质量流量计 8I5B
Technical Data
CompareDensity
| Measuring Principle | Coriolis |
| Product Headline | Combines in-line viscosity and flow measurement with a transmitter remote version with up to 4 I/Os. Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment. |
| Sensor features | Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium. |
| Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
Density/Concentration
| Measuring Principle | Coriolis |
| Product headline | Combines in-line viscosity and flow measurement with a transmitter remote version with up to 4 I/Os. Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment. |
| Sensor features | Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium. |
| Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
| Nominal diameter range | DN 8 to 80 (⅜ to 3") |
| Wetted materials | Measuring tube: Titanium grade 9 Connection: Titanium grade 2 |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity |
| Max. measurement error | Mass flow (liquid): ±0.10 % Volume flow (liquid): ±0.10 % Mass flow (gas): ±0.50 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 180 000 kg/h (0 to 6600 lb/min) |
| Max. process pressure | PN 100, Class 600, 63K |
| Medium temperature range | –50 to +150 °C (–58 to +302 °F) |
| Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
| Sensor housing material | 1.4301 (304), corrosion resistant Sensor connection housing (standard): AlSi10Mg, coated Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L |
| Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat |
| Degree of protection | Sensor remote version (standard): IP66/67, type 4X enclosure Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure |
| Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible |
| Outputs | 4 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
| Inputs | Status input 4-20 mA input |
| Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
| Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
| Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
| Pressure approvals and certificates | PED, CRN |
| Material certificates | 3.1 material |
| Hygienic approvals and certificates | 3-A, EHEDG, cGMP |
Gas
| Measuring Principle | Coriolis |
| Product headline | Combines in-line viscosity and flow measurement with a transmitter remote version with up to 4 I/Os. Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment. |
| Sensor features | Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium. |
| Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
| Nominal diameter range | DN 8 to 80 (⅜ to 3") |
| Wetted materials | Measuring tube: Titanium grade 9 Connection: Titanium grade 2 |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity |
| Max. measurement error | Mass flow (liquid): ±0.10 % Volume flow (liquid): ±0.10 % Mass flow (gas): ±0.50 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 180 000 kg/h (0 to 6600 lb/min) |
| Max. process pressure | PN 100, Class 600, 63K |
| Medium temperature range | –50 to +150 °C (–58 to +302 °F) |
| Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
| Sensor housing material | 1.4301 (304), corrosion resistant Sensor connection housing (standard): AlSi10Mg, coated Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L |
| Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat |
| Degree of protection | Sensor remote version (standard): IP66/67, type 4X enclosure Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure" |
| Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible |
| Outputs | 4 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
| Inputs | Status input 4-20 mA input |
| Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
| Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
| Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
| Pressure approvals and certificates | PED, CRN |
| Material certificates | 3.1 material |
| Hygienic approvals and certificates | 3-A, EHEDG, cGMP |
Liquids
| Measuring Principle | Coriolis |
| Product headline | Combines in-line viscosity and flow measurement with a transmitter remote version with up to 4 I/Os. Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment. |
| Sensor features | Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium. |
| Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
| Nominal diameter range | DN 8 to 80 (⅜ to 3") |
| Wetted materials | Measuring tube: Titanium grade 9 Connection: Titanium grade 2 |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity |
| Max. measurement error | Mass flow (liquid): ±0.10 % Volume flow (liquid): ±0.10 % Mass flow (gas): ±0.50 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 180 000 kg/h (0 to 6600 lb/min) |
| Max. process pressure | PN 100, Class 600, 63K |
| Medium temperature range | –50 to +150 °C (–58 to +302 °F) |
| Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
| Sensor housing material | 1.4301 (304), corrosion resistant Sensor connection housing (standard): AlSi10Mg, coated Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L |
| Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat |
| Degree of protection | Sensor remote version (standard): IP66/67, type 4X enclosure Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure |
| Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible |
| Outputs | 4 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
| Inputs | Status input 4-20 mA input |
| Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
| Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
| Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
| Pressure approvals and certificates | PED, CRN |
| Material certificates | 3.1 material |
| Hygienic approvals and certificates | 3-A, EHEDG, cGMP |
Viscosity
| Measuring Principle | Coriolis |
| Product headline | Combines in-line viscosity and flow measurement with a transmitter remote version with up to 4 I/Os. Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment. |
| Sensor features | Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium. |
| Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
| Nominal diameter range | DN 8 to 80 (⅜ to 3") |
| Wetted materials | Measuring tube: Titanium grade 9 Connection: Titanium grade 2 |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity |
| Max. measurement error | Mass flow (liquid): ±0.10 % Volume flow (liquid): ±0.10 % Mass flow (gas): ±0.50 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 180 000 kg/h (0 to 6600 lb/min) |
| Max. process pressure | PN 100, Class 600, 63K |
| Medium temperature range | –50 to +150 °C (–58 to +302 °F) |
| Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
| Sensor housing material | 1.4301 (304), corrosion resistant Sensor connection housing (standard): AlSi10Mg, coated Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L |
| Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat |
| Degree of protection | Sensor remote version (standard): IP66/67, type 4X enclosure Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure |
| Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible |
| Outputs | 4 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
| Inputs | Status input 4-20 mA input |
| Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
| Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
| Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
| Pressure approvals and certificates | PED, CRN |
| Material certificates | 3.1 material |
| Hygienic approvals and certificates | 3-A, EHEDG, cGMP |
The Promass I single straight-tube design combines mass flow, density, temperature and online viscosity measurement effectively. Promass I 500 is equipped with an innovative remote transmitter that maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology always ensures compliance and process safety.
Advantages
Energy-saving: full-bore design ensures minimal pressure loss
Fewer process measuring points: multivariable measurement (flow, density, temperature)
Saves installation space: no upstream/downstream straight run requirements
Complete view of process and diagnostic information: various user-configurable input/output combinations and fieldbuses
Reduced complexity and diversity: user-configurable input/output functions
Integrated verification: built-in Heartbeat Technology
Application
The measuring principle is not affected by the physical properties of the fluid (e.g. viscosity and density).
Liquid and gas measurement in applications with low pressure loss requirements and sensitive fluids.
Device features
Self-draining single straight-tube measuring system
TMB technology
Measuring tube material: titanium
Remote version with up to 4 inputs/outputs
Backlit display, touch key control and WLAN access
Sensor and transmitter connected via standard cable
E+H Product Configurator
Please enter the product model to configure
Product comparison
Please enter the product models to compare in the boxes below (max. three products)
Technical documentation
Technical data
Documents/Manuals/Software
Accessories/Spare parts
Source:Endress+Hauserwebsite public information
Case Studies
Municipal Wastewater Treatment — Wastewater Treatment Plant · Mass Flow Meter Application Case
Project Background
Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Mass Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Mass Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage — Food Production Line · Mass Flow Meter Application Case
Project Background
Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Mass Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Mass Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical — Reactors and Storage Tanks · Mass Flow Meter Application Case
Project Background
Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Mass Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Mass Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy — Power Plant Boiler and Turbine · Mass Flow Meter Application Case
Project Background
Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Mass Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Mass Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.