Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

质量流量计 8F5B

质量流量计 8F5B

质量流量计 8F5B

Promass F has a long-standing reputation as a highly accurate sensor. Immune to fluctuating and harsh environments it is suited for the broadest range of applications. With its innovative remote transmitter Promass F 500 maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology ensures measurement reliability and enables extension of recalibration cycles.
Compare

Density

Measuring Principle Coriolis
Product Headline Flowmeter with premium accuracy and robustness, as remote version with up to 4 I/Os.
Highest measurement performance for liquids and gases under varying, demanding process conditions.
Sensor features Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Mass flow: measurement error ±0.05 % (PremiumCal). Medium temperature: –196 to 350 °C (–320 to 662 °F). Nominal diameter: DN 8 to 250 (³⁄₈ to 10").
Transmitter features Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter.
Nominal diameter range DN 8 to 250 (⅜ to 10")
Wetted materials Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022); 1.4301 (F304)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement error Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.25 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 2 200 000 kg/h (0 to 80 840 lb/min)
Max. process pressure PN 100, Class 600, 63K
Medium temperature range Standard: –50 to +150 °C (–58…+302 °F)
Option: –50 to +240 °C (–58…+464 °F)
High temperatur option: –50 to +350 °C (–58…+662 °F)
Option: –196 to +150 °C (–320 to +302 °F)
Ambient temperature range Standard: –40 to +60 °C (–40 to +140 °F)
Option: –60 to +60 °C (–76 to +140 °F)
Sensor housing material Standard: 1.4301 (304), corrosion resistant
Option: 1.4404 (316L)
Sensor connection housing (standard): AlSi10Mg, coated
Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L
Transmitter housing material AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat
Degree of protection Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP69.
Transmitter remote version: IP66/67, Type 4X enclosure
Display/Operation 4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Outputs 4 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output
Inputs Status input
4-20 mA input
Digital communication HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
Power supply DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)

Density/Concentration

Measuring Principle Coriolis
Product headline Flowmeter with premium accuracy and robustness, as remote version with up to 4 I/Os.
Highest measurement performance for liquids and gases under varying, demanding process conditions.
Sensor features Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Mass flow: measurement error ±0.05 % (PremiumCal). Medium temperature: –196 to 350 °C (–320 to 662 °F). Nominal diameter: DN 8 to 250 (³⁄₈ to 10").
Transmitter features Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter.
Nominal diameter range DN 8 to 250 (⅜ to 10")
Wetted materials Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022); 1.4301 (F304)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement error Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.25 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 2 200 000 kg/h (0 to 80 840 lb/min)
Max. process pressure PN 100, Class 600, 63K
Medium temperature range Standard: –50 to +150 °C (–58…+302 °F)
Option: –50 to +240 °C (–58…+464 °F)
High temperatur option: –50 to +350 °C (–58…+662 °F)
Option: –196 to +150 °C (–320 to +302 °F)
Ambient temperature range Standard: –40 to +60 °C (–40 to +140 °F)
Option: –60 to +60 °C (–76 to +140 °F)
Sensor housing material Standard: 1.4301 (304), corrosion resistant
Option: 1.4404 (316L)
Sensor connection housing (standard): AlSi10Mg, coated
Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L
Transmitter housing material AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat
Degree of protection Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP69.
Transmitter remote version: IP66/67, Type 4X enclosure
Display/Operation 4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Outputs 4 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output
Inputs Status input
4-20 mA input
Digital communication HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
Power supply DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC
Product safety CE, C-tick, EAC marking
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
MI-005 (Liquids other than water, Hydrocarbons, LPG, cryogenic liquids)
NTEP (Liquids other than water, LPG, cryogenic liquids)
MC (Liquids other than water, gases, cryogenic liquids)
MI-002, PTB
Marine approvals and certificates LR approval, DNV approval, ABS approval, BV approval, CCS approval
Pressure approvals and certificates PED, CRN, AD 2000
Material certificates 3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK
Hygienic approvals and certificates 3-A, EHEDG, cGMP

