Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

CPF82 Analog ORP sensor

CPF82 Analog ORP sensor

Orbipac CPF82

Configurable Models 4 models
Compact electrode for wastewater, primaries and metal
Compare

ORP / Redox

Measuring Principle Sensor ORP / Redox
Application Water, waste water, process, galvanic
Characteristic Resistent against electrolyte poisoning and dirt repellent gel-electrode including process connection NPT 3/4".
Measuring range -1500mV - -1500mV
Measuring principle Gel-compact electrode with double chamber reference system, potassium nitrate bridge electrolyte and PTFE-diaphragm, platinum pin
Design Compact electrode in PPS housing with NPT3/4" process connection.
Material PPS / glass / PTFE, platinum
Dimension Length: 120´mm
(4.68 inch)
Process temperature -10°C - 110°C
(14°F - 230°F)
Process pressure max. 10 bar
(145 psi)
Connection TOP68 connection head
Ingress protection IP68

Field of application
Orbipac CPF82 is the analog simple solution for ORP measurement in harsh environments. Its large, dirt-repellent PTFE diaphragm guarantees low maintenance while its integrated assembly saves space and time during flow or immersion installation.
Orbipac CPF82 is the robust ORP sensor for treatment of industrial water and wastewater and for processes in mining industries. It monitors:
Inlet and outlet
Neutralization
Flotation
Leaching

Benefits
Suitable for flow and immersion installation
Long-time stable: Second electrolyte bridge for better protection against electrode poisoning ions such as S2- or CN- ions
Robust polymer housing protects against mechanical damage

ORP / Redox: Measuring Principle Sensor ORP / Redox Application Water, waste water, process, galvanic Characteristic Resistent against electrolyte poisoning and dirt repellent gel-electrode including process connection NPT 3/4". Measuring range -1500mV - -1500mV Measuring principle Gel-compact electrode with double chamber reference system, potassium nitrate bridge electrolyte and PTFE-diaphragm, platinum pin Design Compact electrode in PPS housing with NPT3/4" process connection. Material PPS / glass / PTFE, platinum Dimension Length: 120´mm (4.68 inch) Process temperature -10°C - 110°C (14°F - 230°F) Process pressure max. 10 bar (145 psi) Connection TOP68 connection head Ingress protection IP68

 

ORP / Redox:

Measuring Principle Sensor ORP / Redox
Application Water, waste water, process, galvanic
Characteristic Resistent against electrolyte poisoning and dirt repellent gel-electrode including process connection NPT 3/4".
Measuring range -1500mV - -1500mV
Measuring principle Gel-compact electrode with double chamber reference system, potassium nitrate bridge electrolyte and PTFE-diaphragm, platinum pin
Design Compact electrode in PPS housing with NPT3/4" process connection.
Material PPS / glass / PTFE, platinum
Dimension Length: 120´mm
(4.68 inch)
Process temperature -10°C - 110°C
(14°F - 230°F)
Process pressure max. 10 bar
(145 psi)
Connection TOP68 connection head
Ingress protection IP68
Model Name
CPF82-PA11A2 ORP电极
CPF82-PA11A3 ORP电极
CPF82-PA11B2 ORP电极
CPF82-PA11A4 ORP电极
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · ORP Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of ORP.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable ORP for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · ORP Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of ORP.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable ORP for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · ORP Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of ORP.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable ORP for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · ORP Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of ORP.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable ORP for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.