RSG35 Chinese Manual Download
You can directly download the RSG35 Chinese manual to obtain complete technical materials and operation instructions.

Download RSG35 Chinese Manual.pdf
RSG35 Product Overview
RSG35 is an instrument widely used in industrial process control, featuring high precision and stability.
This manual covers installation, wiring, parameter setting, and troubleshooting, and is suitable for reference by engineering technicians and procurement personnel.
Core Features
- High-precision measurement: Meets the requirements of harsh industrial environments
- Multiple output signals: Supports protocols such as 4-20mA and HART
- Wide temperature operation: Adapts to -40℃~85℃ environments
- Protection rating IP67: Dustproof and waterproof, suitable for outdoor installation
Technical Parameters Overview
| Parameter Item | Specification |
|---|---|
| Measurement Range | 0~10MPa (customizable) |
| Accuracy Class | ±0.5% FS |
| Power Supply | 24V DC |
| Output Signal | 4-20mA / HART |
| Process Connection | G1/2, M20*1.5 |
| Protection Rating | IP67 |
Installation and Wiring Steps
- Installation location selection: Avoid vibration, corrosive gases, and strong electromagnetic interference sources.
- Mechanical installation: Use a suitable wrench to tighten the process connection to ensure sealing without leakage.
- Electrical wiring: Connect the power supply and signal wires according to the manual markings, and pay attention to polarity.
- Power-on inspection: Confirm that the power supply voltage is within the range of 24V DC±10%.
- Parameter setting: Adjust the range and damping through a hand-held communicator or HART communication.
Selection Precautions
- Media compatibility: Confirm that the wetted materials are compatible with the measured medium.
- Pressure range: The actual working pressure should not exceed 80% of the range.
- Ambient temperature: If the working temperature is exceeded, heat dissipation or insulation devices must be added.
- Certification requirements: Select explosion-proof or intrinsically safe types according to on-site needs.
Common Problems and Maintenance
Troubleshooting
- No output signal: Check whether the power supply and wiring are loose.
- Large measurement deviation: Recalibrate the zero point and range.
- Display fluctuation: Increase the damping time or check the grounding.
Regular Maintenance
- Check the seals and wiring terminals every six months.
- Perform accuracy calibration once a year.
- Use a damp cloth to clean the housing and avoid corrosive solvents.
For complete details, please download the RSG35 Chinese Manual.pdf above.