FIBERTRAC 32 Chinese Manual Overview

The FIBERTRAC 32 is a high-performance industrial instrument widely used in temperature measurement and control. This Chinese manual is intended to help users correctly install, operate, and maintain the device. Please read this guide carefully before use to ensure safe and efficient operation of the equipment.

Download FIBERTRAC 32 Chinese Manual.pdf

Product Features and Main Parameters

Core Features

  • High-precision measurement: Adopts advanced sensing technology to ensure accurate and reliable data.
  • Wide range: Adapts to the needs of various industrial environments.
  • Rugged and durable: High protection rating, suitable for harsh working conditions.
  • Easy to integrate: Supports multiple output signals for convenient connection to control systems.

Main Technical Parameters

ParameterSpecification
Measurement range-200°C ~ +600°C (optional)
Accuracy class±0.5% FS
Output signal4-20mA / HART / RS485
Power supply24V DC
Protection ratingIP67
Process connectionG1/2, M20×1.5, etc.

Installation and Wiring Guide

Installation Steps

  1. Confirm the installation position, avoiding strong vibration and direct radiation from heat sources.
  2. According to the process connection specification, screw the instrument into the installation point and ensure good sealing.
  3. Use a wrench to tighten, avoiding excessive force that may damage the threads.
  4. Check for leakage after installation and perform a pressure test if necessary.

Electrical Wiring

  • Disconnect the power supply before wiring to ensure safety.
  • Connect the power and signal lines according to the terminal markings, paying attention to polarity.
  • Shielded cables are recommended, with single-end grounding to reduce interference.
  • After wiring is completed, check the insulation resistance to confirm there is no short circuit.

Operation and Commissioning

Basic Operation

After power-on, the instrument performs a self-test, the display lights up and shows the current measured value. Parameter settings can be made through panel buttons or remote communication.

  • Zero calibration: Adjust the zero point under known conditions.
  • Range setting: Set the upper and lower limits according to actual needs.
  • Damping adjustment: Used to suppress signal fluctuation.

Commissioning Precautions

  • Ensure the process is in a safe state before commissioning.
  • After modifying parameters, verify that the output signal corresponds correctly.
  • Record the commissioning parameters for future maintenance.

Maintenance and Troubleshooting

Routine Maintenance

  • Regularly inspect the instrument appearance and clean surface dirt.
  • Check whether the wiring is loose and whether the seal is aging.
  • Perform calibration every six months to ensure accuracy.

Common Faults and Handling

Fault symptomPossible causeHandling method
No displayPower not connectedCheck the power supply line
Abnormal output signalIncorrect wiring or interferenceCheck wiring and add shielding
Large measurement deviationSensor failure or calibration requiredRecalibrate or replace the sensor

Safety Instructions

  • Only qualified personnel may operate and maintain this instrument.
  • Comply with local electrical safety regulations.
  • In explosive atmospheres, use intrinsically safe or flameproof products.
  • Do not modify the internal circuits of the instrument without authorization.