Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

Sampling bracket CSA420

Sampling bracket CSA420

Sampling bracket CSA420

Installation bracket, suitable for sampling in process applications
Compare

Watersampler

Measuring Principle Sampler
Functions Pneumatic sampling assembly
Application sampling from pressurized pipes
Dosing system fixed sample volume 10, 30, or 50 ml
Installation process connection Triclamp 2" or flange DN50
Process temperature 0 - 50°C
Process pressure up to 6 bar
Material plunger PP; housing Polyamid PA
plunger 1.4404/316L; housing Polyamid PA
plunger 1.4404/316L; housing 316Ti
Dimension lenght 381 mm x diameter 75 mm
Weight dependent on version 1,55 kg to 6,1 kg
Options optional cleaning valve

The Samplefit CSA420 allows samples to be taken directly from pressurized pipes. Designed with short sampling intervals, it provides samples that accurately represent the medium composition, ensuring precise process control. The small sample volume minimizes product loss and thus improves process efficiency.

Benefits
Accurately represents the medium composition thanks to the short sampling intervals
Small sample volume minimizes the loss of valuable media
Optional cleaning valve, no cross-contamination
Different equipment and material options to optimize the application

Applications
For process measurement in the following industries:
Wastewater
Analysis stations
Surface water monitoring
Drinking water

 

E+H Product Model Configuration Tool

Please enter the product model to configure

Product comparison

Please enter the product models to compare in the fields below; up to three products can be compared

 

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

A

A

Source: Endress+Hauserpublic information from the website

Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · EH-ONLINE Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of EH-ONLINE.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable EH-ONLINE for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · EH-ONLINE Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of EH-ONLINE.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable EH-ONLINE for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · EH-ONLINE Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of EH-ONLINE.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable EH-ONLINE for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · EH-ONLINE Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of EH-ONLINE.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable EH-ONLINE for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.