CA71SI Silica Analyzer Spare Parts Overview

The CA71SI silica analyzer is an important instrument in industrial water quality analysis, and the selection of its spare parts directly affects measurement accuracy and operational stability. This article provides a complete spare parts list, including reaction reagents, calibration solutions, spare parts kits, and various tubing connectors. Engineering technicians and procurement personnel can quickly locate the required components based on order numbers.

Reaction Reagents and Calibration Solutions

CA71SI Reaction Reagents (CAY643-)

The reagent kit contains three components, SI 1, SI 2, and SI 3, used for the chemical color reaction of the CA71SI analyzer. This product is classified as hazardous material, and transportation and storage must comply with relevant regulations.

Order NumberSpecification Description
CAY643-V00Reaction reagent kit, containing SI 1, SI 2, SI 3
CAY643-V01Reaction reagent kit, containing SI 1, SI 2, SI 3
CAY643-V10Reaction reagent kit, containing SI 1, SI 2, SI 3
CAY643-Y99Reaction reagent kit, containing SI 1, SI 2, SI 3
CAY643-AAReaction reagent kit, containing SI 1, SI 2, SI 3
CAY643-YYReaction reagent kit, containing SI 1, SI 2, SI 3
CAY643-EReaction reagent kit, containing SI 1, SI 2, SI 3
CAY643-HReaction reagent kit, containing SI 1, SI 2, SI 3
CAY643-LReaction reagent kit, containing SI 1, SI 2, SI 3

CA7xSI Calibration Solution (CAY642-)

Calibration solutions are used for calibrating the CA7x series silica analyzers to ensure measurement accuracy. Multiple specifications are available to meet calibration needs at different concentrations.

Order NumberSpecification Description
CAY642-V00Calibration solution
CAY642-V01Calibration solution
CAY642-V10Calibration solution
CAY642-V99Calibration solution
CAY642-C00Calibration solution
CAY642-C01Calibration solution
CAY642-C05Calibration solution
CAY642-C10Calibration solution
CAY642-C50Calibration solution
CAY642-C99Calibration solution
CAY642-AACalibration solution
CAY642-YYCalibration solution
CAY642-ECalibration solution
CAY642-HCalibration solution
CAY642-LCalibration solution

Analyzer Spare Parts Kits

CAV740- Spare Parts Kit

The CAV740 spare parts kit is used for the maintenance of CA7X series analyzers. It includes connectors and connecting tubes, with optional inlet and outlet tubes.

Order NumberSpecification Description
CAV740-4Spare parts kit, including connectors and connecting tubes
CAV740-6Spare parts kit, including connectors and connecting tubes
CAV740-9Spare parts kit, including connectors and connecting tubes
CAV740-ASpare parts kit, including connectors and connecting tubes
CAV740-BSpare parts kit, including connectors and connecting tubes, with inlet and outlet tubes
CAV740-CSpare parts kit, including connectors and connecting tubes, with inlet and outlet tubes
CAV740-YSpare parts kit, including connectors and connecting tubes

Other Spare Parts

  • 51512078: CA71SI-A photometer kit
  • 71180495: Float switch level detection
  • 51512101: CA mixing unit, 2 pieces
  • 51506495: CA tubing connector 1.6*1.6
  • 51506490: CA tubing connector 1.6*1.6*1.6
  • 51512096: CA Y-shaped tubing connector 1.6x1.6x1.6
  • 51506491: CA tubing connector 3.2*1.6
  • 51506492: CA tubing connector 6.4*3.2
  • 51506493: CA tubing connector 6.4*6.4*6.4
  • 51506494: CA tubing connector 1.6*1.6*1.6
  • 51518417: Threaded nipple 3.2x3.2x3.2 mm, 10 pieces
  • 51511087: CA tubing connector 3.2*3.2, 10 pieces
  • 51505778: CA photometer glass tube fitting
  • 71017654: Peristaltic pump lubricant
  • 51506437: CA72 peristaltic pump tubing kit, black/black
  • 71114613: CA72 peristaltic pump tubing kit
  • 51511183: CA70 peristaltic pump tubing kit, purple/white
  • 71404720: Hose ID 1.6 mm
  • 71404721: 7.5 m long C-Flex tubing accessory with ID 3.2 mm
  • 71404722: 7.5 m long C-Flex tubing accessory with ID 6.4 mm
  • 71404719: 15 m long Norprene tubing accessory with ID 1.6 mm

Selection and Ordering Recommendations

When ordering, please verify the compatibility of the order number with the instrument model. In particular, reagents and calibration solutions require attention to hazardous material transportation requirements. It is recommended to regularly maintain and replace peristaltic pump tubing and tubing connectors to ensure long-term stable operation of the analyzer.