration Tools
- TXU10- - Configuration Kit TXU10 for PC-programmable devices. set-up programme+interface cable for PC with USB-Port.
- READWIN- - Readwin 2000 Operation + Read. software
Transmitter Models
The following are iTEMP series transmitters, some models are being phased out, please pay attention to availability.
- TMT181- - **iTEMP TMT181, Head Transmitter PCP. Product being phased out, limited availability. Temperature transmitter,PC-programmable. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanic isolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.
- TMT182- - **iTEMP TMT182, Head Transmitter HART. Product being phased out, limited availability. Temperature transmitter, Protocol HART. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanicisolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.
- TMT71- - iTEMP TMT71, Transmitter 4-20mA. 2-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification:Pt100, 4-wire, 0...+100oC.
- TMT72- - iTEMP TMT72, Transmitter HART. 2-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification:Pt100, 4-wire, 0...+100oC.
- TMT82- - iTEMP TMT82, Transmitter HART. 2-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.
- TMT84- - iTEMP TMT84, Transmitter PA. Dual sensor input. Advanced diagnostics:sensor monitoring. PROFIBUS PA Profile 3.02. Galvanic isolation 2kV. Application: RTD, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.
- TMT85- - iTEMP TMT85, Transmitter FF. Dual sensor input. Advanced diagnostics: sensor monitoring. FOUNDATION Fieldbus protocol. Galvanic isolation 2 kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.
Display Units and Communication Modules
- TID10- - Display Unit Head Transmitter to plug on. Dot-Matrix measured value display. 12 DIP-switches buttom side. Settings: FF: Simulation, Write Lock. PA: Bus address, Write Lock. Compatible: TMT85, TMT84, TMT82, TMT71, TMT72.
- FXA195- - Commubox FXA195. Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508.
Selection Considerations
When selecting a temperature transmitter, consider signal type, communication protocol, protection class, and certification requirements. For example, HART protocol is suitable for most process control, while PROFIBUS PA and FOUNDATION Fieldbus are suitable for fieldbus systems. Protection classes such as IP66/68 ensure reliability in harsh environments.
For safety-critical applications, models supporting SIL 2/3 can be selected, such as TMT82. Spare parts such as gaskets and displays should be regularly inspected and replaced to ensure measurement accuracy.
Conclusion
The TH55 spare parts list and iTEMP transmitter selection guide provided in this article can help engineers and procurement personnel quickly locate the required spare parts and models. Correct selection and maintenance are key to ensuring the stable operation of industrial temperature measurement systems.