TC63 Series Spare Parts Overview

The TC63 series is a commonly used instrument in industrial temperature measurement. Its spare parts include heat transfer oil, terminal blocks, inserts, protection tubes, transmitters, and commissioning tools. Correct selection and ordering are crucial to ensuring measurement accuracy and equipment reliability. The following spare parts list is organized by category for easy reference by engineering technicians and procurement personnel.

Spare Parts Details

Order NumberSpecificationRemarks
71249291Heat transfer oil FDA certified 30g-
71312729Heat transfer oil HSC 340, 100g-
71044061Equipment package2x screws, 2x springs, 2x spring rings, 1x sealing CDI-connector
71111510Ceramic terminal blockC
71111514Ceramic terminal blockA
TPC100-Thermocouple insert TPC100Replaceable insert (MgO)
TPC300-Thermocouple insert TPC300Replaceable insert (MgO) to use with TC6x line.
TA540-Protection tube TA540flange connection or screw in. Thermometer connection female, welded version.
TA541-Protection tube TA541flange connection or screw in. Thermometer connection male, welded version.
TMT84-Modular temperature transmitter TMT84Dual sensor input. Advanced diagnostics: sensor monitoring. Galvanic isolation 2kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. Factory setup: CH1: Pt100, 3-wire, oC; CH2: inactive; Differing configuration optional selectable.
TMT85-Modular temperature transmitter TMT85Temperature transmitter with dual sensor input and advanced diagnostics for sensor monitoring. FOUNDATION Fieldbus protocol (ITK 5.0). Galvanic isolation 2 kV (sensor input to the output). Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. UL listed, CSA General Purpose.
TID10-Temperature transmitter display TID10to plug on. Dot-Matrix measured value display. 12 DIP-switches buttom side. Settings: FF: Simulation, Write Lock. PA: Bus address, Write Lock. Compatible: TMT85, TMT84.
READWIN-Readwin 2000 commissioning package READWINReadwin 2000 Operation + Read. software
TXU10-Instrument commissioning package TXU10For devices that can be programmed and commissioned via PC. Program setup + connection cable for PC with USB interface
FXA195-Communication interface FXA195Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508.
TA30H-Terminal box TA30HRetainer for terminal block or head transmitter + optional display. Design: explosion proof. Cover: screwed, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50#150 oC (housing). Protection: IP66/68, NEMA 4X (housing). Protection Ex d/XP: IP66/67 (housing).
TMT82-Modular temperature transmitter TMT822-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.

Key Spare Parts Selection Guide

Heat Transfer Oil

  • FDA certified heat transfer oil (30g): Suitable for food and pharmaceutical industries, ensuring safety and compliance.
  • HSC 340 heat transfer oil (100g): Good high-temperature stability, suitable for industrial high-temperature environments.

Terminal Blocks and Inserts

  • Ceramic terminal blocks: High temperature resistance, good insulation performance, divided into C type and A type, order numbers 71111510 and 71111514 respectively.
  • Thermocouple inserts: TPC100 and TPC300, using MgO replaceable inserts, TPC300 specifically designed for the TC6x series.

Protection Tubes

  • TA540: Flange connection or threaded connection, thermometer connection female thread, welded version.
  • TA541: Flange connection or threaded connection, thermometer connection male thread, welded version.

Temperature Transmitters

  • TMT84: Dual sensor input, advanced diagnostics, galvanic isolation 2kV, suitable for RTC, TC, Ohm, mV, current consumption 11mA, mounting head form B, DIN43729.
  • TMT85: Supports FOUNDATION Fieldbus protocol, dual sensor input, galvanic isolation 2kV, UL certified, CSA General Purpose.
  • TMT82: 2-wire, dual universal sensor input, galvanic isolation 2kV, supports RTD, TC, Ohm, mV, with drift detection and sensor backup, optional SIL2/3.

Accessories and Commissioning Tools

  • TID10 display: Plug and play, dot matrix display, 12 DIP switches, compatible with TMT85/TMT84.
  • Readwin 2000 commissioning package: Operation and read software.
  • TXU10 commissioning package: For PC programming devices, includes USB connection cable.
  • FXA195 communication interface: USB to HART modem, supports SIL2, IEC61508.
  • TA30H terminal box: Explosion-proof design, aluminum housing, polyester powder coating, protection class IP66/68, NEMA 4X, Ex d/XP protection IP66/67.

Ordering Notes

Please select the appropriate specification of spare parts according to the actual application environment and confirm the complete order number. For explosion-proof applications, choose products with corresponding certifications, such as the TA30H terminal box. For safety-critical applications, it is recommended to use transmitters that support SIL certification, such as the TMT82.