电磁流量计 5H1B
Technical Data
CompareLiquids
| Measuring Principle | Electromagnetic |
| Product headline | Specialist for hygienic applications with an ultra-compact transmitter. Multivariable measurement of flow, temperature and conductivity. Dedicated to demanding applications in the food and beverage as well as in life sciences industries. |
| Sensor features | Flexible installation concept – numerous hygienic process connections. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts. Integrated temperature measurement. Sensor housing made of stainless steel (3-A, EHEDG). Wetted materials CIP, SIP cleanable. |
| Transmitter features | Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology. Robust, ultra-compact transmitter housing. High degree of protection: IP69. Local display available. |
| Nominal diameter range | DN 2 to 150 (¹⁄₁₂ to 6") |
| Wetted materials | Liner: PFA Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum Process Connections: stainless steel, 1.4404 (F316L); PVDF; PVC adhesive sleeve Seals: O-ring seal (EPDM, FKM, Kalrez), aseptic molded seal (EPDM, FKM, silicone) Grounding Rings: stainless steel, 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); tantalum |
| Measured variables | Volume flow, temperature, conductivity, mass flow, corrected volume flow, corrected conductivity |
| Max. measurement error | Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s) Volume flow (option) ±0.2 % o.r. ± 2 mm/s (0.08 in/s) |
| Measuring range | 0.06 dm³/min to 600 m³/h (0.015 to 2650 gal/min) |
| Max. process pressure | PN 40, Class 150, 20K |
| Medium temperature range | –20 to +150 °C (–4 to +302 °F) |
| Ambient temperature range | –40 to +60 °C (–40 to +140 °F) |
| Sensor housing material | 1.4301 (304), corrosion resistant |
| Transmitter housing material | Compact: AlSi10Mg, coated Compact/ultra‐compact: 1.4301 (304) |
| Degree of protection | Standard: IP66/67, type 4X enclosure Option: IP69 |
| Display/Operation | 4‐line backlit display available (no local operation) Configuration via web browser and operating tools possible |
| Outputs | 4‐20 mA HART (active) Pulse/frequency/switch output (passive) |
| Inputs | None |
| Digital communication | HART, PROFIBUS DP, Modbus RS485, EtherNet/IP, PROFINET |
| Power supply | DC 20 to 30 V |
| Hazardous area approvals | ATEX, IECEx, cCSAus, INMETRO, EAC |
| Product safety | CE, C-tick |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Verification: Heartbeat Technology complies with requirements for traceable verification according to ISO 9001:2008, chapter 7.6. a (TUV attestation) |
| Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval |
| Pressure approvals and certificates | PED, CRN |
| Material certificates | 3.1 material |
| Hygienic approvals and certificates | Sanitary approval: EHEDG, 3-A, liner and seals acc. to FDA, cGMP |
The Promag H sensor is particularly suitable for hygienic applications and meets the highest requirements in the food & beverage and life sciences industries. Combined with the compact transmitter, Promag H 300 offers flexible operation and convenient system integration: wiring on the same side of the instrument, remote display and improved connection options. Heartbeat Technology always ensures compliance and process safety.
Advantages
Flexible installation: a wide range of hygienic process connections
Energy-saving flow measurement: no pressure loss thanks to the absence of flow restrictors
Maintenance-free: no moving parts
Complete access to process and diagnostic information: a wide range of user-configurable input/output combinations and fieldbuses
Reduced complexity and variety: user-configurable input/output functions
Integrated verification: built-in Heartbeat Technology
Application areas
Bidirectional measuring principle unaffected by pressure, density, temperature and viscosity.
Suitable for demanding applications in the food & beverage and life sciences industries.
Instrument features
PFA liner
Stainless steel sensor housing (3-A approval, EHEDG tested)
Wetted-part materials resistant to CIP and SIP cleaning
Compact hygienic dual-compartment housing, IP69, with up to 3 inputs/outputs
Backlit display, touch control and WLAN access
Remote display unit available
E+H Product Model Configurator
Please enter the product model to configure
Product comparison
Please enter the product models to compare in the input fields below; up to three products can be compared
Technical documentation
Technical data
Documents / Manuals / Software
Accessories / Spare parts
Measuring principle video
Source:Endress+Hauserpublic information from the website
Case Studies
Municipal Wastewater Treatment — Wastewater Treatment Plant · Electromagnetic Flow Meter Application Case
Project Background
Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Electromagnetic Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Electromagnetic Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage — Food Production Line · Electromagnetic Flow Meter Application Case
Project Background
Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Electromagnetic Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Electromagnetic Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical — Reactors and Storage Tanks · Electromagnetic Flow Meter Application Case
Project Background
Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Electromagnetic Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Electromagnetic Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy — Power Plant Boiler and Turbine · Electromagnetic Flow Meter Application Case
Project Background
Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Electromagnetic Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Electromagnetic Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.