CA80PH 正磷酸盐分析仪

CA80PH 正磷酸盐分析仪

Liquiline System CA80PH

Liquiline System CA80PH offers online orthophosphate measurement for precise dosing of precipitants in wastewater treatment. As all Liquiline System analyzers, it enables plug & play of up to 4 Memosens sensors - minimizing the installation effort. Automatic calibration and cleaning and the low consumption of reagents save you operating costs. Advanced diagnostics with remote access ensure process safety and support you in providing process documentation to the authorities.
Compare

Analyser

Measuring Principle Colorimetric
Characteristic Process analyzer for orthophosphate in aqueous solutions
Comply with standard colorimetric measuring principle, molybdenum blue method, following DIN EN 1189 or molybdate vanadate method
Size Housing (open version):
793 x 530 x 417 mm
31.22 x 20.87 x 16.42 in
Housing (closed version):
793 x 530 x 463 mm
31.22 x 20.87 x 18.23 in
Housing with base:
1723 x 530 x 463 mm
67.83 x 20.87 x 18.23 in
Design Open design, cabinet and stand housing
High-Performance plastic ASA-PC, additional stand coated steel
Process temperature 4 to 40 °C (39.2 to 104 °F)
Ambient temperature 5 to 40 °C (41 to 104 °F)
Outdoor version: - 20 to 40 °C (-4 to 104 °F)
Process pressure At atmospheric pressure, < 0.2 bar
Sample flow rate Min. 5 ml/min (0.17 fl.oz/min)
Consistency of the sample Suspended solids content
Turbitity < 50 NTU, aqueous, homogenized
Application Monitoring and optimization of the cleaning capacity of municipal and industrial waste water treatment plants
Power supply 100 to 120 VAC / 200 to 240 VAC ± 10%
24 VDC ± 10%
50 ± 1 or 60 ± 1,2 Hz
Output / communication 2x 0/4 to 20 mA
Modbus RS485/TCP
Input 1 or 2 measuring channel
1 to 4 digital sensor inputs for sensors with Memosens protocol (optional)
Measuring range 0 to 2.5 mg/l PO4-P (blue method)
0.05 to 10 mg/l PO4-P (blue method)
0.05 to 10 mg/l with dilution function to maximum 2.5 to 500 mg/l PO4-P (blue method)
0.5 to 20 mg/l PO4-P (yellow method)
0.5 to 50 mg/l PO4-P (yellow method)
0.5 to 50 mg/l with dilution function to maximum 10 to 1000 mg/l PO4-P (yellow method)
Consumables Reagents and standard solutions CY80H as well as cleaner CY800 (blue method) are necessary for the operation
Regular maintenance is done with the parts of the maintenance kit CAV800

Liquiline System CA80PH provides reliable data support for the precision of precipitant dosing in wastewater treatment plants through online orthophosphate measurement. All Liquiline System analyzers can connect up to 4 plug-and-play Memosens sensors - minimizing installation costs. Automatic calibration and cleaning as well as low reagent consumption save operating costs. Advanced diagnostics with remote access ensure process safety and provide users with process documentation for convenient process management.

 

Benefits

Convenient commissioning, plug-and-play thanks to Memosens technology and a user-friendly interface

Easy functional upgrade - even to a complete measuring station - by simply adding the corresponding modules and connecting the appropriate Memosens sensors

Advanced diagnostics with remote access improve process safety

Automatic calibration, automatic cleaning and extended reagent shelf life via a cooling unit effectively reduce operating costs

Two standardized measuring methods covering all applications: molybdenum blue and molybdenum vanadate methods

 

Application

Liquiline System CA80PH helps you optimize the purification capacity of wastewater treatment plants. It can monitor and control:

 

Precipitant dosing in aeration tanks

Wastewater treatment plant outlet

In industrial applications, Liquiline System CA80PH is used for cooling water circuit monitoring.

 

 

E+H Product Configurator

Please enter the product model to configure

Product Comparison

Please enter the product models to compare in the fields below. Up to three products can be compared

 

   

Technical Documentation

   

Technical Specifications

 

 

Documents/Manuals/Software

 

 

Accessories/Spare Parts

 

A

Source:Endress+Hauserwebsite public information

Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · EH-ONLINE Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of EH-ONLINE.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable EH-ONLINE for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · EH-ONLINE Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of EH-ONLINE.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable EH-ONLINE for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · EH-ONLINE Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of EH-ONLINE.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable EH-ONLINE for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · EH-ONLINE Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of EH-ONLINE.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable EH-ONLINE for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.