Memosens CCS53E Spare Parts Overview
Memosens CCS53E is a digital sensor used for disinfection, drinking water, and process water measurement. To ensure its long-term stable operation, spare parts need to be replaced regularly. Below are common spare parts and their ordering information.
Adapter Kits
Adapter kits are used to connect the sensor to different types of holders or flow-through assemblies. Below are adapter kits compatible with the CCS5x and CCS5xD series.
| Order Number | Specification | Applicable Model |
|---|---|---|
| 71372025 | CCA250 adapter kit | CCS5x + CCS5xD |
| 71372026 | CYA112 adapter kit | CCS5x + CCS5xD |
| 71372027 | CCA151 adapter kit, including fixing ring, thrust ring, sealing ring | CCS5x + CCS5xD |
| 71554885 | Adapter kit, for CYA27-xxxB* | CCS5x(D/E) |
Note: The kit with order number 71372027 includes a fixing ring, thrust ring, and sealing ring, suitable for applications requiring a complete sealing assembly.
Maintenance Kits
Regular maintenance can extend sensor life. The following maintenance kit is suitable for the CCV05 model.
- CCV05-: Maintenance kit CCV05, for CCSxxD or fixed cable sensor CCSxx.
Calibration and Verification Tools
To ensure measurement accuracy, regular calibration is required. The following tools can be used for calibration and verification of disinfection loops.
Handheld DPD Colorimetric Calibration Instrument PF-3
- Order Number: 71257946
- Measuring Range: 0.05 - 6 mg/l (free chlorine and total chlorine)
- Application: Disinfection, drinking water, and process water
- Features: Handheld photometer, IP67 protection rating, compliant with ISO 7393 standard, includes DPD cuvettes, plastic case packaging, comes with free chlorine and total chlorine test kit.
- Purpose: Used for calibration and verification of disinfection loops.
Zero-Point Gel COY8
- Order Number: COY8-
- Purpose: Used for zero-point verification, calibration, and adjustment of oxygen and disinfection sensors.
- Applicable Sensors: Amperometric and optical sensors.
- Diameter: 12, 25, and 40 mm.
- Application Scenarios: Laboratory and field.
Selection and Ordering Guide
When ordering spare parts, please confirm the sensor model and the required spare part type. The following steps can help you quickly select:
- Confirm the sensor model (e.g., CCS53E).
- Select the adapter kit according to the application (refer to the table above).
- If maintenance is needed, select the maintenance kit CCV05.
- Select calibration tools according to the measurement parameter: DPD colorimetric method for chlorine, zero-point gel for oxygen and disinfection sensors.
- Check the order number and place the order.
Tip: Some spare parts may be updated, please refer to the latest catalog.