Technical Data
CompareAnalyser
| Measuring Principle | |
| Characteristic | Sample Preparation |
| Size | 370 x 200 x 70 mm 14.43 x 7.8 x 2.73 inch |
| Design | Housing CAT 411 POM Fastening screws Stainless steelSeals Perbunan®Filter membrane PTFE |
| Process temperature | 5 to 50 °C (41 to 122 °F) |
| Ambient temperature | 5 to 50 °C (41 to 122 °F) |
| Process pressure | 0.2 to 1 bar (3 to 15 psi) |
| Consistency of the sample | to max. 8 g/l TS |
| Specials | Sample preparation made of pressure pipe without additional pump possible, otherwise a feed pump is needed |
| Application | Water, Wastewater, Processwater |
| Consumables | Filter membranes necessary |
Stamoclean CAT411 to provide sterile microfiltration filtrate to the pipeline under pressure. Its self-cleaning interception filtration unit can avoid clogging of filtrate and improve process safety. With minimum dead volume, it can quickly respond to process changes and shorten the response time of downstream measurement equipment. Stamoclean CAT 411 can be easily integrated into existing processes.
advantage
Sturdy structure, high operational safety
Aseptic microfiltration unit
Easy installation
Low dead time to ensure fast response of downstream measuring devices
Self-cleaning function reduces the cost of use
Application areas
Stamoclean CAT411 is a sample pretreatment unit with self-cleaning function:
municipal sewage treatment plant:
-return sludge
-Excess sludge
-secondary sedimentation tank
industrial sewage treatment plant:
-return sludge
-Excess sludge
-secondary sedimentation tank
Installation of process pressure piping
technical parameters
Documentation/Manuals/Software
Accessories/Spare Parts
Source:Endress Hauserwebsite public information
Case Studies
Municipal Wastewater Treatment — Wastewater Treatment Plant · EH-ONLINE Application Case
Project Background
Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of EH-ONLINE.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable EH-ONLINE for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage — Food Production Line · EH-ONLINE Application Case
Project Background
Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of EH-ONLINE.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable EH-ONLINE for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical — Reactors and Storage Tanks · EH-ONLINE Application Case
Project Background
Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of EH-ONLINE.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable EH-ONLINE for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy — Power Plant Boiler and Turbine · EH-ONLINE Application Case
Project Background
Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of EH-ONLINE.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable EH-ONLINE for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Related Products
Endress+Hauser总氮分析仪
Endress+HauserLiquiline System CA80COD
Endress+HauserLiquiline System CA80AM
Endress+HauserViomax CAS51D
Endress+HauserISEmax sensor CAS40D
Endress+HauserLiquiline System CA80TP
Endress+HauserLiquiline System CA80HA
Endress+Hauser