Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

CPM253 PH/ORP变送器

CPM253  PH/ORP变送器

Liquisys M CPM253

Configurable Models 20 models
Liquisys CPM253 is a standard pH/ORP transmitter for all analog and digital Memosens sensors. It improves your operational safety thanks to continuous plausibility, process and sensor checks. Select from numerous hardware and software modules, such as relays or fieldbus communication, to adapt it exactly to your measuring task. This modularity also allows you to upgrade the transmitter at any time. A simple menu and two-point calibration make configuration and operation fast and easy.
Compare

ORP / Redox

Measuring Principle Sensor ORP / Redox
Application Water, waste water, process
Characteristic 4-wire transmitter
Design pH/ORP-field housing made of PC/ABS
Material PC/ABS-housing
Dimension 247x170x115mm
Temperature sensor Display and current output
Ex certification No
Ingress protection No
Input One-channel-transmitter
Output / communication 0/4-20mA, Hart, Profibus.
Certificates, declarations and approvals CSA Gen. Purpose.

pH

Measuring Principle Potentiometric
Application Water, waste water, process
Characteristic 4-wire transmitter
Design pH/ORP field housing made of PC/ABS
Material PC/ABS housing
Dimension 247x170x115mm
(9.63x6.63x4.48inch)
Temperature sensor Display and current output
Ex certification No
Ingress protection No
Input One-channel-transmitter
Output / communication 0/4-20 mA, Hart, Profibus
Certificates, declarations and approvals CSA Gen. purpose

The Liquisys CPM253 is a standard pH/ORP transmitter for analog and digital Memosens sensors. Thanks to continuous plausibility checks and checks of the measuring process and the sensor, it increases operating safety. Whichever hardware and software modules are selected, e.g. relays and bus communication, it adapts perfectly to the measuring task. It also allows the transmitter to be upgraded at any time, and its simple menus and factory calibration make configuration and operation fast and convenient.

 

Benefits

Higher operating safety: continuous process check system, user-defined alarm settings and an optimized Memosens interface for reliable sensor connection.

Reliable self-monitoring: sensor check system for pH electrode calibration and calibration plausibility check.

Easy to operate and maintain: intuitive user interface, precalibrated Memosens sensors with hot plug support and direct manual contact control.

Reduced maintenance effort: automatic cleaning triggered by alarms or limit switches (using Chemoclean).

Suitable for a wide range of applications: various extension options, such as P(ID) controllers, timers, etc., for flexible use in all processes.

 

Application areas

The Liquisys CPM253 transmitter can be used with all pH/ORP glass electrodes and ISFET electrodes in non-hazardous areas, and is suitable for the following industries and applications:

 

Chemical

Food & Beverage

Power & Energy

Water and wastewater

Primary raw materials and metallurgy

The Liquisys CPM253 has the following protocols and interfaces:

 

0/4...20 mA

HART

PROFIBUS DP

PROFIBUS PA

 

 

E+H product model configurator

Please enter the product model to configure

Product comparison

Please enter the product models to be compared in the input boxes below; up to three products can be compared

 

   

Technical information

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

A

Source: public information from the Endress+Hauser website

Model Name
CPM253-PR0005 PH/ORP变送器
CPM253-MR0105 PH/ORP变送器
CPM253-MR8005 PH/ORP变送器
CPM253-MR0005 PH/ORP变送器
CPM253-PR8005 PH/ORP变送器
CPM253-PR0105 PH/ORP变送器
CPM253-PR0620 PH/ORP变送器
CPM253-PS8510 PH/ORP变送器
CPM253-IS8615 PH/ORP变送器
CPM253-MR0505 PH/ORP变送器
CPM253-IS0010 PH/ORP变送器
CPM253-MR0010 PH/ORP变送器
CPM253-PS0125 PH/ORP变送器
CPM253-PS0116 PH/ORP变送器
CPM253-MR0605 PH/ORP变送器
CPM253-MR0615 PH/ORP变送器
CPM253-MR0610 PH/ORP变送器
CPM253-IS0005 PH/ORP变送器
CPM253-MS0405 PH/ORP变送器
CPM253-MS0005 PH/ORP变送器
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · pH Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of pH.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable pH for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · pH Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of pH.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable pH for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · pH Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of pH.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable pH for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · pH Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of pH.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable pH for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.