Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

Flow type installation bracket for CCA151 chlorine dioxide sensor

Flow type installation bracket for CCA151 chlorine dioxide sensor

Flowfit CCA151

Configurable Models 1 models
Simple installation bracket, suitable for drinking water and process water applications
Compare

Disinfection

Measuring Principle
Application Drinking water
Utilities of all industries
For low sample flow
Characteristic Flow through assembly for one disinfection sensor
Design Flow assembly with direct inflow to the membran
Material Plexiglas (PMMA)
Dimension 85 mm x 85 mm x 220 mm
(3.35 inch x 3.35 inch x 8.64 inch)
Process temperature Max. 60 °C
(Max. 140 °F)
Process pressure Max. 4 bar relative
(Max. 58 psi relative)

The Flowfit CCA151 assembly is used to install disinfectant sensors that do not require pH compensation, such as chlorine dioxide sensors, and is easy to use. The sensor is installed in an acrylic glass rod, allowing high-precision measurement as long as the medium flow rate is at least 5 l/h (1.32 gph). Precise control of the disinfection process therefore requires only minimal water loss. The Flowfit CCA151 offers flexible installation with panel, wall and pipe mounting options, allowing the disinfectant sensor to be installed at the most suitable location for optimal measurement results.

Benefits
Minimum water loss: when the sensor is installed in the Flowfit CCA151, high-precision chlorine dioxide measurement is possible as long as the medium flow rate is at least 5 l/h (1.32 gph). Only a very small amount of water is consumed.
Reliable measurement: flexible installation allows the sensor to be positioned precisely where the chlorine dioxide concentration needs to be accurately determined.
Cost-effective upgrade of your measuring point: identical external dimensions to the CCA250, making replacement simple.

Applications
The CCA151 flow assembly has no pH compensation function and is used to install disinfectant sensors, e.g. chlorine dioxide sensors, and is suitable for:
Drinking water
Utilities in various industries
Low-flow applications

 

E+H Product Model Configuration Tool

Please enter the product model to configure

Product comparison

Please enter the product models to compare in the fields below; up to three products can be compared

 

   

Technical documentation

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

A

Source: Endress+Hauserpublic information from the website

Model Name
CCA151-AAB1 二氧化氯传感器的流通式安装支架
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Disinfection Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Disinfection.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Disinfection for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Disinfection Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Disinfection.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Disinfection for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Disinfection Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Disinfection.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Disinfection for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Disinfection Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Disinfection.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Disinfection for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.