500 科里奥利质量流量计
Technical Data
CompareDensity
| Measuring Principle | Coriolis |
| Product Headline | Easy-to-clean device with self-drainable single-tube system, as remote version with up to 4 I/Os. Dedicated to applications requiring optimal cleanability under hygienic conditions. |
Density/Concentration
| Measuring Principle | Coriolis |
| Product headline | Easy-to-clean device with self-drainable single-tube system, as remote version with up to 4 I/Os. Dedicated to applications requiring optimal cleanability under hygienic conditions. |
| Sensor features | Increased process safety – easily cleanable and fully self-drainable tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Large range of hygienic process connections. 3-A and EHEDG conform. Fast recovery from CIP/SIP. |
| Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os; hygienic sensor connection housing with IP69. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
| Nominal diameter range | DN 8 to 50 (⅜ to 2") |
| Wetted materials | Measuring tube: 1.4435 (316L) Connection: 1.4435 (316L); 1.4404 (316/316L) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
| Max. measurement error | Mass flow (liquid): ±0.10 % Volume flow (liquid): ±0.10 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 70 000 kg/h (0 to 2570 lb/min) |
| Max. process pressure | PN 40, Class 150, 20K |
| Medium temperature range | –50 to +150 °C (–58 to +302 °F) |
| Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
| Sensor housing material | 1.4301 (304), corrosion resistant Sensor connection housing (standard): AlSi10Mg, coated Sensor connection housing (option): 1.4301 (304); 1.4404 (316L) |
| Transmitter housing material | AlSi10Mg, coated; Polycarbonat |
| Degree of protection | Sensor remote version (standard): IP66/67, type 4X enclosure Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure |
| Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible |
| Outputs | 4 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
| Inputs | Status input 4-20 mA input |
| Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
| Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
| Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
| Pressure approvals and certificates | PED, CRN |
| Material certificates | 3.1 material |
| Hygienic approvals and certificates | 3-A, EHEDG, cGMP |
Gas
| Measuring Principle | Coriolis |
| Product headline | Easy-to-clean device with self-drainable single-tube system, as remote version with up to 4 I/Os. Dedicated to applications requiring optimal cleanability under hygienic conditions. |
| Sensor features | Increased process safety – easily cleanable and fully self-drainable tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Large range of hygienic process connections. 3-A and EHEDG conform. Fast recovery from CIP/SIP. |
| Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os; hygienic sensor connection housing with IP69. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
| Hygienic approvals and certificates | cGMP |
Liquids
| Measuring Principle | Coriolis |
| Product headline | Easy-to-clean device with self-drainable single-tube system, as remote version with up to 4 I/Os. Dedicated to applications requiring optimal cleanability under hygienic conditions. |
| Sensor features | Increased process safety – easily cleanable and fully self-drainable tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Large range of hygienic process connections. 3-A and EHEDG conform. Fast recovery from CIP/SIP. |
| Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os; hygienic sensor connection housing with IP69. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
| Nominal diameter range | DN 8 to 50 (⅜ to 2") |
| Wetted materials | Measuring tube: 1.4435 (316L) Connection: 1.4435 (316L); 1.4404 (316/316L) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
| Max. measurement error | Mass flow (liquid): ±0.10 % Volume flow (liquid): ±0.10 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 70 000 kg/h (0 to 2570 lb/min) |
| Max. process pressure | PN 40, Class 150, 20K |
| Medium temperature range | –50 to +150 °C (–58 to +302 °F) |
| Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
| Sensor housing material | 1.4301 (304), corrosion resistant Sensor connection housing (standard): AlSi10Mg, coated Sensor connection housing (option): 1.4301 (304); 1.4404 (316L) |
| Transmitter housing material | AlSi10Mg, coated; Polycarbonat |
| Degree of protection | Sensor remote version (standard): IP66/67, type 4X enclosure Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure |
| Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible |
| Outputs | 4 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
| Inputs | Status input 4-20 mA input |
| Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
| Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
| Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
| Pressure approvals and certificates | PED, CRN |
| Material certificates | 3.1 material |
| Hygienic approvals and certificates | 3-A, EHEDG, cGMP |
Proline Promass S 500
Coriolis mass flowmeter
Easy-to-clean device with self-draining single-tube system, as a remote version with up to 4 I/Os
Advantages
Increased process safety – easy-to-clean and fully self-draining tube design
Fewer process measuring points – multivariable measurement (flow, density, temperature)
Space-saving installation – no inlet/outlet runs required
Full access to process and diagnostic information – numerous freely combinable I/Os and Ethernet
Reduced complexity and diversity – freely configurable I/O functionality
Integrated verification – Heartbeat Technology
Field of application
The Promass S leads the way in hygienic design and is dedicated to food and beverage industry applications that require optimum cleanability. The self-draining single-tube system ensures gentle handling of liquids. The Promass S 500 features an innovative remote transmitter that maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology always ensures process safety.
The measuring principle is unaffected by fluid properties such as viscosity or density
Dedicated to applications that require optimum cleanability under hygienic conditions
Device properties
Various hygienic process connections
Complies with 3-A and EHEDG standards
Fast recovery from CIP/SIP
Remote version with up to 4 I/Os; hygienic sensor connection housing with IP69 degree of protection
Backlit display with touch control and WLAN access
Standard cable between sensor and transmitter
E+H product configurator
Please enter the product order code to configure
Product comparison
Please enter the order codes of the products you wish to compare in the fields below (up to three products)
Technical documentation
Technical data
Documents/Manuals/Software
Accessories/Spare parts
Source:Endress+Hauserpublic information from the website
Case Studies
Municipal Wastewater Treatment — Wastewater Treatment Plant · Mass Flow Meter Application Case
Project Background
Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Mass Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Mass Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage — Food Production Line · Mass Flow Meter Application Case
Project Background
Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Mass Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Mass Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical — Reactors and Storage Tanks · Mass Flow Meter Application Case
Project Background
Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Mass Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Mass Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy — Power Plant Boiler and Turbine · Mass Flow Meter Application Case
Project Background
Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Mass Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Mass Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.