| Measuring Principle | Level radar |
| Characteristic / Application | For common non-contact continuous level measurement in liquids, especially suited for small process connections and for chemically aggressive media; Rod antenna with PTFE coating |
| Specialities | Heartbeat Technology, SIL 2 according to IEC 61508, Bluetooth® commissioning, Operation and maintenance SmartBlue App, Safety and reliability with Multi-Echo Tracking, HistoROM, RFID TAG for easy identification |
| Supply / Communication | 2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus) 4-wire (HART) Bluetooth® wireless technology and App (optional) |
| Frequency | C-band (~6 GHz) |
| Accuracy | +/- 6 mm (0.24 in) |
| Ambient temperature | -40...+80 °C (-40...+176 °F) |
| Process temperature | -40...+150 °C (-40...+302 °F) |
| Process pressure / max. overpressure limit | Vacuum...40 bar (Vacuum...580 psi) |
| Main wetted parts | PTFE, PVDF |
| Process connection | Thread: MNPT 1 1/2, R 1 1/2 Flange: DN50...DN150, ASME 2"...6", JIS 10K |
| Max. measurement distance | Standard: 20 m (66 ft) |
| Communication | 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus Bluetooth® wireless technology |
| Certificates / Approvals | ATEX, FM, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, KC, EAC, UK Ex |
| Safety approvals | Overfill protection WHG SIL |
| Design approvals | EN 10204-3.1 ASME B31.3 AD2000 |
| Options | Display, Remote operation via SmartBlue App using Bluetooth®, Customized parameterization, Gas-tight feed through, PWIS free |
| Application limits | Maximum measuring range is dependent on the tank form and/or application Nozzle height >250 mm: FMR51, FMR52, FMR54 Low DK: FMR51, FMR52, FMR54 |
Micropilot FMR53 is suitable for level measurement under simple conditions; its rod antenna is particularly suitable for small process connections. The antenna and flange with PTFE coating are highly corrosion-resistant. Micropilot FMR53 is used for continuous, non-contact level measurement of liquids, pastes and slurries. The measurement is unaffected by changes in the medium, temperature changes, gas phase or vapor.
Benefits
Stable and reliable measurement, unaffected by changes in the medium and process conditions
HistoROM integrated data storage unit for fast commissioning, maintenance and diagnostics
High measurement reliability based on multi-echo tracking, ensuring accurate measurement even with obstacles in the vessel
Hardware and software developed in accordance with IEC 61508; a single device meets SIL2, and SIL3 under homogeneous redundancy
Heartbeat Technology for efficient and safe plant operation throughout the entire life cycle
Seamless integration into control or asset management systems, intuitive menu-guided operating concept (on site or via the control system)
Certified by world-leading SIL and WHG tests, saving time and money
Application
Particularly suitable for small process connections; the PTFE sensor can be used for chemically corrosive media.
Process connection: 1½" thread or flange
Temperature range: -40 to +150°C (–40 to +302°F)
Pressure range: -1 to +40 bar (–14.5 to +580 psi)
Maximum measuring range: 20 m (66 ft)
Accuracy: ±6 mm
C-band: 6 GHz
International explosion protection approvals, WHG overflow protection, SIL, 5-point linearity protocol
E+H Product Configurator
Please enter the product model to configure
Product Comparison
Please enter the product models to compare in the fields below. Up to three products can be compared
Technical Documentation
Technical Specifications
Documents/Manuals/Software
Accessories/Spare Parts
Measuring Principle Video
Source:Endress+Hauserwebsite public information
Case Studies
Municipal Wastewater Treatment — Wastewater Treatment Plant · Radar Application Case
Project Background
Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Radar.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Radar for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage — Food Production Line · Radar Application Case
Project Background
Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Radar.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Radar for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical — Reactors and Storage Tanks · Radar Application Case
Project Background
Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Radar.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Radar for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy — Power Plant Boiler and Turbine · Radar Application Case
Project Background
Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Radar.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Radar for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Related Products
Endress+HauserMicropilot FMR20
Endress+HauserMicropilot FMR10
Endress+HauserMicropilot FMR56
Endress+HauserMicropilot FMR50
Endress+HauserMicropilot FMR52
Endress+HauserMicropilot FMR60
Endress+HauserMicropilot FMR57
Endress+Hauser