CCS50 Analog Chlorine Dioxide Sensor

CCS50 Analog Chlorine Dioxide Sensor

Analog chlorine dioxide sensor CCS50

Configurable Models 20 models
Sensors are suitable for water, process water, and utilities in various industries
Compare

Disinfection

Measuring Principle Chlorine dioxide
Application Guarantees reliable disinfection in drinking water
Prevents the growth of biofilms and pathogens in cooling water
Ensures food quality
Ensures the absence or presence of chlorine dioxide in Utilities
Characteristic Amperometric measurement of dissolved chlorine dioxide
Measuring range Trace: 0 to 5 mg/l ClO2
Standard: 0 to 20 mg/l ClO2
Measuring method Closed, membrane covered measuring cell
Reduction of chlordioxide at the cathode
Design Closed amperometric 2-electrode measuring cell with PVDF membrane
Material Sensor shaft: POM
Membrane: PVDF
Membrane cap: PVDF
Sealing ring: FKM
Dimension Diameter: 25 mm (0.98 inch)
Length: 126 mm (4.96 inch)
Process temperature 0 to 55 °C (32 to 130°F), non-freezing
Process pressure Max.1 bar (max. 14.5 psi)
Temperature sensor 10k NTC
Connection Analog with fixed cable

The CCS50 chlorine dioxide sensor is robust and low-maintenance. It quickly provides stable measured values for water, process water and utility applications. The sensor ensures an efficient disinfection process even at minimum flow, achieving the highest water quality and safety, avoiding chlorine dioxide overdosing or ensuring that beverage plants and reverse osmosis processes are free of ClO2. The CCS50 analog chlorine dioxide sensor provides continuous measured values at the measuring point.

Benefits
Fast response (t90 < 15 seconds) with highly accurate display of the process status, enabling timely action in response to process changes and efficient process control.
Higher process safety: precise, long-term stable measurement enables permanent process monitoring and flexible adjustment of the disinfectant concentration as required.
Flexible installation: the sensor can be installed in the CCA151 and CCA250 flow-through holders or in an immersion holder. Measurement is independent of flow at flow rates above 5 l/h (CCA151), 30 l/h (CCA250) or 15 cm/s (immersion).
The fluorescence sensor is low-maintenance and significantly reduces the operating costs of the measuring point compared with colorimetric measuring systems.
Used together with the Liquisys chlorine transmitter, it provides continuous analog chlorine dioxide measured values at the measuring point.

Applications
The CCS50 chlorine dioxide sensor meets the requirements of skid manufacturers and end users. It reliably measures:
Drinking water, ensuring complete disinfection
Cooling systems or cooling towers, preventing pathogen growth
Wash water for bagged vegetables and salads, ensuring food quality
Beverage plants, ensuring the absence of chlorine dioxide

 

E+H Product Model Configuration Tool

Please enter the product model to configure

Product comparison

Please enter the product models to compare in the fields below; up to three products can be compared

 

   

Technical documentation

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

A

Source: Endress+Hauserpublic information from the website

Model Name
CCS50-AA11BF03 模拟式二氧化氯传感器
CCS50-AA11AD03 模拟式二氧化氯传感器
CCS50-AA11BF01 模拟式二氧化氯传感器
CCS50-AA11AD01 模拟式二氧化氯传感器
CCS50-AA11AD01+NB 模拟式二氧化氯传感器
CCS50-AA11AD01+NA 模拟式二氧化氯传感器
CCS50-GR11AD03+NC 模拟式二氧化氯传感器
CCS50-AA11AD01+ND 模拟式二氧化氯传感器
CCS50-GR11BF01 模拟式二氧化氯传感器
CCS50-GR11BF01+ND 模拟式二氧化氯传感器
CCS50-AA11BF01+NA 模拟式二氧化氯传感器
CCS50-GR11AD01 模拟式二氧化氯传感器
CCS50-GR11BF03 模拟式二氧化氯传感器
CCS50-GR11AD03+NB 模拟式二氧化氯传感器
CCS50-AA11BF03+NB 模拟式二氧化氯传感器
CCS50-AA11BF01+ND 模拟式二氧化氯传感器
CCS50-GR11AD03 模拟式二氧化氯传感器
CCS50-GR11BF03+NA 模拟式二氧化氯传感器
CCS50-AA11AD03+ND 模拟式二氧化氯传感器
CCS50-AA11AD03 模拟式二氧化氯传感器
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Disinfection Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Disinfection.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Disinfection for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Disinfection Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Disinfection.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Disinfection for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Disinfection Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Disinfection.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Disinfection for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Disinfection Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Disinfection.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Disinfection for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.