Technical Data
CompareConductivity
| Measuring Principle | Conductive |
| Application | Simulation of freely configurable values for qualification of digital data transmission of analysis measuring points with Memosens protocol Multiparameter, main- and secondary values |
| Installation | Temporary connection via Memosens cable with inductive coupling |
| Measuring range | Ranges like the simulated sensors |
| Dimension | Handheld: 94 x 236 x 25 to 40 mm 3.7 x 9.29 x 0.98 to 1.57 inch |
| Process temperature | Umgebungstemperatur: –20 to 50 °C (–4 to 120 °F) |
| Ex certification | ATEX, IECEx, CSA |
| Connection | Battery powered |
| Ingress protection | IP65 |
Disinfection
| Measuring Principle | Free chlorine |
| Application | Simulation of freely configurable values for qualification of digital data transmission of analysis measuring points with Memosens protocol Multiparameter, main- and secondary values |
| Measuring range | Ranges like the simulated sensors |
| Dimension | Handheld: 94 x 236 x 25 to 40 mm 3.7 x 9.29 x 0.98 to 1.57 inch |
| Process temperature | Ambient temperature: –20 to 50 °C (–4 to 120 °F) |
| Connection | Battery powered |
ORP / Redox
| Measuring Principle | Sensor ORP / Redox |
| Application | Simulation of freely configurable values for qualification of digital data transmission of analysis measuring points with Memosens protocol Multiparameter, main- and secondary values |
| Installation | Temporary connection via Memosens cable with inductive coupling |
| Measuring range | Ranges like the simulated sensors |
| Dimension | Handheld: 94 x 236 x 25 to 40 mm 3.7 x 9.29 x 0.98 to 1.57 inch |
| Process temperature | Ambient temperature: –20 to 50 °C (–4 to 120 °F) |
| Ex certification | ATEX, IECEx, CSA |
| Connection | Battery powered |
| Ingress protection | IP65 |
Oxygen
| Measuring Principle | Amperometric oxygen measurement |
| Application | Simulation of freely configurable values for qualification of digital data transmission of analysis measuring points with Memosens protocol Multiparameter, main- and secondary values |
| Installation | Temporary connection via Memosens cable with inductive coupling |
| Measuring range | Ranges like the simulated sensors |
| Dimension | Handheld: 94 x 236 x 25 to 40 mm 3.7 x 9.29 x 0.98 to 1.57 inch |
| Process temperature | Ambient temperature: –20 to 50 °C (–4 to 120 °F) |
| Ex certification | ATEX: Ex ia, zone 0 |
| Connection | Battery powered |
| Ingress protection | IP65 |
Turbidity
| Measuring Principle | Single beam scattered light |
| Application | Simulation of freely configurable values for qualification of digital data transmission of analysis measuring points with Memosens protocol. Multiparameter, main- and secondary values |
| Installation | Temporary connection via Memosens cable with inductive coupling. |
| Measuring range | Ranges like the simulated sensors. |
| Dimension | Handheld, 9,5 x 23,5 x 3,5 cm |
| Process temperature | -20...55°C ambient temperature |
| Ex certification | ATEX: Ex ia, zone 1 |
| Connection | Battery powered |
| Ingress protection | IP65 |
pH
| Measuring Principle | Potentiometric |
| Application | Simulation of freely configurable values for qualification of digital data transmission of analysis measuring points with Memosens protocol Multiparameter, main- and secondary values |
| Installation | Temporary connection via Memosens cable with inductive coupling |
| Measuring range | Ranges like the simulated sensors |
| Dimension | Handheld: 94 x 236 x 40 mm 3.7 x 9.29 x 1.57 inch |
| Process temperature | Ambient temperature: –20 to 50 °C (–4 to 120 °F) |
| Ex certification | ATEX, IECEx, CSA |
| Connection | Battery powered |
| Ingress protection | IP65 |
Memocheck Sim CYP03D is a flexible service and certification tool for all applications. It simulates definable values to support your installation, debugging, and troubleshooting. Memocheck Sim can replace the sensor, check the complete measurement loop from the cable connector to the process control system, and verify that the transmission of the measured value is zero error. The Memocheck Sim with quality certification is selected to certify the entire measuring point.
advantage
Fast and reliable function check: freely definable measured values and amplitudes for flexibility in installation, commissioning, troubleshooting and factory certification
Suitable for controlled environments: Quality certification and traceable calibration certificates are available
Improve the safety of the measuring loop: check the complete measuring loop from the cable connector to the process control system
All parameters available in one tool: pH, ORP, conductivity, dissolved oxygen, residual chlorine, turbidity and nitrate and SAC
Explosion-proof certified for use in explosion-hazardous areas
Application areas
Factory Certification
Installation and commissioning
fault diagnosis
technical parameters
Documentation/Manuals/Software
Accessories/Spare Parts
Source:Endress Hauserwebsite public information
Case Studies
Municipal Wastewater Treatment — Wastewater Treatment Plant · Multi-parameter Application Case
Project Background
Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Multi-parameter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Multi-parameter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage — Food Production Line · Multi-parameter Application Case
Project Background
Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Multi-parameter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Multi-parameter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical — Reactors and Storage Tanks · Multi-parameter Application Case
Project Background
Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Multi-parameter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Multi-parameter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy — Power Plant Boiler and Turbine · Multi-parameter Application Case
Project Background
Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Multi-parameter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Multi-parameter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Related Products
Endress+HauserLiquiline CM442
Endress+HauserLiquiline M CM42
Endress+HauserLiquiline CM14
Endress+HauserLiquiline Compact CM82
Endress+HauserLiquiline CM44P
Endress+HauserLiquiline CM442R
Endress+Hauser多参数变送器
Endress+Hauser