Overview of Hach CDC40103 Conductivity Electrode

The CDC40103 is a standard Intellical series conductivity electrode manufactured by HACH (USA), with a 3-meter cable. Designed for laboratory use, it can measure conductivity, salinity, resistivity, and total dissolved solids (TDS) in wastewater, drinking water, and general water quality. Used with HQ series meters, it provides accurate and stable measurement results.

Hach CDC40103 Conductivity Electrode

Core Functions and Advantages

Intelligent Calibration Management

Each Intellical electrode independently stores calibration history and settings. When replacing electrodes, there is no need to re-enter parameters, greatly reducing calibration workload. The meter automatically recognizes the probe and reads historical information, minimizing human error.

Ready to Use

Calibrated at the factory, it is ready to use out of the box. If the electrode needs recalibration, the meter proactively reminds the user, ensuring reliable measurements at all times.

Waterproof and Durable

The standard electrode is waterproof for 24 hours at a depth of 3 meters (liquid-filled electrodes must not be immersed in deep water). Rugged electrodes offer longer cables to suit different field requirements.

Details of Hach Conductivity Electrode

Model and Selection Guide

Hach conductivity electrodes are available in standard and rugged types with various cable lengths to meet diverse application scenarios.

TypeModelCable LengthApplication
StandardCDC401011 mRoutine laboratory measurement
StandardCDC401033 mLaboratory and light field use
RuggedCDC401055 mField and harsh environments
RuggedCDC4011010 mDeep water or remote measurement
RuggedCDC4011515 mDeep water or remote measurement
RuggedCDC4013030 mDeep water or remote measurement

Compatible Meters and Kits

The CDC40103 can be flexibly paired with Hach HQ series portable meters. Common kit configurations include:

  • HQ30d53203000: HQ30d meter + CDC40103 standard conductivity electrode (3 m cable)
  • HQ30d53201000: HQ30d meter + CDC40101 standard conductivity electrode (1 m cable)
  • HQ30d53215000: HQ30d meter + CDC40105 impact-resistant conductivity electrode (5 m cable)
  • HQ30d53103203: HQ30d meter + PHC10103 pH electrode (3 m) + CDC40103 conductivity electrode (3 m)

In addition, HQ meters automatically recognize Intellical smart probes, retain calibration history, reduce setup time, and ensure accurate data even in challenging samples or environments.

Hach HQ Meter and Electrode Kit

Usage and Maintenance Recommendations

  1. Before first use, inspect the electrode for damage.
  2. Connect the electrode to the HQ meter; the instrument automatically recognizes it and reads the calibration history.
  3. If calibration is prompted, follow the on-screen instructions to calibrate with standard solutions.
  4. After measurement, rinse the electrode with deionized water to avoid cross-contamination.
  5. For long-term storage, keep the electrode in dedicated storage solution.

Following these steps can extend electrode life and maintain measurement accuracy. For more information, consult a Hach expert or refer to the product manual.

Hach Electrode Maintenance

Ordering Information

The Hach CDC40103 conductivity electrode and accessories are in large stock and available for purchase. Please choose the appropriate cable length and kit configuration according to your actual needs.

Hach Conductivity Electrode in Stock