Technical Data
CompareAnalyser
| Measuring Principle | UV photometric |
| Characteristic | Flow cell for extractive measurement with UV photometer Viomax CAS51D (measurement of Nitrate or SAC254) and UV/VIS spectrometer Memosens Wave CAS80E (measurement of TOCeq, CODeq, BODeq, SAC254, TU/TSS, Nitrate, APHA/Hazen color) |
| Design | 40 mm |
| Process temperature | 0 to 50°C 32 to 122 °F |
| Ambient temperature | 0 to 60°C 32 to 140 °F |
| Process pressure | 0 to 6 bar abs. 0 to 87 psi |
| Sample flow rate | 0.1 to 10 l/h |
| Application | Flow cell for monitoring of wastewater outlet drinking water, process water and surface water |
Concentration
| Measuring Principle | Absorption |
| Application | Flow cell for monitoring of wastewater outlet drinking water, process water and surface water |
| Characteristic | Flow cell for extractive measurement with UV photometer Viomax CAS51D (measurement of Nitrate or SAC254) and UV/VIS spectrometer Memosens Wave CAS80E (measurement of TOCeq, CODeq, BODeq, SAC254, TU/TSS, Nitrate, APHA/Hazen color) |
| Design | 40 mm |
| Material | Body: POM-C, Nut: Stainless Steel, O-rings: EPDM |
| Process temperature | 0 to 50°C 32 to 122 °F |
| Process pressure | 0 to 6 bar abs. 0 to 87 psi |
| Connection | G1/4 (optional DN6/8) |
Turbidity
| Measuring Principle | Absorption |
| Application | Flow cell for monitoring of wastewater outlet drinking water, process water and surface water |
| Characteristic | Flow cell for extractive measurement with UV photometer Viomax CAS51D (measurement of Nitrate or SAC254) and UV/VIS spectrometer Memosens Wave CAS80E (measurement of TOCeq, CODeq, BODeq, SAC254, TU/TSS, Nitrate, APHA/Hazen color) |
| Design | 40 mm |
| Material | Body: POM-C, Nut: Stainless Steel, O-rings: EPDM |
| Dimension | with cleaning adapter: 147 x 128.8 mm 5.79 x 5.07 in |
| Process temperature | 0 to 50°C 32 to 122 °F |
| Process pressure | 0 to 6 bar abs. 0 to 87 psi |
| Connection | G1/4 (optional DN6/8) |
Flow assembly CAV01
Flow assembly for optical, chemical-free concentration measurement in drinking water and process water
Advantages
Extended maintenance intervals thanks to optimized automatic pressure cleaning.
Minimal water loss: precise measurement at low sample flow rates
Robust design: suitable for process pressures up to 6 bar (87 psi) and temperatures up to 50 °C (122 °F)
Fully compatible with all optical path lengths of the Memosens Wave CAS80E and Viomax CAS51D
Pre-mounted wall bracket and fixed sensor orientation for simple installation
Tool-free disassembly for fast maintenance
Field of application
With the Memosens Wave CAS80E spectrometer or the Viomax CAS51D nitrate/SAC sensor installed, the CAV01 can monitor up to 5 parameters. Thanks to the fast response time of the sensor and continuous measurement, unexpected events in the process can be identified at an early stage. The integrated pressure cleaning function of the assembly ensures extended maintenance intervals. The CAV01 enables precise measurement at low flow rates of 0.1 to 10 l/h, thus minimizing water loss.
The CAV01 flow assembly is suitable for bypass measurement of various parameters such as SAC54, COD, BOD, TOC, turbidity, TSS, APHA/Hazen and nitrate in the following applications:
Drinking water treatment and distribution network monitoring
Quality control at all measuring points in drinking water production
Raw water monitoring
Process water treatment and monitoring
Water reuse monitoring
Cooling water and condensate
Municipal and industrial wastewater monitoring
Control of aeration basins
E+H product configurator
Please enter the product order code to configure
Product comparison
Please enter the order codes of the products you wish to compare in the fields below (up to three products)
Technical documentation
Technical data
Documents/Manuals/Software
Accessories/Spare parts
Source:Endress+Hauserpublic information from the website
Case Studies
Municipal Wastewater Treatment — Wastewater Treatment Plant · Brackets Application Case
Project Background
Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Brackets.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Brackets for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage — Food Production Line · Brackets Application Case
Project Background
Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Brackets.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Brackets for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical — Reactors and Storage Tanks · Brackets Application Case
Project Background
Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Brackets.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Brackets for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy — Power Plant Boiler and Turbine · Brackets Application Case
Project Background
Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Brackets.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Brackets for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Related Products
Endress+HauserEcofit CPA640, Adapterset
Endress+HauserFlowfit W CPA250
Endress+HauserCleanfit W CPA450
Endress+HauserFlowfit P CPA240
Endress+HauserCleanfit CPA871
Endress+HauserFLEXDIP CYA112
Endress+HauserDipfit W CPA111
Endress+Hauser