8E3B Mass Flow Meter Overview

8E3B mass flow meter is a high-precision direct mass flow measurement instrument based on the Coriolis force principle. It can directly output mass flow without additional temperature and pressure compensation, and is suitable for liquid, gas, and multiphase flow measurement. This article provides the 8E3B Chinese manual download and summarizes key points for selection and use.

Download 8E3B Chinese Manual Click to download: 8E3B Chinese Manual.pdf

Working Principle and Technical Advantages

Coriolis Measurement Principle

When fluid flows through the vibrating measuring tube, a Coriolis force proportional to the mass flow is generated. By detecting the phase difference or amplitude change of the tube, the mass flow can be directly calculated. This principle is not affected by fluid temperature, pressure, viscosity, and other parameters.

Core Advantages

  • Direct mass flow measurement, no temperature and pressure compensation required
  • High precision: typical accuracy up to ±0.1% (liquid)
  • Wide turndown ratio: typically 100:1 or more
  • Can measure high viscosity, gas-containing, non-Newtonian fluids
  • Simultaneously outputs mass flow, density, temperature, and volumetric flow

Main Technical Parameters

The following are typical parameters of the 8E3B series. Refer to the manual for specific details.

ParameterTypical ValueRemarks
Nominal diameter rangeDN1 ~ DN300Optional
Mass flow accuracy±0.1% ~ ±0.2%Liquid
Density accuracy±0.001 g/cm³
Temperature range-50°C ~ +200°CHigh-temperature type optional
Pressure ratingPN40 ~ PN100Optional
Output signal4-20mA, pulse, HART, RS485
Protection classIP67 / IP68

Installation and Commissioning Steps

Installation Precautions

  • Ensure the pipeline is full to avoid bubble accumulation
  • The flow direction arrow must match the medium flow direction
  • Avoid installation near strong vibration or electromagnetic interference sources
  • For gas measurement, vertical installation or flag installation is recommended

Commissioning Process

  1. Check if the wiring is correct and the power supply voltage meets requirements
  2. After power-on, wait for warm-up, usually more than 30 minutes
  3. Enter the menu and set medium type, range, damping time
  4. Perform zero calibration: ensure the pipeline is full and static with no flow
  5. Verify that the output signal matches the host computer, and fine-tune if necessary

Common Issues and Maintenance

Common Troubleshooting

  • Zero drift: recalibrate zero, check if the pipeline is empty or has bubbles
  • Large measurement fluctuation: increase damping time, check for two-phase flow or vibration interference
  • No output signal: check power supply, fuse, and wiring terminals

Daily Maintenance Recommendations

  • Regularly check if the measuring tube is scaled or corroded
  • Online calibration is recommended every 12 months
  • Keep the instrument housing clean to prevent moisture from entering the wiring compartment

Selection and Procurement Points

When purchasing the 8E3B mass flow meter, please specify the following information:

  • Medium name, temperature, pressure, flow range
  • Required accuracy class and repeatability
  • Process connection type (flange, thread, clamp)
  • Explosion-proof requirements (Ex d, Ex ia, etc.)
  • Output signal and communication protocol

For complete technical details, please refer to the 8E3B Chinese Manual. The download link is at the beginning of this article.