Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

CM444 four channel transmitter

CM444 four channel transmitter

Liquiline CM444

Configurable Models 1 models
Scalable multi parameter field devices suitable for various industries
Compare

Analyser

Measuring Principle Potentiometric / ISE
Characteristic Robust plastic housing
All non-ex applications
Design 2 to 4x Memosens input, 2 to 8x current output
Alarmrelay, 4x relay, SD card for software update and copy & paste of setup
Process temperature -20 to 55 °C (0 to 130 °F)
Application Modular 4 wire controller
Multichannel: 1 to 4 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
4 sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Output / communication 2 to 8x 0/4 to 20 mA current outputs, alarmrelay,
4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet
Input 1 to 4x Memosens digital input
2x 0/4 to 20mA Input optional
2 to 4x Digital input optional

Conductivity

Measuring Principle Conductive
Application Modular 4 wire controller
Multichannel: 1 to 4 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
4 sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Characteristic Robust plastic housing
All non-ex applications
Design 2 to 4x Memosens input, 2 to 8x current output
Alarmrelay, 4x relay, SD card for software update and copy & paste of setup
Material Housing base: PC-FR
Housing seal: EPDM
Dimension 237 x 194 x 162 mm
9.33 x 7.64 x 6.38 inch
Process temperature -20 to 55 °C (0 to 130 °F)
Ingress protection IP66 / IP 67
Input 1 to 4x Memosens digital input
2x 0/4 to 20mA Input optional
2 to 4x Digital input optional
Output / communication 2 to 8x 0/4 to 20 mA current outputs, alarmrelay,
4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet
Certificates, declarations and approvals EAC, cCSAus

Disinfection

Measuring Principle Free chlorine
Application Modular 4 wire controller
Multichannel: 1 to 4 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
4 sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Characteristic Robust plastic housing
All non-ex applications
Design 2 to 4x Memosens input, 2 to 8x current output
Alarmrelay, 4x relay, SD card for software update and copy & paste of setup
Material Housing base: PC-FR
Housing seal: EPDM
Dimension 237 x 194 x 162 mm
9.33 x 7.64 x 6.38 inch
Process temperature -20 to 55 °C (0 to 130 °F)
Input 1 to 4x Memosens digital input
2x 0/4 to 20mA Input optional
2 to 4x Digital input optional
Output / communication 2 to 8x 0/4 to 20 mA current outputs, alarmrelay,
4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet
Certificates, declarations and approvals EAC, cCSAus

ORP / Redox

Measuring Principle Sensor ORP / Redox
Application Modular 4 wire controller
Multichannel: 1 to 4 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
4 sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Characteristic Robust plastic housing
All non-ex applications
Design 2 to 4x Memosens input, 2 to 8x current output
Alarmrelay, 4x relay, SD card for software update and copy & paste of setup
Material Housing base: PC-FR
Housing seal: EPDM
Dimension 237 x 194 x 162 mm
9.33 x 7.64 x 6.38 inch
Process temperature -20 to 55 °C (0 to 130 °F)
Ingress protection IP66 / IP 67
Input 1 to 4x Memosens digital input
2x 0/4 to 20mA Input optional
2 to 4x Digital input optional
Output / communication 2 to 8x 0/4 to 20 mA current outputs, alarmrelay,
4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet
Certificates, declarations and approvals EAC, cCSAus

Oxygen

Measuring Principle Amperometric oxygen measurement
Application Modular 4 wire controller
Multichannel: 1 to 4 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
4 sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Characteristic Robust plastic housing
All non-ex applications
Design 2 to 4x Memosens input, 2 to 8x current output
Alarmrelay, 4x relay, SD card for software update and copy & paste of setup
Material Housing base: PC-FR
Housing seal: EPDM
Dimension 237 x 194 x 162 mm
9.33 x 7.64 x 6.38 inch
Process temperature -20 to 55 °C (0 to 130 °F)
Input 1 to 4x Memosens digital input
2x 0/4 to 20mA Input optional
2 to 4x Digital input optional
Output / communication 2 to 8x 0/4 to 20 mA current outputs, alarmrelay,
4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Etherne
Certificates, declarations and approvals EAC, cCSAus