Gas

Measuring Principle Coriolis
Product headline Flowmeter with premium accuracy and robustness, as remote version with up to 4 I/Os.
Highest measurement performance for liquids and gases under varying, demanding process conditions.
Sensor features Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Mass flow: measurement error ±0.05 % (PremiumCal). Medium temperature: –196 to 350 °C (–320 to 662 °F). Nominal diameter: DN 8 to 250 (³⁄₈ to 10").
Transmitter features Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter.
Nominal diameter range DN 8 to 250 (⅜ to 10")
Wetted materials Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022); 1.4301 (F304)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement error Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.25 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 2 200 000 kg/h (0 to 80 840 lb/min)
Max. process pressure PN 100, Class 600, 63K
Medium temperature range Standard: –50 to +150 °C (–58 to +302 °F)
Option: –50 to +240 °C (–58 to +464 °F)
High temperatur option: –50 to +350 °C (–58 to +662 °F)
Option: –196 to +150 °C (–320 to +302 °F)
Ambient temperature range Standard: –40 to +60 °C (–40 to +140 °F)
Option: –60 to +60 °C (–76 to +140 °F)
Sensor housing material Standard: 1.4301 (304), corrosion resistant
Option: 1.4404 (316L)
Sensor connection housing (standard): AlSi10Mg, coated
Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L
Transmitter housing material AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat
Degree of protection Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP69.
Transmitter remote version: IP66/67, Type 4X enclosure
External WLAN antenna: IP67
Display/Operation 4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Outputs 4 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output
Inputs Status input
4-20 mA input
Digital communication HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
Power supply DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC
Product safety CE, C-tick, EAC marking
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
MI-005 (Liquids other than water, Hydrocarbons, LPG, cryogenic liquids)
NTEP (Liquids other than water, LPG, cryogenic liquids)
MC (Liquids other than water, gases, cryogenic liquids)
MI-002, PTB
Marine approvals and certificates LR approval, DNV approval, ABS approval, BV approval, CCS approval
Pressure approvals and certificates PED, CRN, AD 2000
Material certificates 3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK
Hygienic approvals and certificates 3-A, EHEDG, cGMP

Liquids

Measuring Principle Coriolis
Product headline Flowmeter with premium accuracy and robustness, as remote version with up to 4 I/Os.
Highest measurement performance for liquids and gases under varying, demanding process conditions.
Sensor features Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Mass flow: measurement error ±0.05 % (PremiumCal). Medium temperature: –196 to 350 °C (–320 to 662 °F). Nominal diameter: DN 8 to 250 (³⁄₈ to 10").
Transmitter features Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter.
Nominal diameter range DN 8 to 250 (⅜ to 10")
Wetted materials Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022); 1.4301 (F304)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement error Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.25 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 2 200 000 kg/h (0 to 80 840 lb/min)
Max. process pressure PN 100, Class 600, 63K
Medium temperature range Standard: –50 to +150 °C (–58…+302 °F)
Option: –50 to +240 °C (–58…+464 °F)
High temperatur option: –50 to +350 °C (–58…+662 °F)
Option: –196 to +150 °C (–320 to +302 °F)
Ambient temperature range Standard: –40 to +60 °C (–40 to +140 °F)
Option: –60 to +60 °C (–76 to +140 °F)
Sensor housing material Standard: 1.4301 (304), corrosion resistant
Option: 1.4404 (316L)
Sensor connection housing (standard): AlSi10Mg, coated
Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L
Transmitter housing material AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat
Degree of protection Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP69.
Transmitter remote version: IP66/67, Type 4X enclosure
Display/Operation 4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Outputs 4 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output
Inputs Status input
4-20 mA input
Digital communication HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
Power supply DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC
Product safety CE, C-tick, EAC marking
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
MI-005 (Liquids other than water, Hydrocarbons, LPG, cryogenic liquids)
NTEP (Liquids other than water, LPG, cryogenic liquids)
MC (Liquids other than water, gases, cryogenic liquids)
MI-002, PTB
Marine approvals and certificates LR approval, DNV approval, ABS approval, BV approval, CCS approval
Pressure approvals and certificates PED, CRN, AD 2000
Material certificates 3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK
Hygienic approvals and certificates 3-A, EHEDG, cGMP

