TAF16 Spare Parts List Overview
This article provides complete ordering information for the TAF16 spare parts list, covering extension wires, flanges, compression fittings, seals, and device packages. All spare parts list order numbers, specifications, and key parameters for quick selection by engineering technicians and procurement personnel.
Extension Wires
Extension wires are suitable for thermocouple signal transmission, comply with IEC standards, have a length of 180mm, and are packed 3 pieces per package.
| Order Number | Specification |
|---|---|
| 71389488 | Extension wire TC IEC 2x type K, L=180mm, Packing unit: 3 pieces |
| 71389497 | Extension wire TC IEC 2x type J, L=180mm, Packing unit: 3 pieces |
| 71389508 | Extension wire TC IEC 2x type N, L=180mm, Packing unit: 3 pieces |
| 71389514 | Extension wire TC IEC 2x type S/R, L=180mm, Packing unit: 3 pieces |
Flanges
Flanges are used for temperature sensor installation, with a maximum temperature of 400°C and material of cast iron. Note: Mating flange and gasket not provided.
| Order Number | Type | Specification |
|---|---|---|
| 60000516 | Oval flange | Maximum temperature 400°C DIN 43734, Material in cast iron, Mating flange and gasket not provided. Dimension: A=23mm, C=90mm, B=70mm |
| 60008385 | Loose flange | Maximum temperature 400°C, Material in cast iron, Mating flange and gasket not provided. Dimension: A=16mm, C=75mm, B=55mm |
| 71039792 | Oval flange | Maximum temperature 400°C, Material cast iron. Counter flange and gasket not provided. No gas-tight connection. Dimension: d2=29mm, a=90mm, c=70mm. Clampable diameter from 27mm to 28mm. |
Compression Fittings
Compression fittings are used for pipe connection, with a maximum temperature of 350°C and maximum pressure of 1 bar. Materials include stainless steel and 316Ti (1.4571).
| Order Number | Specification |
|---|---|
| 60020836 | Maximum temperature 350°C, Maximum pressure 1 bar. Material in stainless steel. Dimension: A=G 3/4", d=22mm, Wr=41 |
| 60021425 | Maximum temperature 350°C, Maximum pressure 1 bar. Material in stainless steel. Dimension: A=G1"1/2, d=22mm, Wr=55 |
| 60021757 | Maximum temperature 350°C, Maximum pressure 1 bar. Material in stainless steel. Dimension: A=G1", d=22mm, Wr=41 |
| 71001827 | Maximum temperature 350°C. Maximum pressure 1 bar. Material 316Ti (1.4571). For Pipe diameters 26,7/27mm. Dimension: A=G 1", d=28mm, Wr=46. |
| 71031438 | Maximum temperature 350°C. Maximum pressure 1 bar. Material 316Ti (1.4571). For pipe diameter 13.7...14mm. Dimension: A=G3/4", d=15.5mm, Wr=36. |
| 71125353 | Maximum temperature 350°C. Maximum pressure 1 bar. Material 316Ti (1.4571). For Pipe diameter 28mm. Dimension: A=G 1 1/4", d=29mm, Wr=55. |
| 71125354 | Maximum temperature 350°C. Maximum pressure 1 bar. Material 316Ti (1.4571). For Pipe diameters 28mm. Dimension: A=G 1 1/2", d=29mm, Wr=55. |
| 71125362 | Maximum temperature 350°C. Maximum pressure 1 bar. Material 316Ti (1.4571). For Pipe diameter 18mm. Dimension: A=G 3/4", d=19mm, Wr=36. |
| 71125364 | Maximum temperature 350°C. Maximum pressure 1 bar. Material 316Ti (1.4571). For Pipe diameter 18mm. Dimension: A=G 1", d=19mm, Wr=41. |
| 71244062 | Maximum temperature 350°C. Maximum pressure 1 bar. Material 316Ti (1.4571). For pipe diameter 13.7...14mm. Dimension: A=G1/2", d=15.5mm, Wr=36. |
| 71244070 | Compression fitting |
| 71244071 | Compression fitting |
| 71421272 | Compression fitting G1" 15.5.mm, 316Ti. Maximum temperature 350°C. Maximum pressure 1 bar. Material 316Ti (1.4571). For pipe diameter 13.7...14mm. Dimension: A=G1", d=15.5mm, Wr=41. |
Seals and Device Packages
Seals and device packages are used for maintenance and installation to ensure system sealing and integrity.
- 71182602 Seal: 5x O-ring 3.69x1.78, 5x 0-ring 74.7x2.75
- 71044061 Device package: 2x screws, 2x springs, 2x spring rings, 1x sealing CDI-connector
Temperature Transmitters and Accessories
The following is selection information for temperature transmitters, terminal heads, and configuration software compatible with TAF16.
Thermocouple Insert TPC100
TPC100 thermocouple insert, replaceable insert (MgO), model code: TPC100-, specific configurations such as A, M, XX, 2, C, F, etc.
Configuration Packages
- READWIN-: Readwin 2000 configuration package, Readwin 2000 Operation + Read. software, code 1, AA
- TXU10-: Instrument configuration package TXU10, for devices programmable via PC, program settings + connection cable for PC with USB interface, code AA, AC, AD
Terminal Heads
| Model | Description |
|---|---|
| TA30A- | Retainer for terminal block or head transmitter + optional display. Cover: low, hinged, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150°C (housing). Protection: IP66/68, NEMA 4X (housing). |
| TA30D- | Retainer for 2 head transmitters or terminal blocks. Cover: high, hinged. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150°C (housing). Protection: IP66/68, NEMA 4X (housing). |
Temperature Transmitters
| Model | Description |
|---|---|
| TMT71- | 2-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification: Pt100, 4-wire, 0...+100°C. |
| TMT72- | 2-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification: Pt100, 4-wire, 0...+100°C. |
| TMT82- | 2-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Presetting failure current high. Highly reliable due to drift detection and sensor back up. Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508. |
| TMT84- | Dual sensor input. Advanced diagnostics: sensor monitoring. Galvanic isolation 2kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. Factory setup: CH1: Pt100, 3-wire, °C; CH2: inactive. Differing configuration optional selectable. |
| TMT85- | Temperature transmitter with dual sensor input and advanced diagnostics for sensor monitoring. FOUNDATION Fieldbus protocol (ITK 5.0). Galvanic isolation 2 kV (sensor input to the output). Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. UL listed, CSA General Purpose. |
The above is the TAF16 spare parts list and compatible accessory selection information. For detailed technical data or ordering, please contact us.