TC13 Series Temperature Instrument Spare Parts Overview

The TC13 series temperature instruments are widely used in industrial process measurement, and their spare parts are numerous. Correct selection is crucial for equipment maintenance. This article organizes the spare parts list by function, including order numbers, specifications, and technical parameters, for quick reference by engineering technicians and procurement personnel.

TC13 Spare Parts List

Common Spare Parts and Consumables

Heat Transfer Oil and Seals

  • Heat transfer oil FDA certified 30g: Order No. 71249291, suitable for food and pharmaceutical industries.
  • Heat transfer oil HSC 340, 100g: Order No. 71312729, high-temperature heat transfer medium.
  • Gasket: Order No. 52028179, Profile gasket for cover, dedicated for stainless steel housing F15.
  • Seal: Order No. 71367427, packaging unit 10 pieces.
  • Seal kit: Order No. 71182602, includes 5x O-ring 3.69x1.78 and 5x O-ring 74.7x2.75.
  • O-ring spare parts kit TA20R: Order No. 71586415, specification 44.17x1.78 EPDM, laboratory grade, black, 5 pieces/pack.

Display and Connection Components

  • Display: Order No. 60017971, Display LC for TA20J.
  • Atmospheric compensation filter port: Order No. 71043745, includes filter plug, pressure compensation filter, O-ring, for F15 housing, non-explosion-proof.
  • Connector: Order No. 71313382.
  • Device package: Order No. 71044061, includes 2x screws, 2x springs, 2x spring washers, 1x sealed CDI connector.
  • Ceramic terminal: Order No. 71111510 and 71111514.

Extension Wires and Thermocouples

  • Extension wire TC IEC 2x type K: Order No. 71389488, L=180mm, 3 pieces/pack.
  • Extension wire TC IEC 2x type J: Order No. 71389497, L=180mm, 3 pieces/pack.
  • Thermocouple core TPC100: Replaceable insert (MgO).
  • Protection tube TW13: Flange connection, compliant with DIN 43772 /2F+3F, welded type.

Temperature Transmitters and Modules

Module Temperature Transmitter TMT84

  • Dual sensor input, advanced diagnostics: sensor monitoring.
  • Galvanic isolation 2kV, applications: RTC, TC, Ohm, mV.
  • Current consumption: 11 mA, mounting: type B head, DIN43729.
  • Factory settings: CH1: Pt100, 3-wire, oC; CH2: inactive, customizable.

Module Temperature Transmitter TMT85

  • Dual sensor input, advanced diagnostics.
  • FOUNDATION Fieldbus protocol (ITK 5.0).
  • Galvanic isolation 2kV, applications: RTC, TC, Ohm, mV.
  • Current consumption: 11 mA, mounting: type B head, DIN43729.
  • UL certified, CSA general purpose.

Temperature Transmitter Display TID10

  • Plug and play, dot matrix measured value display.
  • 12 DIP switches at the bottom, settings: FF simulation, write protection; PA bus address, write protection.
  • Compatible with TMT85, TMT84.

Module Temperature Transmitter TMT182

  • HART protocol, applications: RTD, TC, Ohm, mV.
  • Two-wire 4-20mA, SIL2, galvanic isolation.
  • Fault response: NAMUR NE 43.
  • Mounting: type B head, DIN43729, UL certified, GL marine.

Module Temperature Transmitter TMT82

  • Two-wire temperature transmitter, dual universal sensor input.
  • Galvanic isolation 2kV (input/output).
  • Applications: RTD, TC, Ohm and mV.
  • Drift detection and sensor backup, high reliability.
  • Optional SIL 2/3 safety applications (IEC61508).

Terminal Boxes and Accessories

Terminal Box TA20A

  • Phased-out product, limited stock.
  • Used for mounting measuring inserts or connection sockets, can be mounted on brackets or protection tubes.
  • Material: aluminum epoxy resin coating, ambient temperature: up to +100°C, ATEX: +95°C.

Terminal Box TA20B

  • Connection head, used for mounting measuring inserts or connection sockets.
  • Material: black polyamide, ambient temperature: up to +80°C, protection class: IP65.

Terminal Box TA21E

  • Used for fixing terminal blocks or head transmitters, screw-on cover.
  • Material: aluminum, max temperature: +100°C; ATEX +95°C, protection class: IP65.

Terminal Head TA30A

  • Used for fixing terminal blocks or head transmitters + optional display.
  • Cover: low, hinged, optional window.
  • Material: aluminum, polyester powder coating, color: body blue, cover gray.
  • Ambient temperature: -50...150°C, protection class: IP66/68, NEMA 4X.

Terminal Head TA30D

  • Used for fixing 2 head transmitters or terminal blocks.
  • Cover: high, hinged.
  • Material: aluminum, polyester powder coating, color: body blue, cover gray.
  • Ambient temperature: -50...150°C, protection class: IP66/68, NEMA 4X.

Terminal Box TA30P

  • Used for fixing 2 head transmitters or terminal blocks.
  • Cover: high, hinged.
  • Material: polyamide PA12 antistatic, color: black.
  • Ambient temperature: -40...120°C, protection class: IP65.

Communication Interface FXA195

  • Modem, connects HART field devices to computer via USB.
  • For intrinsically safe signal circuits, SIL2, IEC61508.

Commissioning Package and Software

  • Readwin 2000 commissioning package: operation + reading software.
  • Instrument commissioning package TXU10: for devices programmable via PC, program settings + USB cable.

Other Accessories

  • Spare RFID TAG: includes RFID tag, fixing wire, crimp sleeve.
  • Service: Order No. DIENST-.

Notes on Spare Parts Selection

  • Confirm equipment model and spare parts compatibility, e.g., TMT84/TMT85 compatible with TID10.
  • Pay attention to explosion-proof area restrictions, e.g., TA20A max +95°C under ATEX.
  • Check protection class requirements, e.g., IP65, IP66/68.
  • Verify packaging units to avoid insufficient procurement quantities.
  • Prefer original spare parts to ensure performance and safety.