Overview of Conductivity and Resistivity Unit Conversion

In the fields of industrial instrumentation and water quality analysis, conductivity and resistivity are core parameters for evaluating the conductive properties of solutions. Different industries and instruments often use different units, such as S/m, mS/cm, µS/cm, Ω·m, Ω·cm, etc., so mastering unit conversion methods is crucial.

This article provides complete conversion formulas, coefficient tables, and online tools to help engineering technicians and procurement personnel quickly complete unit conversions and ensure accurate and consistent data.

Conductivity Unit Conversion

Conductivity indicates the conductive ability of a solution, and its SI unit is siemens per meter (S/m). Common units also include millisiemens per centimeter (mS/cm), microsiemens per centimeter (µS/cm), and picosiemens per meter (pS/m).

Conductivity Unit Conversion Relationships

UnitConvert to S/mConvert to mS/cmConvert to µS/cm
1 S/m11010000
1 mS/cm0.111000
1 µS/cm0.00010.0011
1 pS/m1e-121e-111e-8

Conductivity Conversion Steps

  1. Enter the conductivity value and select the original unit.
  2. Select the target unit.
  3. Click the "Convert Conductivity" button to obtain the result.

Conversion principle: first convert the value uniformly to S/m, then convert it to the target unit.

Resistivity Unit Conversion

Resistivity is the reciprocal of conductivity and indicates a material's ability to impede current. Its SI unit is ohm-meter (Ω·m). Common units also include ohm-centimeter (Ω·cm) and kilo-ohm-centimeter (kΩ·cm).

Resistivity Unit Conversion Relationships

UnitConvert to Ω·mConvert to Ω·cmConvert to kΩ·cm
1 Ω·m11000.1
1 Ω·cm0.0110.001
1 kΩ·cm1010001

Resistivity Conversion Steps

  1. Enter the resistivity value and select the original unit.
  2. Select the target unit.
  3. Click the "Convert Resistivity" button to obtain the result.

Conversion principle: first convert the value uniformly to Ω·m, then convert it to the target unit.

Conversion Between Conductivity and Resistivity

Conductivity (σ) and resistivity (ρ) are reciprocals of each other, and the relationship formulas are:

Conductivity (σ) = 1 / Resistivity (ρ)
Resistivity (ρ) = 1 / Conductivity (σ)

When using the interchange tool, enter the value and select the type (conductivity or resistivity) and unit, then click "Convert to Opposite Quantity" to obtain the corresponding result.

Interchange Examples

  • If the conductivity is 0.01 S/m, then the resistivity is 100 Ω·m.
  • If the resistivity is 10 Ω·cm, then the conductivity is 10 S/m (i.e., 10000 µS/cm).

Online Conversion Tools

For convenient and quick calculation, we provide the following online tools that support conductivity and resistivity unit conversion and interchange.

Conductivity Conversion Tool

Resistivity Conversion Tool

Conductivity and Resistivity Interchange Tool

Note: When using the tools, please ensure that valid values are entered. Results will be displayed in scientific notation with 6 significant figures.