300 科里奥利质量流量计
Technical Data
CompareDensity/Concentration
| Measuring Principle | Coriolis |
| Product headline | Robust high-pressure flowmeter with a compact, easily accessible transmitter. For premium accuracy at highest process pressures, fully suitable for offshore conditions. |
| Sensor features | Maximum safety – highest resistance to stress corrosion cracking. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Measuring tube in 25Cr Duplex, 1.4410 (UNS S32750). Process pressure up to PN 250 (Class 1500). Nominal diameter: DN 80 to 250 (3 to 10"). |
| Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available. |
| Nominal diameter range | DN 80 to 250 (3 to 10") |
| Wetted materials | Measuring tube: 25Cr duplex (Super Duplex), 1.4410 (UNS S32750) Connection: 25Cr duplex (Super Duplex), 1.4410 (F53) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration |
| Max. measurement error | Mass flow (liquid): ±0.10 % (standard), 0.05 % (option) Volume flow (liquid): ±0.10 % Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 2 200 000 kg/h (0 to 80 850 lb/min) |
| Max. process pressure | PN 250, Class 1500 |
| Medium temperature range | –40 to +205 °C (–40 to +401 °F) |
| Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
| Sensor housing material | 1.4404 (316L), highest corrosion resistance |
| Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L |
| Degree of protection | IP66/67, type 4X enclosure |
| Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available |
| Outputs | 3 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
| Inputs | Status input 4-20 mA input |
| Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
| Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
| Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) MI-005 Liquids other than water (Hydrocarbons), Cryogenic Liquids, LPG OIML R117 Liquids other than water, Cryogenic Liquids, LPG MI-002, PTB |
| Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval, CCS approval |
| Pressure approvals and certificates | PED, CRN, AD 2000 |
| Material certificates | 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK" |
Gas
| Measuring Principle | Coriolis |
| Product headline | Robust high-pressure flowmeter with a compact, easily accessible transmitter. For premium accuracy at highest process pressures, fully suitable for offshore conditions. |
| Sensor features | Maximum safety – highest resistance to stress corrosion cracking. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Measuring tube in 25Cr Duplex, 1.4410 (UNS S32750). Process pressure up to PN 250 (Class 1500). Nominal diameter: DN 80 to 250 (3 to 10"). |
| Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available. |
| Nominal diameter range | DN 80 to 250 (3 to 10") |
| Wetted materials | Measuring tube: 25Cr duplex (Super Duplex), 1.4410 (UNS S32750) Connection: 25Cr duplex (Super Duplex), 1.4410 (F53) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration |
| Max. measurement error | Mass flow (liquid): ±0.10 % (standard), 0.05 % (option) Volume flow (liquid): ±0.10 % Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 2 200 000 kg/h (0 to 80 850 lb/min) |
| Max. process pressure | PN 250, Class 1500 |
| Medium temperature range | –46 to +205 °C (–46 to +401 °F) |
| Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
| Sensor housing material | 1.4404 (316L), highest corrosion resistance |
| Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L |
| Degree of protection | IP66/67, type 4X enclosure |
| Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available |
| Outputs | 3 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
| Inputs | Status input 4-20 mA input |
| Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
| Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
| Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) MI-005 Liquids other than water (Hydrocarbons), Cryogenic Liquids, LPG OIML R117 Liquids other than water, Cryogenic Liquids, LPG MI-002, PTB |
| Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval, CCS approval |
| Pressure approvals and certificates | PED, CRN, AD 2000 |
| Material certificates | 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK |
Liquids
| Measuring Principle | Coriolis |
| Product headline | Robust high-pressure flowmeter with a compact, easily accessible transmitter. For premium accuracy at highest process pressures, fully suitable for offshore conditions. |
| Sensor features | Maximum safety – highest resistance to stress corrosion cracking. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Measuring tube in 25Cr Duplex, 1.4410 (UNS S32750). Process pressure up to PN 250 (Class 1500). Nominal diameter: DN 80 to 250 (3 to 10"). |
| Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available. |
| Nominal diameter range | DN 80 to 250 (3 to 10") |
| Wetted materials | Measuring tube: 25Cr duplex (Super Duplex), 1.4410 (UNS S32750) Connection: 25Cr duplex (Super Duplex), 1.4410 (F53) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration |
| Max. measurement error | Mass flow (liquid): ±0.10 % (standard), 0.05 % (option) Volume flow (liquid): ±0.10 % Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 2 200 000 kg/h (0 to 80 850 lb/min) |
| Max. process pressure | PN 250, Class 1500 |
| Medium temperature range | –46 to +205 °C (–46 to +401 °F) |
| Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
| Sensor housing material | 1.4404 (316L), highest corrosion resistance |
| Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L |
| Degree of protection | IP66/67, type 4X enclosure |
| Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available |