Steam

Measuring Principle Coriolis
Product headline Flowmeter with premium accuracy and robustness, as remote version with up to 4 I/Os.
Highest measurement performance for liquids and gases under varying, demanding process conditions.
Sensor features Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Mass flow: measurement error ±0.05 % (PremiumCal). Medium temperature: –196 to 350 °C (–320 to 662 °F). Nominal diameter: DN 8 to 250 (³⁄₈ to 10").
Transmitter features Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter.
Nominal diameter range DN 8 to 250 (⅜ to 10")
Wetted materials Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022); 1.4301 (F304)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement error Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.25 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 2 200 000 kg/h (0 to 80 840 lb/min)
Max. process pressure PN 100, Class 600, 63K
Medium temperature range Standard: –50 to +150 °C (–58…+302 °F)
Option: –50 to +240 °C (–58…+464 °F)
High temperatur option: –50 to +350 °C (–58…+662 °F)
Option: –196 to +150 °C (–320 to +302 °F)
Ambient temperature range Standard: –40 to +60 °C (–40 to +140 °F)
Option: –60 to +60 °C (–76 to +140 °F)
Sensor housing material Standard: 1.4301 (304), corrosion resistant
Option: 1.4404 (316L)
Sensor connection housing (standard): AlSi10Mg, coated
Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L
Transmitter housing material AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat
Degree of protection Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP69.
Transmitter remote version: IP66/67, Type 4X enclosure
External WLAN antenna: IP67
Display/Operation 4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Outputs 4 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output
Inputs Status input
4-20 mA input
Digital communication HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
Power supply DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC
Product safety CE, C-tick, EAC marking
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
MI-005 (Liquids other than water, Hydrocarbons, LPG, cryogenic liquids)
NTEP (Liquids other than water, LPG, cryogenic liquids)
MC (Liquids other than water, gases, cryogenic liquids)
MI-002, PTB
Marine approvals and certificates LR approval, DNV approval, ABS approval, BV approval, CCS approval
Pressure approvals and certificates PED, CRN, AD 2000
Material certificates 3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK
Hygienic approvals and certificates cGMP

The Promass F is a proven high-precision sensor. Unaffected by fluctuations and harsh environments, it is widely applicable. Combined with the innovative remote transmitter, the Promass F 500 offers maximum installation flexibility and the highest operational safety even under demanding conditions. Heartbeat Technology ensures compliance at all times and guarantees process safety.

Benefits
Highest process safety: unaffected by fluctuations and demanding conditions
Fewer process measuring points: multivariable measurement (flow, density, temperature)
Space-saving installation: no inlet/outlet straight run requirement
Complete view of process and diagnostic information: various user-configurable input/output combinations and fieldbuses
Reduced complexity and diversity: user-configurable input/output functions
Integrated verification: built-in Heartbeat Technology

Applications
The measuring principle is unaffected by the physical properties of the fluid (e.g. viscosity and density).
Measurement of liquids and gases under changing, demanding conditions with the highest measuring performance.

Device features
Mass flow measurement error: ±0.05 % (PremiumCal)
Medium temperature: -196...350 °C (-320...662 °F)
Nominal diameter: DN 8...250 (3/8...10")
Remote version with up to 4 inputs/outputs
Backlit display, touch key operation and WLAN access
Sensor and transmitter connected by standard cable

 

E+H Product Model Configuration Tool

Please enter the product model to configure

Product comparison

Please enter the product models to compare in the fields below; up to three products can be compared

 

   

Technical documentation

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Mass Flow Meter Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Mass Flow Meter.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Mass Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Mass Flow Meter Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Mass Flow Meter.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Mass Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Mass Flow Meter Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Mass Flow Meter.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Mass Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Mass Flow Meter Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Mass Flow Meter.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Mass Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.