WEIGHTRAC 31 is a load cell widely used in industrial continuous weighing scenarios, suitable for belt scales, loss-in-weight scales, and batching systems. To facilitate on-site commissioning and maintenance, we provide the official Chinese manual PDF download.

WEIGHTRAC 31 Chinese Manual PDF Download Click to download: WEIGHTRAC 31 Chinese Manual.pdf

Product Overview and Core Advantages

WEIGHTRAC 31 adopts the strain gauge measurement principle and outputs standard signals, allowing seamless integration with PLCs and weighing instruments. Its compact structure and high protection rating make it suitable for harsh industrial environments such as dust and vibration.

  • High precision: Comprehensive accuracy up to ±0.02% FS, meeting trade settlement and process control requirements.
  • Strong overload capacity: Safe overload 150% FS, ultimate overload 300% FS.
  • Wide temperature range: Operating temperature -30℃~+70℃, temperature compensation range -10℃~+40℃.
  • Multiple capacities: Available in specifications such as 1t, 2t, 5t, 10t, 20t.

Technical Parameters Overview Table

ParameterSpecification
Rated capacity1t / 2t / 5t / 10t / 20t
Output sensitivity2.0±0.1% mV/V
Comprehensive accuracy±0.02% FS
Input impedance380±10Ω
Output impedance350±3Ω
Recommended excitation voltage5~15V DC
Protection ratingIP67 (optional IP68)
MaterialAlloy steel / stainless steel

Installation and Commissioning Steps

Pre-installation Inspection

  1. Verify that the sensor model, capacity, and drawings are consistent.
  2. Check for transportation damage and measure whether input and output impedances are normal.
  3. Confirm that the mounting surface is flat, clean, free of oil stains and burrs.

Mechanical Installation Key Points

  • Ensure the loading direction is consistent with the sensor force axis to avoid lateral forces.
  • Use high-strength bolts and tighten evenly in a diagonal sequence to the specified torque.
  • After installation, add a protective cover to prevent material impact and dust accumulation.

Electrical Connection and Calibration

  1. Connect excitation and signal wires according to the wiring diagram in the manual, and ground the shield at one end.
  2. Power on and warm up for 15 minutes, then record the no-load output.
  3. Use standard weights or substitutes for two-point calibration to correct zero and span.
  4. After calibration, recheck linearity and repeatability; the error should be less than 0.03% FS.

Common Faults and Troubleshooting

SymptomPossible CauseSolution
Output signal driftLarge temperature changes, loose wiringCheck temperature compensation, tighten wiring
Unstable zeroLateral force or installation stressReadjust installation position and torque
No signal outputCable break, missing excitationMeasure impedance, check power supply
Reduced accuracyOverload history, damaged elastomerReturn to factory for inspection or replace sensor

Selection and Procurement Recommendations

When purchasing WEIGHTRAC 31, determine the capacity and material based on actual load, installation space, and environmental conditions. It is recommended to reserve 20%~30% overload margin; for corrosive environments, give priority to the stainless steel version.

  • Capacity selection: The normal load should be between 30% and 70% of the rated capacity.
  • Accuracy grade: Choose ±0.02% FS for trade settlement, ±0.05% FS for process control.
  • Certification requirements: For explosion-proof occasions, choose intrinsically safe or flameproof types and verify certificates.
  • Accessory matching: It is recommended to also purchase mounting bases, spherical head bolts, and shielded cables.

For complete technical information, please download the WEIGHTRAC 31 Chinese Manual above, or contact the supplier for selection support.