| Outputs | 3 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
| Inputs | Status input 4-20 mA input |
| Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
| Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
| Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) MI-005 Liquids other than water (Hydrocarbons), Cryogenic Liquids, LPG OIML R117 Liquids other than water, Cryogenic Liquids, LPG MI-002, PTB |
| Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval, CCS approval |
| Pressure approvals and certificates | PED, CRN, AD 2000 |
| Material certificates | 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK" |
Steam
| Measuring Principle | Coriolis |
| Product headline | Robust high-pressure flowmeter with a compact, easily accessible transmitter. For premium accuracy at highest process pressures, fully suitable for offshore conditions. |
| Sensor features | Maximum safety – highest resistance to stress corrosion cracking. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Measuring tube in 25Cr Duplex, 1.4410 (UNS S32750). Process pressure up to PN 250 (Class 1500). Nominal diameter: DN 80 to 250 (3 to 10"). |
| Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available. |
| Nominal diameter range | DN 80 to 150 (3 to 6") |
| Wetted materials | Measuring tube: 25Cr duplex (Super Duplex), 1.4410 (UNS S32750) Connection: 25Cr duplex (Super Duplex), 1.4410 (F53) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration |
| Max. measurement error | Mass flow (liquid): ±0.10 % (standard), 0.05 % (option) Volume flow (liquid): ±0.10 % Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 800 000 kg/h (0 to 29 400 lb/min) |
| Max. process pressure | PN 250, Class 1500 |
| Medium temperature range | –46 to +205 °C (–46 to +401 °F) |
| Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
| Sensor housing material | 1.4404 (316L), highest corrosion resistance |
| Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L |
| Degree of protection | IP66/67, type 4X enclosure |
| Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available |
| Outputs | 3 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
| Inputs | Status input 4-20 mA input |
| Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
| Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
| Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) MI-005 Liquids other than water (Hydrocarbons), Cryogenic Liquids, LPG OIML R117 Liquids other than water, Cryogenic Liquids, LPG MI-002, PTB |
| Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval, CCS approval |
| Pressure approvals and certificates | PED, CRN, AD 2000 |
| Material certificates | 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK |
Proline Promass O 300
Coriolis mass flowmeter
Robust high-pressure flowmeter with compact, easily accessible transmitter
Advantages
Highest safety – maximum resistance to stress corrosion cracking
Fewer process measuring points – multivariable measurement (flow, density, temperature)
Space-saving installation – no inlet/outlet runs required
Full access to process and diagnostic information – numerous freely combinable I/Os and Ethernet
Reduced complexity and diversity – freely configurable I/O functionality
Integrated verification – Heartbeat Technology
Field of application
Promass O is designed for high-precision analysis of liquids and gases under the highest process pressures in the oil and gas industry. The sensor is fully suitable for offshore conditions and resistant to stress corrosion cracking. The Promass O 300 features a compact transmitter offering a high degree of flexibility in operation and system integration: access from one side, remote display and improved connection options. Heartbeat Technology enables safe processes.
The measuring principle is unaffected by fluid properties such as viscosity or density
High precision at the highest process pressures, fully suitable for offshore conditions
Device properties
25Cr duplex steel measuring tube, 1.4410 (UNS S32750)
Process pressure up to PN 250 (Class 1500)
Nominal diameter: DN 80 to 250 (3 to 10”)
Compact two-compartment housing with up to 3 I/Os
Backlit display with touch control and WLAN access
Remote display available
E+H product configurator
Please enter the product order code to configure
Product comparison
Please enter the order codes of the products you wish to compare in the fields below (up to three products)
Technical documentation
Technical data
Documents/Manuals/Software
Accessories/Spare parts
Source:Endress+Hauserpublic information from the website
Case Studies
Municipal Wastewater Treatment — Wastewater Treatment Plant · Mass Flow Meter Application Case
Project Background
Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Mass Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Mass Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage — Food Production Line · Mass Flow Meter Application Case
Project Background
Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Mass Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Mass Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical — Reactors and Storage Tanks · Mass Flow Meter Application Case
Project Background
Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Mass Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Mass Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy — Power Plant Boiler and Turbine · Mass Flow Meter Application Case
Project Background
Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Mass Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Mass Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.