Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com
5L4C

电磁流量计

Configurable Models 12 models
The weight-optimized Promag L is suitable for applications in the water and wastewater industry. Due to its lap-joint flange concept, the flowmeter offers flexible and easy installation. Promag L 400 saves time and costs thanks to the broad functionality of its water- and wastewater-optimized transmitter. In addition, Heartbeat Technology ensures compliance and process safety at all times.
Compare

Liquids

Measuring Principle
Product headline std_productprofile_product_usp_8024.
std_productprofile_product_field_of_application_8025.
Sensor features std_productprofile_product_benefits_8026. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
std_productprofile_product_differentiating_tech_features_6649. std_productprofile_product_differentiating_tech_features_6650. std_successorproducts_product_differentiating_tech_features_35221_1509522592.
Transmitter features Safe operation – no need to open the device due to display with touch control, background lighting. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology.
Transmitter housing made of durable polycarbonate or aluminium. WLAN access. Integrated data logger: measured values monitoring.
Nominal diameter range Lap joint flange, lap joint flange, stamped plate: DN 25 to 300 (1 to 12")
Fixed flange: DN 350 to 2400 (14 to 90")
Wetted materials Liner: PTFE; Polyurethane; Hard rubber
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022)
Measured variables Volume flow, conductivity, mass flow
Max. measurement error Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s)
Measuring range 9 dm³/min to 162 000 m³/h (2.5 gal/min to 1030 Mgal/d)
Max. process pressure PN 16, Class 150
Medium temperature range Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +194 °F)
Ambient temperature range Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)
Sensor housing material DN 25 to 300 (1 to 12"): AlSi10Mg, coated
DN 350 to 2400 (14 to 90"): Carbon steel with protective varnish
Sensor connection housing: AlSi10Mg, coated
Transmitter housing material Polycarbonat; AlSi10Mg, coated
Degree of protection Compact version: IP66/67, type 4X enclosure
Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP68, type 6P enclosure
Transmitter remote version: IP66/67, Type 4X enclosure
Display/Operation 4‐line backlit display with touch control (operation from outside)
Configuration via local display, web browser and operating tools possible
Outputs 3 ouputs:
0‐20 mA/4‐20 mA HART (active)
Pulse/frequency/switch output (passive)
Pulse/frequency output (passive)
Switch output (passive)
Inputs Status input
Digital communication HART, PROFIBUS DP, EtherNet/IP, Modbus RS485
Power supply AC 100 to 240 V / AC/DC 24 V
Hazardous area approvals cCSAus
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Hygienic approvals and certificates Drinking water approval: ACS, KTW-BWGL, NSF 61, WRAS BS 6920

The versatile, lightweight Promag L sensor is the first choice for all standard applications in the water and wastewater industry. Its unique lap-joint flange process connection enables flexible, simple and economical installation. The Promag D 400 is equipped with a powerful transmitter for the water and wastewater industry, significantly reducing time and costs. In addition, Heartbeat Technology ensures compliance and process safety at all times.

 

Benefits

Reduced installation costs - unique slip-on flange design, flexible installation (DN<350/14")

Energy-saving flow measurement - cross-section identical to the pipe, no pressure loss

Maintenance-free - no moving parts

Operating safety - backlit display and touch control without opening the device

Localized operation without additional hardware and software, saving time - integrated web server

Integrated verification – Heartbeat Technology

 

Application areas

Bidirectional measuring principle not limited by pressure, density, temperature or viscosity

Standard applications in the water and wastewater industry

Instrument features

Weight reduced by up to 30%

Nominal diameter: DN 25 ~ 2400 (1 ~ 90")

Installation gap can be shortened to DVGW/ISO

Transmitter housing made of durable polycarbonate or aluminum

WLAN connection

Built-in data logger: measured value monitoring

 

 

 

E+H product model configurator

Please enter the product model to configure

Product comparison

Please enter the product models to be compared in the input boxes below; up to three products can be compared

 

   

Technical information

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

   

Measuring principle video

Source: public information from the Endress+Hauser website

Model Name
5L4C2H-AALHA0AQD210A+AK 5L4C2H-AALHA0AQD210A+AK
5L4C50-AALHA0AQD211A+AK 5L4C50-AALHA0AQD211A+AK
5L4C25-AALHA0AQD210A+AK 5L4C25-AALHA0AQD210A+AK
5L4C1Z-AALHA0AQD210A+AK 5L4C1Z-AALHA0AQD210A+AK
5L4C1H-AALHA0AQD210A+AK 5L4C1H-AALHA0AQD210A+AK
5L4C1F-AALHA0AQD210A+AK 5L4C1F-AALHA0AQD210A+AK
5L4C32-AALHA0AQD210A+AK 5L4C32-AALHA0AQD210A+AK
5L4C80-AALHA0AQD210A+AK 5L4C80-AALHA0AQD210A+AK
5L4C50-AALHA0AQD210A+AK 5L4C50-AALHA0AQD210A+AK
5L4C25-AALHM0AQD210A+AK 5L4C25-AALHM0AQD210A+AK
5L4C65-AALHA0AQD210A+AK 5L4C65-AALHA0AQD210A+AK
5L4C40-AALHA0AQD210A+AK 5L4C40-AALHA0AQD210A+AK
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Electromagnetic Flow Meter Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Electromagnetic Flow Meter.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Electromagnetic Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Electromagnetic Flow Meter Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Electromagnetic Flow Meter.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Electromagnetic Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Electromagnetic Flow Meter Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Electromagnetic Flow Meter.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Electromagnetic Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Electromagnetic Flow Meter Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Electromagnetic Flow Meter.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Electromagnetic Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.