CYA10 安装支架

CYA10 安装支架

Dipfit CYA10

CYA10 浸入式安装支架,适合污水、地表水和工业应用
Compare

Conductivity

Measuring Principle Conductive
Application Monitoring ground water, surface water or wastewater.
Installation Fixed installation
Characteristic Installation into tanks, sewers, wells, basins, channels or rivers.
Design Immersion assembly with flexible body (hose).
Material Poly ethylene (PE)
Process pressure Max. 4 bar (relative)
Connection Flange DN50, Flange 2", Chain bracket, Thread

ORP / Redox

Measuring Principle Sensor ORP / Redox
Application Monitoring ground water, surface water or wastewater.
Installation Fixed installation
Characteristic Installation into tanks, sewers, wells, basins, channels or rivers.
Design Immersion assembly with flexible body (hose).
Material Poly ethylene (PE)
Process pressure Max. 4 bar (relative)
Connection Flange DN50, Flange 2", Chain bracket, Thread

Oxygen

Measuring Principle Amperometric oxygen measurement
Application Monitoring ground water, surface water or wastewater.
Installation Fixed installation
Characteristic Installation into tanks, sewers, wells, basins, channels or rivers.
Design Immersion assembly with flexible body (hose).
Material Poly ethylene (PE)
Process pressure Max. 4 bar (relative)
Connection Flange DN50, Flange 2", Chain bracket, Thread

pH

Measuring Principle Potentiometric
Application Monitoring ground water, surface water or wastewater.
Installation Fixed installation
Characteristic Installation into tanks, sewers, wells, basins, channels or rivers.
Design Immersion assembly with flexible body (hose).
Material Poly ethylene (PE)
Process pressure Max. 4 bar (relative)
Connection Flange DN50, Flange 2", Chain bracket, Thread

CYA10 immersion mounting assembly for wastewater, surface water and industrial applications

Advantages
• Various installation options (fixing via flange connection or in combination with Flexdip CYH112) allow easy installation in shafts, rivers and boilers without tools
• The flexible hose of the holder makes sensor handling easy and saves maintenance time at the measuring point even at large immersion depths
• The compact design of the holder, used with PG13.5 sensors (diameter “12 mm”), facilitates measuring point installation and allows installation in pipes/
channels, boilers, sewer pipes or manholes
• Measuring points can be installed and operated in wastewater drains, covered basins and hazardous areas, offering outstanding application flexibility

Application
The CYA10 immersion assembly has a maximum insertion depth of 10 meters and is used in the following applications:
• Monitoring of surface water (groundwater wells and rivers) as well as brackish water and seawater
• Wastewater treatment
• Utilities
The Dipfit CYA10 is compatible with all Memosens digital sensors with a diameter of 12 mm (no liquid KCl electrolyte) and can measure the following parameters:
• pH/ORP
• Conductivity
• Dissolved oxygen

 

 

E+H product configurator

Please enter the product order code to configure

Product comparison

Please enter the order codes of the products you wish to compare in the fields below (up to three products)

 

Technical documentation

   

Technical data

 

 

   

Documents/Manuals/Software

 

 

   

Accessories/Spare parts

 

 

Source:Endress+Hauserpublic information from the website

Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Process Measuring and Control Instrument Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Process Measuring and Control Instrument.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Process Measuring and Control Instrument for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Data Manager Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Data Manager.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Data Manager for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Power Supplies and Safety Barriers Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Power Supplies and Safety Barriers.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Power Supplies and Safety Barriers for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Gateways and Modems Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Gateways and Modems.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Gateways and Modems for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.