Sludge Level

Measuring Principle Ultrasonic sensor
Application Modular 4 wire controller
Multichannel: 1 to 4 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
4 sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Characteristic Robust plastic housing
All non-ex applications
Design 2 to 4x Memosens input, 2 to 8x current output
Alarmrelay, 4x relay, SD card for software update and copy & paste of setup
Material Housing base: PC-FR
Housing seal: EPDM
Dimension 237 x 194 x 162 mm
9.33 x 7.64 x 6.38 inch
Process temperature -20 to 55 °C (0 to 130 °F)
Ingress protection IP66 / IP 67
Input 1 to 4x Memosens digital input
2x 0/4 to 20mA Input optional
2 to 4x Digital input optional
Output / communication 2 to 8x 0/4 to 20 mA current outputs, alarmrelay,
4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet
Certificates, declarations and approvals EAC, cCSAus

Turbidity

Measuring Principle Single beam scattered light
Application Modular 4 wire controller
Multichannel: 1 to 4 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
4 sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Characteristic Robust plastic housing
All non-ex applications
Design 2 to 4x Memosens input, 2 to 8x current output
Alarmrelay, 4x relay, SD card for software update and copy & paste of setup
Material Housing base: PC-FR
Housing seal: EPDM
Dimension 237 x 194 x 162 mm
9.33 x 7.64 x 6.38 inch
Process temperature -20 to 55 °C (0 to 130 °F)
Ingress protection IP66 / IP 67
Input 1 to 4x Memosens digital input
2x 0/4 to 20mA Input optional
2 to 4x Digital input optional
Output / communication 2 to 8x 0/4 to 20 mA current outputs, alarmrelay,
4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet
Certificates, declarations and approvals EAC, cCSAus

pH

Measuring Principle Potentiometric
Application Modular 4 wire controller
Multichannel: 1 to 4 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
4 sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Characteristic Robust plastic housing
All non-ex applications
Design 2 to 4x Memosens input, 2 to 8x current output
Alarmrelay, 4x relay, SD card for software update and copy & paste of setup
Material Housing base: PC-FR
Housing seal: EPDM
Dimension 237 x 194 x 162 mm
9.33 x 7.64 x 6.38 inch
Process temperature -20 to 55 °C (0 to 130 °F)
Ingress protection IP66 / IP 67
Input 1 to 4x Memosens digital input
2x 0/4 to 20mA Input optional
2 to 4x Digital input optional
Output / communication 2 to 8x 0/4 to 20 mA current outputs, alarmrelay,
4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet
Certificates, declarations and approvals EAC, cCSAus

The Liquiline CM444 digital multi-parameter measuring transmitter is suitable for all kinds of process monitoring and control. Its modular structure is easy to expand. The four-channel controller enables seamless system integration, easy operation, reduced spare part storage and time and cost savings. The Liquiline CM444 offers first-class performance and ensures the highest process safety.

 

Advantages

Simple and flexible: one controller can be used for all parameter measurements, intuitive user interface, automatic sensor recognition, plug-and-play with pre-calibrated Memosens sensors

Strong adaptability: universal modules reduce spare part inventory and allow easy one-click expansion to an eight-channel measuring system at any time

Seamless system integration: unique combination of communication standards, suitable for various distributed control systems (DCS)

Simple and safe commissioning: communication with other devices via SD card, convenient setup, saving time and costs

Process control and safety: via the built-in web server, operators can remotely access diagnostic data and parameter settings, or access device parameters through any web browser - even via smartphone

 

Areas of application

The Liquiline CM444 multi-parameter transmitter is suitable for all non-hazardous areas, including the following industries and their utilities:

 

Food&beverage

Life sciences

Power&energy

Water&wastewater

Chemical industry

The Liquiline CM444 is compatible with all common communication protocols and interfaces, such as:

 

0/4...20 mA

HART

PROFIBUS DP

Modbus TCP / Modbus RS485

EtherNet/IP

Web server

 

 

E+H Product Configurator

Please enter the product order code to configure

Product comparison

Please enter the order codes of the products to compare in the boxes below (up to three products)

 

   

Technical documentation

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

A

Model Name
CM444-AAM41A5FF10BAA 四通道变送器
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Multi-parameter Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Multi-parameter.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Multi-parameter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Multi-parameter Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Multi-parameter.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Multi-parameter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Multi-parameter Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Multi-parameter.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Multi-parameter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Multi-parameter Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Multi-parameter.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Multi-parameter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.