CompareConductivity
| Measuring Principle | Conductive |
| Application | Laboratory measuring cable for contactless, inductive, digital transmission of measurement signals |
| Installation | Inductive plug-head for digital sensors with Memosens technology and M8 or M12 plug to connect to the transmitter. |
| Characteristic | Inductive, digital transmission of measurement signals and energy. Not influenced by moisture, EMC-field and corrosion. |
| Design | Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head. No open contacts, resistant against huminity. |
| Dimension | Diameter: 4.5 mm ( 0.18" ) Cores: 2x2 cores, twisted paires Length: 1.5 m +3 m (4.9 ft+ 9.8 ft ) |
| Ex certification | IECEX EX ia II C T6 Ga ATEX EX II 1G Ex ia II C T6 Ga |
| Ingress protection | IP65 |
Oxygen
| Measuring Principle | Amperometric oxygen measurement |
| Application | Laboratory measuring cable for contactless, inductive, digital transmission of measurement signals |
| Installation | Inductive plug-head for digital sensors with Memosens technology and M8 or M12 plug to connect to the transmitter. |
| Characteristic | Inductive, digital transmission of measurement signals and energy. Not influenced by moisture, EMC-field and corrosion. |
| Design | Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head. No open contacts, resistant against huminity. |
| Dimension | Diameter: 4.5 mm ( 0.18" ) Cores: 2x2 cores, twisted paires Length: 1.5 m +3 m (4.9 ft+ 9.8 ft ) |
| Ex certification | IECEX EX ia II C T6 Ga ATEX EX II 1G Ex ia II C T6 Ga |
| Connection | IP65 |
pH
| Measuring Principle | Potentiometric |
| Application | Laboratory Measuring cable for contactless, inductive, digital transmission of measurement signals |
| Installation | Inductive plug-head for digital sensors with Memosens technology and M8 or M12 plug to connect to the transmitter. |
| Characteristic | Inductive, digital transmission of measurement signals and energy. Not influenced by moisture, EMC-field and corrosion. |
| Design | Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head. No open contacts, resistant against huminity. |
| Material | PEEK / TPE |
| Dimension | Diameter: 4.5 mm ( 0.18" ) Cores: 2x2 cores, twisted paires Length: 1.5 m +3 m (4.9 ft+ 9.8 ft ) |
| Ex certification | IECEX EX ia II C T6 Ga ATEX EX II 1G Ex ia II C T6 Ga |
| Ingress protection | IP 65 |
The CYK20 is a flexible data cable that reliably connects Memosens sensors to the Memobase Plus sensor software and the Liquiline To Go portable transmitter. It provides a fully waterproof connection with an inductive coupling, free of contact corrosion and easy to use. It enables safe and reliable signal transmission without contact corrosion or potential interference.
Advantages
Unique design for laboratory applications: flexible, easy to operate, fast connection of sensors for various parameters
Non-contact inductive digital signal transmission for the highest process safety: no contact corrosion, fully waterproof, no potential interference
Hazardous area approval
Areas of application
The CYK20 is a Memosens data cable used in laboratories in all industries. Suitable for the following parameters:
pH/ORP
Dissolved oxygen (membrane method)
Conductive conductivity
Disinfection
All electrodes with Memosens plug can be connected to:
Memobase Plus CYZ71D software (Memolink)
Liquiline To Go CYM290/CYM291 portable transmitter
International explosion protection approvals such as ATEX and IECEx; the cable can be used in hazardous areas.
E+H Product Configurator
Please enter the product order code to configure
Product comparison
Please enter the order codes of the products to compare in the boxes below (up to three products)
Technical documentation
Technical data
Documents/Manuals/Software
Accessories/Spare parts
Measuring principle video
Case Studies
Municipal Wastewater Treatment — Wastewater Treatment Plant · EH-Lab Application Case
Project Background
Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of EH-Lab.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable EH-Lab for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage — Food Production Line · EH-Lab Application Case
Project Background
Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of EH-Lab.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable EH-Lab for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical — Reactors and Storage Tanks · EH-Lab Application Case
Project Background
Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of EH-Lab.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable EH-Lab for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy — Power Plant Boiler and Turbine · EH-Lab Application Case
Project Background
Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of EH-Lab.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable EH-Lab for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Related Products
Endress+HauserLiquiline To Go CYM290
Endress+HauserLiquiline Mobile CML18
Endress+HauserLiquiline To Go Ex CYM291
Endress+HauserMemosens CPL51E
Endress+HauserTurbimax CUE25, Handheld Infrared
Endress+HauserTurbimax CUE23, Laboratory Infrared
Endress+HauserZero-point gel COY8