Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

COS51D 溶解氧传感器

COS51D 溶解氧传感器

Oxymax W COS51D

Configurable Models 3 models
Oxymax COS51D is a reliable and highly accurate oxygen sensor for all kinds of water & wastewater applications (including hazardous areas). Designed to be low-maintenance with a long operating life, the sensor offers outstanding value for money. Oxymax COS51D is not the latest Memosens generation. To get information on the new Memosens COS51E sensor with extended functionality, click here.
Compare

Oxygen

Measuring Principle
Application Aeration tank, river monitoring, water treatment, fish farming, sewage treatment plants
Characteristic Amperometric 3-electrode longterm-stable sensor to measure dissolved oxygen
Measuring range 0.01 to 100 mg/l
0.00 to 1000 %SAT
0 to 2000 hPa
Measuring principle Closed membrane covered amperometric 3-electrode system
Design Digital signal transmission
Calibration datas stored in the sensor
Material Sensor body: POM
Membrane cap: POM
Dimension Diameter: 40mm (1.57 inch)
Shaft length: 144 mm (5.67 inch)
Process temperature -5 to 50 °C
(20 to 120 °F)
Process pressure max. 10 bar
(max. 145 psi)
Connection Memosens connector
Process: G1, NPT 3/4"

The Oxymax COS51D is a reliable, high-precision dissolved oxygen sensor for various water and wastewater applications (usable in hazardous areas). The low-maintenance design and long service life make the sensor economical to use. With Memosens digital technology, the Oxymax COS51D offers maximum process and data integrity combined with simple operation. Laboratory calibration and device pre-maintenance are possible.

 

Benefits

Highest measuring accuracy

Sensor load data logging for easy traceability

Intelligent self-monitoring sensor

Low calibration requirements; simple calibration in air is sufficient

Long maintenance intervals

Explosion-proof version, can be used in hazardous areas

 

Application areas

The Oxymax COS51D is used for dissolved oxygen concentration measurement:

 

Wastewater treatment plants:

- O2 aeration basin control

- Process water treatment and monitoring; waterworks:

- Drinking water condition monitoring (oxygen enrichment, corrosion protection, etc.)

- Water quality monitoring of rivers, lakes or seawater

Utilities:

- O2 biological treatment control

- Process water treatment and monitoring

Suitable for hazardous areas (ATEX, FM, CSA).

 

 

E+H product model configurator

Please enter the product model to configure

Product comparison

Please enter the product models to be compared in the input boxes below; up to three products can be compared

 

 

   

Technical information

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

A

   

Measuring principle video

Source: public information from the Endress+Hauser website

Model Name
COS51D-AS800 溶解氧传感器
COS51D-GS800 溶解氧传感器
COS51D-GS810 溶解氧传感器
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Dissolved Oxygen Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Dissolved Oxygen.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Dissolved Oxygen for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Dissolved Oxygen Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Dissolved Oxygen.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Dissolved Oxygen for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Dissolved Oxygen Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Dissolved Oxygen.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Dissolved Oxygen for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Dissolved Oxygen Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Dissolved Oxygen.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Dissolved Oxygen for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.