Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

CPA875 伸缩式支架

CPA875  伸缩式支架

Cleanfit CPA875

Completely sterilizable, the Cleanfit CPA875 retractable assembly guarantees maximum protection from contamination making it ideal for use in life science and food & beverage applications. Fully certified (EHEDG and ASME BPE) and made of FDA-recommended materials, the CPA875 is the right choice where hygiene counts!
Compare

Oxygen

Measuring Principle Sensor ORP / Redox
Application Food and beverages, biotechnology, life sciences, special chemicals
Installation Retractable process assembly
Characteristic Open and closed tanks, piping
Design Sterile and hygienic stile
Manual or pneumatic
Material Holder: stainless steel 1.4435
Seals: EPDM-FDA, FKM-FDA, FFKM-FDA
Dimension Immersion depth: 16.1 to 81.4 mm (0.63 to 3.20 inch), depending on process adaption
Process temperature -10 to 140 °C (14 to 284 °F)
Process pressure Pneumatic drive: 16 bar up to 140 °C (232 psi up to 284 °F)
Manual drive: 8 bar up to 140 °C (116 psi up to 284 °F)
Connection Aseptic DN25 clampable, Aseptic DN50 screw-in, Clamp ISO 2852, ASME BPE, Varivent N

pH

Measuring Principle Potentiometric
Application Food and beverages, biotechnology, life sciences, special chemicals
Installation Retractable process assembly
Characteristic Open and closed tanks, piping
Design Sterile and hygienic stile
Manual or pneumatic
Material Holder: stainless steel 1.4435
Seals: EPDM-FDA, FKM-FDA, FFKM-FDA
Dimension Immersion depth: 16.1 to 81.4 mm (0.63 to 3.20 inch), depending on process adaption
Process temperature -10 to 140 °C (14 to 284 °F)
Process pressure Pneumatic drive: 16 bar up to 140 °C (232 psi up to 284 °F)
Manual drive: 8 bar up to 140 °C (116 psi up to 284 °F)
Connection Aseptic DN25 clampable, Aseptic DN50 screw-in, Clamp ISO 2852, ASME BPE, Varivent N

Completely sterile, the Cleanfit CPA875 retractable assembly ensures the highest contamination protection, making it the ideal choice for life sciences, food and beverage applications. With all approvals (EHEDG and ASME BPE) and FDA-listed materials, the CPA875 is the right choice for hygienic applications!

 

Benefits

Highest process safety: the patented dynamic seal design prevents contamination.

Simple operation: sensor removal, sterilization and calibration in the process – corrosion-resistant and hygienically safe.

No cross-contamination: sterile design complies with EHEDG and ASME BPE, and the sealing system complies with FDA and USP Cl. VI.

Flexible: various process connections to meet diverse process connection requirements.

Optional double service chamber: the seal between sterile and non-sterile parts moves dynamically along the sensor tube – like a syringe. The sterile space and the process medium never come into contact.

 

Application areas

The Cleanfit CPA875 is a retractable assembly for installing pH electrodes, ORP electrodes, dissolved oxygen sensors and NIR sensors with a diameter of 12 mm and lengths of 225/360 mm.

 

Its design offers the highest safety in the following industries:

 

Food and Beverage

Biotechnology

Life sciences

Specialty chemicals

 

 

E+H product model configurator

Please enter the product model to configure

Product comparison

Please enter the product models to be compared in the input boxes below; up to three products can be compared

 

   

Technical information

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

   

Measuring principle video

Source: public information from the Endress+Hauser website

Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Brackets Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Brackets.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Brackets for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Brackets Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Brackets.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Brackets for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Brackets Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Brackets.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Brackets for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Brackets Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Brackets.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Brackets for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.